TROUBLESHOOTING CHART

P roblem

P robable C aus e

T es t P roc edure-Ac tion

 

 

 

 

No power at wall outlet

C heck circuit

 

breaker/fus es

 

 

 

No power at

C heck for kinked drain

 

hose, blocked screen or

 

auxilary drain

 

blocked vent outlet or

 

pump power outlet

 

 

hose.

 

Disconnected

Reconnect and check for

 

selector switch

proper operation.

 

 

 

W ill not run

Loose connections

 

at selector switch

R epair connections

 

 

or control board

 

 

No power through

C heck continuity of power

 

power cord

cord and replace if open

 

 

 

 

R oom temperature

B in thermistor has unit

 

shut off C ustomer

 

below 55°F (13°C )

 

Instruction

 

 

 

 

 

 

Ice touching bin

Normal operation

 

thermistor

 

 

 

W ater supply turned

Turn on water supply

 

off

 

 

 

Loose or missing

Tighten or replace

 

reservoir cap

 

 

 

 

 

 

W ater slide return tube

R eposition tube

 

out of reservoir

W ill not make ice

 

 

 

Inlet tube out of

 

W ater reservoir is

 

position and missing

R eposition tube

empty

reservoir

 

E vaporator is cold

 

W ater inlet tube frozen

 

with thin or no ice

Thaw and reposition tube

slab

near evaporator

 

Defective inlet water

Test and repair or replace

 

 

valve

 

 

An ice slab only

Look for interference with

 

partially released from

 

cutter grid and clean the

 

evaporator and water

evaporator plate (see

 

was bridged down into

 

procedure on page 8-1)

 

the bin

 

 