Desa RH10PT installation manual Local Codes, Unpacking

Page 4

SAFETY INFORMATION

Continued

1.Install and use heater with care. Follow all local ordinances and codes. In the absence of local ordinances and codes, refer to the Standard for Storage and Handling of Lique- fied Petroleum Gas, ANSI/NFPA 58 and the Natural Gas Installation Code, CAN/CGA B149.2. This instructs on the safe storage and handling of propane/LP gases.

2.This appliance is only for use with the type of gas indicated on the rating plate. This ap- pliance is not convertible for use with other gases.

3.This heater may be used in a recreational enclosure or temporary construction work enclosure with a remote refillable propane/LP cylinder ONLY when the cylinder is located outdoors and the heater is used with the hose kit #LPA3090 (included with this heater). NEVER bring a refillable propane/LP cylinder indoors. A fire or explosion can occur causing property damage, serious injury or death.

4.Use only the hose and factory preset regulator provided with the heater. Use only replacement pressure regulators and hose assemblies speci- fied in this manual. See Accessories, page 17.

5.Inspect the hose before each use of the heater. If it is evident there is excessive abrasion or wear or the hose is cut, it must be replaced prior to the heater being put into operation. Use replacement hose assembly kit #LPA3090 (see Accessories, page 17).

6.Use only propane gas set up for vapor with- drawal.

7.This heater shall not be installed in a bedroom or bathroom.

8.This heater needs fresh, outside air ventilation to run properly. This heater has an Oxygen Depletion Sensing (ODS) safety shutoff sys- tem. The ODS shuts down the heater if not enough fresh air is available. You must provide a minimum 10 square inches of ventilation air for adequate combustion.

9.If heater shuts off, do not relight until you provide fresh, outside air. If heater keeps shutting off, have it serviced.

10.Keep all air openings in front and bottom of heater clear and free of debris. This will insure enough air for proper combustion.

11.Do not use heater if any part has been under water. Immediately call a qualified service technician to inspect the room heater and to replace any part of the control system and any gas control which has been under water.

12.Turn off and let cool before servicing. Only a qualified service person should service and repair heater.

13.Operating heater above elevations of 4,500 feet could cause pilot outage.

14.Turn off propane/LP supply when not in use.

15.Check heater for damage before each use. Do not use a damaged heater.

16.Do not alter heater. Keep heater in its original state.

17.Do not use heater if altered.

18.This heater can only be used in a recreational or commercial enclosure with a window or roof vent. This heater is not for outdoor use.

19.Before using the heater provide adequate ventilation. An area of 10 square inches of opening of a window or roof vent is needed for adequate combustion and ventilation air.

LOCAL CODES

Install and use heater with care. Follow all lo- cal codes. In the absence of local codes, use the latest edition of National Fuel Gas Code, ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

UNPACKING

1.Remove heater from carton.

2.Remove all protective packaging applied to heater for shipment.

3.Check heater for any shipping damage. If heater is damaged, promptly return to dealer where you bought heater.

4

www.desatech.com

110373-01E

Image 4
Contents What to do if YOU Smell GAS Table of Contents Safety Information Do not USE this Heater insideLocal Codes UnpackingProduct Features InstallationProduct Identification PROPANE/LP SupplyInstalling Heater to Wall Thermostat Sensing BulbRemoving Front Panel Of Heater Installing Bottom Mounting ScrewPlacing Heater On Mounting Screws Connecting to Portable Cylinder GAS Supply Connecting to PermanentGAS Supply Remove 90 gas fitting from hardware bagInstallation Items From your dealer. See Accessories,If installing to a fixed fuel piping system, Dealer. See Accessories,Test Pressures In Excess Of 1/2 Psig 3.5 kPa Checking GAS Connections for Permanent GAS SupplyTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa For Your Safety Read Before Lighting Operating HeaterLighting Instructions Ignitor Button Control KnobInspecting Heater Cleaning Maintenance CabinetTroubleshooting Observed Problem Possible Cause RemedyDelayed ignition of burner Manifold pressure is too low Burner orifice is clogged Clean burner see CleaningWhen burner is lit Est position when burner is Or shut off Qualified service personGas leak. See Warning Statement aboveSpecifications Service HintsTechnical Service Service Publications AccessoriesIllustrated Parts Breakdown Parts List NJF-8CWarranty Information Keep this Warranty

RH10PT specifications

Desa RH10PT is a cutting-edge development that showcases the latest advancements in sustainable living and smart technology integration. Situated in an eco-friendly environment, this residential project boasts an impressive array of features designed to enhance the quality of life for its residents while minimizing environmental impact.

One of the main characteristics of Desa RH10PT is its commitment to sustainability. The development incorporates green building practices, utilizing eco-friendly materials and adhering to energy-efficient standards. Solar panels are installed on rooftops, providing residents with renewable energy that reduces electricity costs and carbon footprints. Rainwater harvesting systems are also integrated, allowing for the collection and reuse of water for irrigation and other non-potable uses.

In addition to its sustainability initiatives, Desa RH10PT is designed with smart technology in mind. The residential units are equipped with advanced home automation systems that enable residents to control lighting, heating, and security features remotely via smartphones or tablets. This technology not only enhances convenience but also improves energy management by allowing occupants to monitor and adjust their energy consumption in real time.

Safety is another paramount aspect of Desa RH10PT. The community is secured with state-of-the-art surveillance systems and gated entry points, ensuring a safe living environment for families. Additionally, the design of the neighborhood encourages a sense of community while providing ample green spaces, parks, and recreational facilities. This thoughtful layout promotes outdoor activities and fosters social interactions among residents.

Furthermore, Desa RH10PT emphasizes connectivity and accessibility. The development is strategically located near major transportation hubs, educational institutions, and healthcare facilities, making it an attractive option for families and professionals alike. The integration of walking and biking paths throughout the community encourages healthy lifestyles and reduces reliance on vehicles.

In conclusion, Desa RH10PT represents a modern approach to housing that harmonizes sustainability, technology, and community living. With its innovative features, eco-friendly practices, and smart home technologies, this development is poised to set a benchmark for future residential projects, ultimately shaping the way we think about urban living. Residents are afforded the opportunity to embrace a lifestyle that is not only comfortable but also responsible and forward-thinking, positioning Desa RH10PT as a model for sustainable, modern living in today's world.