OPERATING HEATER (Manually Controlled Models)

Lighting Instructions (Cont.)

Variable Control Operations

To Turn Gas Off to Appliance

OPERATING HEATER

Continued

Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the HI heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.

WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information in column 2, page 17.

2.Make sure equipment shutoff valve is fully open.

3. Press in and turn control knob clockwise Clockwise to the

OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol- low “B” in the safety information, column 2 on page 17. If you don’t smell gas, go to the next step.

5.Slightly depress and turn control knob counterclockwise

C-clockwiseto the PILOT position. Press in control knob for five

(5) seconds (see Figure 35).

Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control knob may need to be pressed in for 30 seconds or more. This will al- low air to bleed from the gas system.

HI

PILOT

 

OFF

LO

 

Ignitor Button

Control Knob

Figure 35 - Control Knob and Ignitor Button Location

6.With control knob pressed in, press and release ignitor but- ton. This will light pilot. The pilot is attached to the burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 19.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

8.Slightly depress and turn control knob counterclockwise

C-clockwiseto desired heating level. The burner(s) should light.

Set control knob to any heat level between HI and LO.

WARNING: Do not operate heater between PILOT and HI positions.

VARIABLE CONTROL

OPERATION

The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained. Even the lowest setting provides realis- tic, dancing yellow flames. Selecting higher settings produces greater heat output. This results in increased heating comfort.

CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve.

TO TURN OFF GAS

Ignitor Electrode

Pilot Burner

TO APPLIANCE

Shutting Off Heater

1.

Press in and turn control knob clockwise

Clockwise

to the

 

HI position.

 

 

2.

Turn control knob clockwise Clockwise to the pilot position.

3.

Press in control knob and turn clockwise

Clockwise

to the

 

OFF position.

 

 

Thermocouple

Figure 36 - Pilot

Shutting Off Burner(s) Only (pilot stays lit)

1.

Turn control knob clockwise Clockwise to the HI position.

2.

Press in and turn control knob clockwise Clockwise to the

 

pilot position.

For..com

111160-01B

Image 18
Contents CRL2718P/N What to do if YOU Smell GAS18, 24, and 30 Variable CRL3124P/NTable of Contents Safety InformationProduct Identification Product Features AIR for Combustion and Ventilation Local CodesUnpacking Determining FRESH-AIR Flow for Heater Location Confined and Unconfined SpaceDetermining if You Have a Confined or Uncon- fined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Installation Check GAS TypeIf Using Mantel Minimum Noncombustible Material ClearancesFloor Clearances Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Connecting to GAS Supply Attaching Flexible Gas Hose to Heater Gas RegulatorPressure Testing Gas Supply Piping system Checking GAS ConnectionsInstalling Logs Pressure Testing Heater Gas ConnectionsInstalling Back Log #1 Installing Middle Log #2 CCL3930PTB/NTB Shown Installing Crossover Log #6 CCL3930PTB/NTB Shown Single Burner Seasonal Oak Models CRL2718P/N, CRL2718P/NOperating Heater Lighting InstructionsTo Appliance Variable Control OperationTo Turn OFF GAS Shutting Off HeaterManual Lighting Procedure InstructionsThermostat Control Operation Inspecting BurnersTo Turn OFF GAS To Appliance Pilot Flame PatternBurner Primary AIR Holes Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Main BurnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement Optional Positioning of Thermostat Sensing Bulb For Masonry and Factory-built Metal FireplaceService Hints Replacement PartsAccessories Technical ServiceDual Burner Biltmore Split OAK Models SpecificationsDual Burner Smoky Mountain OAK Models Single Burner Seasonal OAK ModelsIllustrated Parts Breakdown Parts List Variable MANUALLY-CONTROLLED Biltmore Split OAK ModelsModels CGD3018PT, CGD3018NT, CGD3924PT and CGD3924NT THERMOSTATICALLY-CONTROLLED Smoky Mountain OAK Models Models CCL3018PTA and CCL3018NTA THERMOSTATICALLY-CONTROLLED Biltmore Split OAK Models KEY Part Number CCL3018PTA CCL3018NTA Description QTYModels CCL3924PTA, CCL3924NTA, CCL3930PTB and CCL3930NTB Parts List Variable Manually Controlled Seasonal OAK CRL3124P and CRL3124NVariable MANUALLY-CONTROLLED Seasonal OAK Models Description QTYParts Central Owners Registration Form Postage Required 111160-01B Warranty Information Keep this Warranty