Desa CCL3930NTB installation manual What to do if YOU Smell GAS, 18, 24, and 30 Variable

Page 1

UNVENTED (VENT-FREE)

GAS LOG HEATER

OWNER’S OPERATION AND

INSTALLATION MANUAL

For

visit

.

.com

18", 24", and 30" Variable

 

 

18", 24", and 30"

Manually-Controlled Models

 

 

Thermostatically-Controlled Models

CRL2718P/N

 

 

CGD3924PT/NT

CRL3124P/N

 

 

CGD3018PT/NT

CCL3018PA/NA

 

 

CCL3018PTA/NTA

CCL3924PA/NA

 

 

CCL3924PTA/NTA

 

 

 

CCL3930PTB/NTB

Patent Pending

(Smoky Mountain Oak Model Shown)

BILTMORE SPLIT OAK, SEASONAL OAK

AND SMOKY MOUNTAIN OAK LOGS

Variable Manually-Controlled Models Also

Design-Certified As Vented Decorative Appliances

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas

WARNING: Improper installation, adjust- ment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installa- tion and operational procedures. For as- sistance or additional information con- sult a qualified installer, service agency, or the gas supplier.

WARNING: This appliance is for installa- tion only in a solid-fuel burning masonry or UL127 factory-built fireplace, or in an approved ventless firebox. It is design- certified for these installations in accor- dance with ANSI Z21.11.2. Exception: Do not install this appliance in a factory- built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs.

WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation section on page 4 of this manual.

This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Save thisfor.

Image 1
Contents 18, 24, and 30 Variable What to do if YOU Smell GASCRL2718P/N CRL3124P/NSafety Information Table of ContentsProduct Identification Local Codes Product Features AIR for Combustion and VentilationUnpacking Confined and Unconfined Space Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Uncon- fined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationMinimum Noncombustible Material Clearances If Using MantelMantel Clearances Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Attaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping systemPressure Testing Heater Gas Connections Installing LogsInstalling Back Log #1 Installing Middle Log #2 CCL3930PTB/NTB Shown Single Burner Seasonal Oak Models CRL2718P/N, CRL2718P/N Installing Crossover Log #6 CCL3930PTB/NTB ShownLighting Instructions Operating HeaterTo Turn OFF GAS Variable Control OperationTo Appliance Shutting Off HeaterInstructions Manual Lighting ProcedureTo Turn OFF GAS To Appliance Inspecting BurnersThermostat Control Operation Pilot Flame PatternCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceBurner Primary AIR Holes Main BurnerObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement For Masonry and Factory-built Metal Fireplace Optional Positioning of Thermostat Sensing BulbAccessories Replacement PartsService Hints Technical ServiceDual Burner Smoky Mountain OAK Models SpecificationsDual Burner Biltmore Split OAK Models Single Burner Seasonal OAK ModelsIllustrated Parts Breakdown Variable MANUALLY-CONTROLLED Biltmore Split OAK Models Parts ListModels CGD3018PT, CGD3018NT, CGD3924PT and CGD3924NT THERMOSTATICALLY-CONTROLLED Smoky Mountain OAK Models Models CCL3018PTA and CCL3018NTA KEY Part Number CCL3018PTA CCL3018NTA Description QTY THERMOSTATICALLY-CONTROLLED Biltmore Split OAK ModelsModels CCL3924PTA, CCL3924NTA, CCL3930PTB and CCL3930NTB Parts List CRL3124P and CRL3124N Variable Manually Controlled Seasonal OAKDescription QTY Variable MANUALLY-CONTROLLED Seasonal OAK ModelsParts Central Owners Registration Form Postage Required 111160-01B Keep this Warranty Warranty Information