Desa VF-18P-MHd, VF-18N-MHd installation manual Functions, Remote Control

Page 16

Operating Heater

Continued

6.

Press the buttons

and

at the same

 

time. A short acoustic signal confirms the

 

start sequence has begun.

 

 

Further short acoustic signals (0.2 sec., 1 Hz)

 

indicate the ignition process until it is com-

 

pleted and main gas flows. If pilot is already

 

lit, motor will turn on (max. flame height)

 

while buttons are pressed down. If pilot does

 

not light, see Troubleshooting, page 21.

7.

Press

to turn on main burner and in-

 

crease flame height. Press

to decrease

 

flame height and shut off main burner.

8.Short tapping of either button allows incre- mental change in flame height.

9.Press OFF button to switch off main gas and pilot gas.

Functions of

REMOTE CONTROL

Battery

• After the charged battery has been correctly installed, the remote hand set is ready for operations.

• Remove the battery if the remote handset will not be used more than one year.

Changing The Code

The control is radio frequency operated. A code (chosen from among 4,000 available codes) is preset for all valves, but can be changed if re- quired (15 additional codes available). Change DIP switch position. (The DIP switch is located inside the hand held control at the top of the battery compartment.) Then press the receiver's reset button on the bottom of the receiver module until you hear a second (longer) signal. When pressing the button on the remote handset in the following 20 sec., the receiver learns the new code.

SET

STAND

OFFBY

Figure 17 - Control Panel for Hand-Held Remote

Shut-off Procedure

To save battery power; press to turn main gas to pilot gas. Press OFF button to shut off the device including pilot flame. The device can be shut off with ON/OFF switch, thus disabling the remote hand set.

Setting The Display ( °C/24h and °F /12h)

Press and hold OFF and until display changes from °F (and 12 hour clock) to °C (and 24 hour clock) or vice versa.

Setting The Time

 

 

• After connecting the battery or by simulta-

neously pressing

and

the display will

start to flash. You are in the set mode.

• From SET mode press

to set the hour and

to set the minute.

 

Wait or press OFF to return to the manual mode.

Battery Replacement

Remote handset battery needs to be changed when LED is dim. Battery life expectancy is 2 to 3 years. Replacement is recommended at the beginning of heating season. Battery needs to be changed when acoustic error message appears during ignition (see Identifying Error Signals from Receiver on page 24).

Changing Mode of Operation

• Press the SET button quickly to change the mode of operation in the following order:

MAN,

 

 

TEMP, TEMP, TIMER.

 

 

• Manual

flame height adjustment (MAN ap-

pears on display): Press to turn on the fire

(main burner) or to increase flame height.

Press

 

to decrease flame or to go down

to pilot only. The receiver acknowledges the transmission with an acoustic signal.

The day time temperature mode ( TEMP ap- pears on display): The sensor in the transmitter measures room temperature. The controller compares the room temperature with set tem- perature and sends a signal to the receiver to turn the gas valve motor up or down, to adjust the flame height accordingly.

The nighttime setback temperature ( TEMP appears on display): The sensor in the transmitter measures the temperature and adjusts it according to the nighttime setback temperature. There is a bigger temperature differential during this cycle.

16

www.desatech.com

116986-01B

Image 16
Contents What to do if YOU Smell GAS Models VF-18N-MHD, VF-18P-MHD, VF-24N-MHD VF-24P-MHDTable of Contents Safety Information Product Identification Product IdentificationProduct Features Local CodesUnpacking Air For Combustion VentilationConfined and Unconfined Space Determining fresh-air flow for heater locationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Check GAS TypeInstallation and clearances for vent-free operation Installation Installing Heater Assembly Determining Minimum Mantel Clearance When using a HoodMantel Clearances Floor ClearancesConnecting to gas supply Installation Items NeededNatural Gas Checking gas connectionsPropane/LP Gas Adding Embers, Lava rock and Decorative logs Pressure Testing Heater Gas ConnectionsTest Pressures Equal To or Less Than Psig 3.5 kPa For your safety Read before lighting Operating HeaterRemote Control FunctionsProcedure Manual LightingInspecting Burners To turn gas off To appliancePilot Flame Pattern Lighting with Piezo IgnitorBurner Flame Pattern Cleaning MaintenanceBurner Injector Holder Air Inlet Hole Injector Holder on Front Burner Tube Troubleshooting Observed Problem Possible Cause RemedySee Cleaning and Mainte Bad module Replace module Gas leak. See WarningWiring Diagram Identifying error signals from receiverReplacement Parts Service HintsTechnical Service AccessoriesIllustrated Parts Breakdown Models VF-18N-MHD, VF-18P-MHD, VF-24N-MHD and VF-24P-MHDParts List Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS LOG Heaters