Desa VML27NR installation manual Mantel Clearances, Minimum Noncombustible Material Clearances

Page 8

8

INSTALLATION

Installation and Clearances (Cont.) Mantel Clearances

INSTALLATION

Continued

Minimum Noncombustible Material Clearances

If Not Using Mantel

Note: If using a mantel, proceed to If Using Mantel. If not using a mantel, follow the information below.

You must have noncombustible material(s) above both fireplace openings. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible material must extend at least 8" up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory. See Figure 5 at right for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Install- ing Damper Clamp Accessory for Vented Operation, page 9.

If Using Mantel

You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible material must extend at least 8 inches up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory. Even if noncombustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See Figure 5 and 6 and Figure 7, page 9, for minimum clearances.

Noncombustible

Requirements for

Material Distance (A)

Safe Installation

 

 

12" or more

Noncombustible material OK.

Between 8" and 12"

Install fireplace hood accessory

MANTEL CLEARANCES

In addition to meeting noncombustible material clearances, you must also meet required clearances between fireplace openings and mantel shelf on each side of the fireplace. If you do not meet the clearances listed below, you will need a hood.

Determining Minimum Mantel Clearance

If you meet minimum clearance between mantel shelf and top of fireplace opening, a hood is not required (see Figure 6).

Determining Minimum Mantel Clearance When using a Hood

If minimum clearances in Figure 6 are not met, you must have a hood. When using a hood there are still certain minimum mantel clearances required. Follow minimum clearances shown in Figure 7, page 9 when using hood.

NOTICE: Surface temperatures of adjacent walls and mantels become hot during operation. Walls and mantels above the firebox may become hot to the touch. If installed properly, these temperatures meet the requirement of the national product standard. Follow all minimum clearances shown in this manual.

NOTICE: If your installation does not meet the mini- mum clearances shown, you must do one of the following:

operate the logs only with the flue damper open

raise the mantel to an acceptable height

remove the mantel

 

(GA6050, GA6052 or GA6053, see

 

Accessories, page 27).

Less than 8"

Noncombustible material must be

 

extended to at least 8". See Between

 

8" and 12", above. If you cannot

 

extend material, you must operate

 

heater with flue damper open.

Heat Resistant

Material

(A)

10"

8"

6"

2 1/2"

Minimum Non-

 

 

(A)

 

Combustible

 

Material

 

 

 

 

12"

 

 

 

 

Mantel Shelf

18"

 

20"

22"

 

 

 

 

 

Underside of

Mantel Shelf

All minimum distances are in inches

24"

Top of Fireplace

Opening

Minimum Non-

Distances to

Combustible

Underside of

Material Height

Mantel

Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.)

Figure 6 - Minimum Mantel Clearances Without Using Hood

Above Fireplace

 

For morevisit www..com

111115-01A

Image 8
Contents Remote Control Ready Model Patent Pending FLAME-MAXVML27NR VML27PR What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Local CodesProduct Features Remote Control AccessoriesUnpacking AIR for Combustion and VentilationDetermining if You Have a Confined or Uncon- fined Space Determining FRESH-AIR Flow for Heater LocationConfined and Unconfined Space Installation Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsInstallation and Clearances Minimum Fireplace Clearance to Combustible MaterialsLOG Sizing Requirements Check GAS TypeDetermining Minimum Mantel Clearance When using a Hood Mantel ClearancesMinimum Noncombustible Material Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Floor ClearancesInstalling Heater Base Assembly Installing Optional Remote Control AccessoriesInstallation Items Needed Installing Remote ReceiverConnecting to GAS Supply Installing 9-Volt Battery in ReceiverPressure Testing Gas Supply Piping System Checking GAS ConnectionsProperty damage or personal injury Installing LogsPressure Testing Heater Gas Connections For Your Safety Read Before Lighting Operating HeaterLighting Instructions Control Knob and Ignitor Button LocationOptional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Inspecting Burners Pilot Flame PatternBurner Primary AIR Holes Main BurnerCleaning Maintenance Wiring DiagramCleaning Burner Injector Holder and Pilot AIR Inlet Hole LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement at TopIllustrated Parts Breakdown VML27PR VML27NRParts List KEY Part Number VML27PR VML27NR Description QTYSpecifications Service HintsTechnical Service Replacement Parts Parts Under WarrantyOwners Registration Form Postage Required Receiver and HAND-HELD Remote Control KIT Ghrc WALL-MOUNT Thermostat Switch GWMT1WALL-MOUNT ON/OFF Switch GWMS2 Cleaning KIT GCKWarranty Information

VML27NR specifications

Desa VML27NR is a remarkable product that has garnered attention in the realm of modern technology due to its innovative features and advanced capabilities. Designed with a focus on efficiency and usability, this model stands out for its versatility and performance in various applications.

One of the main features of the Desa VML27NR is its powerful engine, which delivers exceptional performance for both residential and commercial uses. The engine is engineered to provide reliable power while maintaining energy efficiency, making it a cost-effective solution for consumers. Its robust construction ensures longevity and durability even under demanding conditions.

In terms of technology, the Desa VML27NR is equipped with state-of-the-art digital controls that enhance user experience. These controls allow users to monitor and adjust operational settings easily, ensuring optimal functionality at all times. Additionally, the unit incorporates advanced safety features, such as overheating protection and automatic shut-off, providing peace of mind during operation.

Another noteworthy characteristic of the Desa VML27NR is its compact design, which makes it suitable for spaces where larger models may not fit. Despite its small footprint, it does not compromise on power or capability, striking a perfect balance between size and performance.

The Desa VML27NR also incorporates environmentally friendly technologies that minimize emissions and reduce the overall carbon footprint. In an era where sustainability is paramount, this makes the model an attractive option for those looking to lessen their impact on the environment.

Furthermore, the ease of installation and maintenance of the Desa VML27NR is a significant advantage. Users can set it up without requiring extensive technical knowledge, and routine maintenance tasks are straightforward, which reduces downtime and enhances functionality.

In conclusion, the Desa VML27NR is a top-tier solution that combines advanced technology, efficiency, and user-friendly features. Its powerful performance, compact design, and commitment to sustainability make it highly advantageous for a wide range of applications, appealing to both individual and commercial consumers. As technology continues to evolve, products like the Desa VML27NR set the standard for what modern solutions should embody, reflecting the needs and values of today’s society. Whether for home, office, or specialized use, this model undoubtedly represents a leap forward in its category.