REMOVING THE COMPRESSOR
WARNING
Electrical Shock Hazard Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1.Unplug ice maker or disconnect power.
2.Open the ice maker door.
3.Remove the ice from the storage bin.
4.Disconnect the water and drain lines from the ice maker and remove the unit from its installation.
5.At the rear of the unit, remove the four screws from the unit compartment cover and remove the cover.
Unit Compartment Cover
4 Screws
6.Remove the terminal cover using a stan- dard screwdriver. Insert the screwdriver into the cover slot, and press down to unsnap and remove it.
Compressor
Terminal Cover
Cover Slot
7.Remove the wires from the ground termi- nal, the overload protector terminal, and the relay terminal.
8.Pull the overload protector and relay from the compressor pins.
Ground Wire
Overload
Protector
Relay
Continued on the next page.