Desa CCL3018NTA, CCL3018PTA, CCL3924NA Minimum Noncombustible Material Clearances, If Using Mantel

Page 8

8

INSTALLATION

Installation and Clearances for Vent-Free Operation (Cont.)

INSTALLATION

Continued

Minimum Clearances For Side Combustible Mate- rial, Side Wall, and Ceiling

A.Clearances from the side of the fireplace cabinet to any com- bustible material and wall should follow diagram in Figure 5.

Example: The face of a mantel, bookshelf, etc. is made of combustible material and protrudes 3 1/2" from the wall. This combustible material must be 4" from the side of the fireplace opening (see Figure 5).

Note: When installing your gas logs into a manufactured fire- box, follow firebox manufacturer’s instructions for minimum clearances to combustible materials.

B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.

Example

*

*Minimum 16 inches from Side Wall

Figure 5 - Minimum Clearance for Combustible to Wall

NOTICE: Manual control heaters may be used as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, noncombustible material above fire- place opening is not needed. Go to Installing Damper Clamp Accessory for Vented Operation, page 10.

If Using Mantel

You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible material must extend at least 8" up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). Even if noncombustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See Figure 6 and Figures 7 and 8 on page 9 for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Install- ing Damper Clamp Accessory for Vented Operation, page 10.

Noncombustible

Requirements for

Material Distance (A)

Safe Installation

 

 

12" or more

Noncombustible material okay.

Between 8" and 12"

24" or 30" Models: Install

 

fireplace hood accessory

 

(GA6050, GA6052, or

 

GA6053 see Accessories,

 

page 28).

 

18" Model: Noncombustible

 

material okay.

Less than 8"

Noncombustible material

 

must be extended to at least

 

8". See Between 8" and 12",

 

above. If you cannot extend

 

material, you must operate

 

heater with flue damper open.

 

 

Minimum Noncombustible Material Clearances

If Not Using Mantel

Note: If using a mantel, proceed to If Using Mantel. If not using a mantel, follow the information below.

You must have noncombustible material(s) above the fireplace opening. Noncombustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have noncombustible material behind it. Noncombustible material must extend at least 8" up (for all models). If noncombustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). See Figure 6 for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Install- ing Damper Clamp Accessory for Vented Operation, page 10.

Heat Resistant

Material

(A)

Figure 6 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace

For..com

111160-01B

Image 8
Contents What to do if YOU Smell GAS 18, 24, and 30 VariableCRL2718P/N CRL3124P/NTable of Contents Safety InformationProduct Identification Unpacking Product Features AIR for Combustion and VentilationLocal Codes Determining if You Have a Confined or Uncon- fined Space Determining FRESH-AIR Flow for Heater Location Confined and Unconfined Space Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation Check GAS TypeIf Using Mantel Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance When Using a Hood Mantel ClearancesFloor Clearances Determining Minimum Mantel ClearanceInstallation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Connecting to GAS Supply Attaching Flexible Gas Hose to Heater Gas RegulatorPressure Testing Gas Supply Piping system Checking GAS ConnectionsInstalling Logs Pressure Testing Heater Gas ConnectionsInstalling Back Log #1 Installing Middle Log #2 CCL3930PTB/NTB Shown Installing Crossover Log #6 CCL3930PTB/NTB Shown Single Burner Seasonal Oak Models CRL2718P/N, CRL2718P/NOperating Heater Lighting InstructionsVariable Control Operation To Turn OFF GASTo Appliance Shutting Off HeaterManual Lighting Procedure InstructionsInspecting Burners To Turn OFF GAS To ApplianceThermostat Control Operation Pilot Flame PatternCleaning Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleBurner Primary AIR Holes Main BurnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement Optional Positioning of Thermostat Sensing Bulb For Masonry and Factory-built Metal FireplaceReplacement Parts AccessoriesService Hints Technical ServiceSpecifications Dual Burner Smoky Mountain OAK ModelsDual Burner Biltmore Split OAK Models Single Burner Seasonal OAK ModelsIllustrated Parts Breakdown Parts List Variable MANUALLY-CONTROLLED Biltmore Split OAK ModelsModels CGD3018PT, CGD3018NT, CGD3924PT and CGD3924NT THERMOSTATICALLY-CONTROLLED Smoky Mountain OAK Models Models CCL3018PTA and CCL3018NTA THERMOSTATICALLY-CONTROLLED Biltmore Split OAK Models KEY Part Number CCL3018PTA CCL3018NTA Description QTYModels CCL3924PTA, CCL3924NTA, CCL3930PTB and CCL3930NTB Parts List Variable Manually Controlled Seasonal OAK CRL3124P and CRL3124NVariable MANUALLY-CONTROLLED Seasonal OAK Models Description QTYParts Central Owners Registration Form Postage Required 111160-01B Warranty Information Keep this Warranty