Desa RH10PT installation manual Inspecting Heater

Page 12

OPERATING HEATER

Continued

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2.Turn off all electric power to the appliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise to the PILOT position.

THERMOSTAT CONTROL

OPERATION

The thermostatic control used on these models differs from standard thermostats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room temperature. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any heat level between 1 and 5. Selecting the 5 setting will cause the burner to remain fully on without modulating down in most cases.

Note: The thermostat sensing bulb measures the temperature of air near the heater cabinet. This may not always agree with room tem- perature (depending on housing construction, installation location, room size, open air tem- peratures, etc.). Frequent use of your heater will let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 8, page 7).

2.Follow steps 1 through 7 under Lighting Instructions, page 11.

3.With control knob pressed in, strike match. Hold match to pilot until pilot lights.

4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 9, under Lighting Instructions, page 11.

5.Replace front panel.

INSPECTING HEATER

Check pilot flame pattern and burner flame pat- tern often.

PILOT FLAME PATTERN

Figure 18 shows a correct pilot flame pattern. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 19

turn heater off (see To Turn Off Gas to Appliance)

see Troubleshooting, page 14

Thermocouple

Pilot Burner

 

Figure 18 - Correct Pilot Flame Pattern

Thermocouple

Pilot Burner

 

Figure 19 - Incorrect Pilot Flame Pattern

BURNER FLAME PATTERN

Figure 20, page 13, shows a correct burner flame pat-

tern. Figure 21, page 13, shows an incorrect burner

flame pattern. The incorrect burner flame pattern

shows yellow tipping of the flame. It also shows the

flame higher than 1/2 the glass panel height.

WARNING: If yellow tipping

occurs, your heater could pro-

duce increased levels of carbon

monoxide.

 

 

 

NOTICE: Do not mistake orange

flames with yellow tipping. Dirt

or other fine particles enter the

heater and burn causing brief

patches of orange flame.

 

If burner flame pattern is incorrect, as shown in

Figure 21, page 13

 

turn heater off (see To Turn Off Gas to Appliance)

see Troubleshooting, page 14

12

www.desatech.com

110373-01E

Image 12
Contents What to do if YOU Smell GAS Table of Contents Safety Information Do not USE this Heater insideLocal Codes UnpackingProduct Features InstallationProduct Identification PROPANE/LP SupplyInstalling Heater to Wall Thermostat Sensing BulbInstalling Bottom Mounting Screw Removing Front Panel Of HeaterPlacing Heater On Mounting Screws Connecting to Portable Cylinder GAS Supply Connecting to PermanentGAS Supply Remove 90 gas fitting from hardware bagInstallation Items From your dealer. See Accessories,If installing to a fixed fuel piping system, Dealer. See Accessories,Checking GAS Connections for Permanent GAS Supply Test Pressures In Excess Of 1/2 Psig 3.5 kPaTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa For Your Safety Read Before Lighting Operating HeaterLighting Instructions Ignitor Button Control KnobInspecting Heater Cleaning Maintenance CabinetTroubleshooting Observed Problem Possible Cause RemedyDelayed ignition of burner Manifold pressure is too low Burner orifice is clogged Clean burner see CleaningWhen burner is lit Est position when burner is Or shut off Qualified service personGas leak. See Warning Statement aboveSpecifications Service HintsTechnical Service Service Publications AccessoriesIllustrated Parts Breakdown Parts List NJF-8CWarranty Information Keep this Warranty

RH10PT specifications

Desa RH10PT is a cutting-edge development that showcases the latest advancements in sustainable living and smart technology integration. Situated in an eco-friendly environment, this residential project boasts an impressive array of features designed to enhance the quality of life for its residents while minimizing environmental impact.

One of the main characteristics of Desa RH10PT is its commitment to sustainability. The development incorporates green building practices, utilizing eco-friendly materials and adhering to energy-efficient standards. Solar panels are installed on rooftops, providing residents with renewable energy that reduces electricity costs and carbon footprints. Rainwater harvesting systems are also integrated, allowing for the collection and reuse of water for irrigation and other non-potable uses.

In addition to its sustainability initiatives, Desa RH10PT is designed with smart technology in mind. The residential units are equipped with advanced home automation systems that enable residents to control lighting, heating, and security features remotely via smartphones or tablets. This technology not only enhances convenience but also improves energy management by allowing occupants to monitor and adjust their energy consumption in real time.

Safety is another paramount aspect of Desa RH10PT. The community is secured with state-of-the-art surveillance systems and gated entry points, ensuring a safe living environment for families. Additionally, the design of the neighborhood encourages a sense of community while providing ample green spaces, parks, and recreational facilities. This thoughtful layout promotes outdoor activities and fosters social interactions among residents.

Furthermore, Desa RH10PT emphasizes connectivity and accessibility. The development is strategically located near major transportation hubs, educational institutions, and healthcare facilities, making it an attractive option for families and professionals alike. The integration of walking and biking paths throughout the community encourages healthy lifestyles and reduces reliance on vehicles.

In conclusion, Desa RH10PT represents a modern approach to housing that harmonizes sustainability, technology, and community living. With its innovative features, eco-friendly practices, and smart home technologies, this development is poised to set a benchmark for future residential projects, ultimately shaping the way we think about urban living. Residents are afforded the opportunity to embrace a lifestyle that is not only comfortable but also responsible and forward-thinking, positioning Desa RH10PT as a model for sustainable, modern living in today's world.