Whirlpool KUIA15PRL*11, KUIA18NNJ*11, KUIA15NRH*11 manual Water Level Sensor, Condenser Fan Motor

Models: KUIA15PLL*11 KUIA18PNL*11 KUIA15NLH*11 KUIA15PRL*11 KUIA15NRH*11 KUIA18NNJ*11

1 74
Download 74 pages 21.98 Kb
Page 50
Image 50
WATER LEVEL SENSOR

CONDENSER FAN MOTORWARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

WATER LEVEL SENSOR

CONDENSER FAN MOTOR

Refer to page 4-8 for the procedure for access- ing the water level sensor.

1.Run the diagnostic tests (see page 3-7) and check for the proper operation of the water level sensor. in step 4b.

2.With the water level sensor immersed in water the Service LED should stay on solid.

3.With the water level sensor out of the water the Service LED should blink.

Refer to page 4-8 for the procedure for access- ing the condenser fan motor.

1.Run the diagnostic tests (see page 3-7) and check for the proper operation of the condenser fan motor in step 7.

NOTE: During operation, 120 volts will be present at the condenser fan motor electrical connector.

5-4

Page 50
Image 50
Whirlpool KUIA15PRL*11 Water Level Sensor, Condenser Fan Motor, Electrical Shock Hazard Disconnect power before servicing