Vulcan-Hart GRD35 ML-052080 Leveling Fryer, Flue Connections, Electrical Connections

Models: GRC65 ML-052085 GRD25 ML-052513, GRD35 ML-052080, GRD45 ML-052081, GRD65 ML-052082, GRD85 ML-052306, GRC35 ML-052083, GRC45 ML-052084, GRC65 ML-052085, GRC85 ML-052307, GRD35F ML-126732, GRD45F ML-126735, GRD65F ML-126738, GRD85F ML-126741, GRC35F ML-126433, GRC45F ML-12 GRC45 ML-052084 GRC35 ML-052083 GRD25 ML-052513 GRD65 ML-052082 GRD45 ML-052081 GRC45F ML-12 GRD35 ML-052080 GRC85 ML-052307 GRD85 ML-052306

1 36
Download 36 pages 20.69 Kb
Page 13
Image 13

LEVELING FRYER

1.Place a spirit level on top of the fryer after gas connections have been made.

2.Adjust the legs to ensure that the fryer is level front-to-back and side-to side in the final installed position.

FLUE CONNECTIONS

The fryer must be located under a hood with adequate connection to an exhaust duct. The hood must extend 6" (15 cm) beyond fryer sides.

Adequate ventilation must be provided and comply with Vapor Removal from Cooking Equipment, ANSI-NFPA Standard #96 (latest edition), available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

Clearance above the fryer should be adequate for combustion byproducts to be removed efficiently. An 18" (46 cm) minimum clearance should be maintained between the flue vent and the filters of the hood venting system. Never make flue connections directly to the fryer.

Do not obstruct the flow of the flue gases from the appliance. Proper air balance should be maintained in the room.

ELECTRICAL CONNECTIONS

WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL CODES.

WARNING: APPLIANCES EQUIPPED WITH ELECTRICAL SUPPLY CORD(S) ARE PROVIDED WITH A THREE-PRONG GROUNDING PLUG, WHICH MUST BE CONNECTED TO A PROPERLY GROUNDED RECEPTACLE. IF THE RECEPTACLE IS NOT THE PROPER GROUNDING TYPE, CONTACT AN ELECTRICIAN. DO NOT REMOVE THE GROUNDING PRONG FROM THE PLUG.

Fryers are equipped with a 120 V, 60 Hz, 1-phase cord and plug.

Do not connect fryer to electrical supply until after gas connections have been made.

– 13 –

Page 13
Image 13
Vulcan-Hart GRD35 ML-052080, GRD85 ML-052306, GRC85 ML-052307 Leveling Fryer, Flue Connections, Electrical Connections