WATER RECIRCULATION PUMP | RESERVOIR DRAIN PUMP |
Refer to page
1.Unplug ice maker or disconnect power.
2.Set the ohmmeter to the appropriate scale.
3.Touch the ohmmeter test leads to the outside water recirculation pump wire connector pins. The meter should indicate approximately 3.6 ohms.
Refer to page
1.Unplug ice maker or disconnect power.
2.Set the ohmmeter to the appropriate scale.
3.Touch the ohmmeter test leads to the outside reservoir drain pump wire con- nector pins. The meter should indicate approximately 3.6 ohms.