WATER RECIRCULATION PUMP

RESERVOIR DRAIN PUMPWARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

WATER RECIRCULATION PUMP

RESERVOIR DRAIN PUMP

Refer to page 4-7 for the procedure for access- ing the water recirculation pump.

1.Unplug ice maker or disconnect power.

2.Set the ohmmeter to the appropriate scale.

3.Touch the ohmmeter test leads to the outside water recirculation pump wire connector pins. The meter should indicate approximately 3.6 ohms.

Refer to page 4-8 for the procedure for access- ing the reservoir drain pump.

1.Unplug ice maker or disconnect power.

2.Set the ohmmeter to the appropriate scale.

3.Touch the ohmmeter test leads to the outside reservoir drain pump wire con- nector pins. The meter should indicate approximately 3.6 ohms.