Models: GRC65 ML-052085 GRD25 ML-052513, GRD35 ML-052080, GRD45 ML-052081, GRD65 ML-052082, GRD85 ML-052306, GRC35 ML-052083, GRC45 ML-052084, GRC65 ML-052085, GRC85 ML-052307, GRD35F ML-126732, GRD45F ML-126735, GRD65F ML-126738, GRD85F ML-126741, GRC35F ML-126433, GRC45F ML-12 GRC45 ML-052084 GRC35 ML-052083 GRD25 ML-052513 GRD65 ML-052082 GRD45 ML-052081 GRC45F ML-12 GRD35 ML-052080 GRC85 ML-052307 GRD85 ML-052306

1 36
Download 36 pages 20.69 Kb
Page 36
Image 36

ALARMS AND ERROR MESSAGES (GRD and GRC Series)

Pilot Out - If the pilot is out, the control displays the following message:

GRD Models -

FIrE OUt

GRC Models -

PILOT OUT

If no action is taken after 90 seconds, an alarm sounds continuously, the heat demand is disabled and any running cooking cycles are cancelled. The control displays the following message:

GRD Models - Ign LoC

GRC Models - IGNITION LOCKOUT

The fryer must be turned off, then back on before the pilot can be relit and normal fryer functions resumed. See pages 15 and/or 16 for lighting instructions pertaining to your particular model.

Open Probe - If an open probe is detected, the heat demand is disabled and any running cooking cycles are cancelled. All operator buttons are disabled. The control displays the following message:

GRD Models -

Prob

GRC Models -

OPEN PROBE

The alarm sounds continuously until the fault clears or the fryer is turned off, then back on. If the problem persists, call service.

Shorted Probe - If a shorted probe is detected, the heat demand is disabled and any running cooking cycles are cancelled. All operator buttons are disabled. The control displays the following message:

GRD Models - Hi

GRC Models - SHORTED PROBE

The alarm sounds continuously until the fault clears or the fryer is turned off, then back on. If the problem persists, call service.

Hi Temperature - If the temperature is greater than or equal to 415°F (212°C), the heat demand is disabled and any running cooking cycles are cancelled. All operator buttons are disabled. The control displays the following message:

GRD Models - Hi

GRC Models - SHORTED PROBE

The alarm sounds continuously until the fault clears or the fryer is turned off, then back on. Normal fryer operations resumes when temperature drops below 415°F (212°C). If the problem persists, call service.

FORM 31214 Rev. B (07-03)

– 36 –

PRINTED IN U.S.A.

Page 36
Image 36
Vulcan-Hart GRC45F ML-12, GRD85 ML-052306, GRC85 ML-052307 Alarms and Error Messages GRD and GRC Series, Pilot OUT