• control cover kit (provided with heater)
• approved flexible gas hose (if allowed by local codes)
• sealant (resistant to propane/LP gas, not provided)
1.Apply pipe joint sealant lightly to male threads of gas fitting (not provided). Connect approved flexible gas hose to inlet side of gas control (see Figure 10). IMPORTANT: Hold gas fitting with wrench when connecting flexible gas hose.
2.Position heater assembly in fireplace.
3.Connect to gas supply. See Connecting to Gas Supply.
Flexible Gas Hose
(if allowed by local codes)
Fitting
Figure 10 - Attaching Flexible Gas Hose
to Regulator
connecting to gas supply
WARNING: This appliance requires a 1/2" NPT (National Pipe Thread) inlet connection to the shutoff valve.
WARNING:Aqualifiedservice personmustconnectheatertogas supply. Follow all local codes.
CAUTION: Never connect propane/LP fireplace directly to the propane/LP supply. This heater requires an external regu- lator (not supplied). Install the external regulator between the heater and propane/LP supply.
WARNING: Never connect natural gas fireplace to private
Installation Items Needed
Before installing heater, make sure you have the items listed below.
•external regulator (for propane/LP units only, supplied by installer)
•piping (check local codes)
•sealant (resistant to propane/LP gas)
•equipment shutoff valve *
•test gauge connection *
•sediment trap
•tee joint
•pipe wrench
•approved flexible gas line with gas connector (if allowed by local codes)
*A CSA
For propane/LP units, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pres- sure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure 11. Pointing the vent down protects it from freezing rain or sleet.
CAUTION:Useonlynew,black
Propane/LP
Supply Tank
External
Regulator
Vent
Pointing
Down
Figure 11 - External Regulator With Vent
Pointing Down