Desa VML27NR installation manual Observed Problem Possible Cause Remedy

Page 20

20

TROUBLESHOOTING

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Burner does not light after ODS/pilot is lit

1.

Burner orifice clogged

 

2.

Inlet gas pressure is too low

 

3.

Thermopile leads disconnected or im-

 

 

properly connected

 

4.

Burners will not come on in remote

 

 

position

1.Clean burner (see Cleaning and Mainte- nance, page 18) or replace burner orifice

2.Contact local natural or propane/LP gas company

3.Reconnect leads (see Wiring Diagram, page 18)

4.Replace battery in transmitter and re- ceiver

Delayed ignition burner

1.

Manifold pressure is too low

1.

Contact local natural or propane/LP gas

 

 

 

 

company

 

2.

Burner orifice clogged

2.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 18) or replace burner orifice

 

 

 

 

 

Burner backfiring during combustion

1.

Burner orifice is clogged or damaged

1.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 18) or replace burner orifice

 

2.

Damaged burner

2.

Replace damaged burner

 

3.

Gas regulator defective

3.

Replace gas control

 

 

 

 

 

Slight smoke or odor during initial operation

1.

Not enough air

1.

Check burner for dirt and debris. If

 

 

 

 

found, clean burner (see Cleaning and

 

 

 

 

Maintenance, page 18)

 

2.

Gas regulator defective

2.

Replace gas control

 

3.

Residues from manufacturing processes

3.

Problem will stop after a few hours of

 

 

and logs curing

 

operation

 

 

 

 

 

Moisture/condensation noticed on windows

1.

Not enough combustion/ventilation air

1.

Refer to Air for Combustion and Venti-

 

 

 

 

lation requirements (page 4)

 

 

 

 

 

Heater produces a whistling noise when

1.

Turning control knob to HI position

1.

Turn control knob to LO position and

burner is lit

 

when burner is cold

 

let warm up for a minute

 

2.

Air in gas line

2.

Operate burner until air is removed from

 

 

 

 

line. Have gas line checked by local

 

 

 

 

natural or propane/LP gas company

 

3.

Air passageways on heater blocked

3.

Observe minimum installation clear-

 

 

 

 

ances (see pages 7 through 9)

 

4.

Dirty or partially clogged burner orifice

4.

Clean burner (see Cleaning and Mainte-

 

 

 

 

nance, page 18) or replace burner orifice

White powder residue forming within burner box or on adjacent walls or furniture

1.When heated, vapors from furniture pol- ish, wax, carpet cleaners, etc. may turn into white powder residue

1.Turn heater off when using furniture polish, wax, carpet cleaners, or similar products

Remote does not function

1. Battery is not installed. Battery power

 

is low

1.Replace 9-volt batteries in receiver and remote control

For morevisit www..com

111115-01A

Image 20
Contents Remote Control Ready Model Patent Pending FLAME-MAXVML27NR VML27PR What to do if YOU Smell GASTable of Contents Safety InformationProduct Identification Local CodesProduct Features Remote Control AccessoriesUnpacking AIR for Combustion and VentilationDetermining if You Have a Confined or Uncon- fined Space Determining FRESH-AIR Flow for Heater LocationConfined and Unconfined Space Installation Ventilation AIRVentilation Air From Inside Building Ventilation Air From OutdoorsInstallation and Clearances Minimum Fireplace Clearance to Combustible MaterialsLOG Sizing Requirements Check GAS TypeDetermining Minimum Mantel Clearance When using a Hood Mantel ClearancesMinimum Noncombustible Material Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Floor ClearancesInstalling Heater Base Assembly Installing Optional Remote Control AccessoriesInstallation Items Needed Installing Remote ReceiverConnecting to GAS Supply Installing 9-Volt Battery in ReceiverPressure Testing Gas Supply Piping System Checking GAS ConnectionsProperty damage or personal injury Installing LogsPressure Testing Heater Gas Connections For Your Safety Read Before Lighting Operating HeaterLighting Instructions Control Knob and Ignitor Button LocationOptional Remote Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Inspecting Burners Pilot Flame Pattern Burner Primary AIR Holes Main BurnerCleaning Maintenance Wiring DiagramCleaning Burner Injector Holder and Pilot AIR Inlet Hole LogsTroubleshooting Observed Problem Possible CauseObserved Problem Possible Cause Remedy Gas leak. See Warning statement at TopIllustrated Parts Breakdown VML27PR VML27NRParts List KEY Part Number VML27PR VML27NR Description QTYSpecifications Service HintsTechnical Service Replacement Parts Parts Under WarrantyOwners Registration Form Postage Required Receiver and HAND-HELD Remote Control KIT Ghrc WALL-MOUNT Thermostat Switch GWMT1WALL-MOUNT ON/OFF Switch GWMS2 Cleaning KIT GCKWarranty Information