TROUBLESHOOTING CHART
P roblem | P robable C aus e | T es t P roc | |
|
|
| |
| No power at wall outlet | C heck circuit | |
| breaker/fus es | ||
|
| ||
| No power at | C heck for kinked drain | |
| hose, blocked screen or | ||
| auxilary drain | ||
| blocked vent outlet or | ||
| pump power outlet | ||
|
| hose. | |
| Disconnected | Reconnect and check for | |
| selector switch | proper operation. | |
|
|
| |
W ill not run | Loose connections |
| |
at selector switch | R epair connections | ||
| |||
| or control board |
| |
| No power through | C heck continuity of power | |
| power cord | cord and replace if open | |
|
|
| |
| R oom temperature | B in thermistor has unit | |
| shut off C ustomer | ||
| below 55°F (13°C ) | ||
| Instruction | ||
|
| ||
|
|
| |
| Ice touching bin | Normal operation | |
| thermistor | ||
|
| ||
| W ater supply turned | Turn on water supply | |
| off | ||
|
| ||
| Loose or missing | Tighten or replace | |
| reservoir cap | ||
|
| ||
|
|
| |
| W ater slide return tube | R eposition tube | |
| out of reservoir | ||
W ill not make ice |
| ||
|
| ||
Inlet tube out of |
| ||
W ater reservoir is |
| ||
position and missing | R eposition tube | ||
empty | |||
reservoir |
| ||
E vaporator is cold |
| ||
W ater inlet tube frozen |
| ||
with thin or no ice | Thaw and reposition tube | ||
slab | near evaporator |
| |
Defective inlet water | Test and repair or replace | ||
| |||
| valve |
| |
| An ice slab only | Look for interference with | |
| partially released from | ||
| cutter grid and clean the | ||
| evaporator and water | evaporator plate (see | |
| was bridged down into | ||
| procedure on page | ||
| the bin | ||
|
|