DIP SWITCH CONFIGURATION CHART

P74042_F1DE108E_man.qxd 5/6/02 10:06 AM Page 16

 

 

 

I N STA L L AT I O N

DIP SWITCH CONFIGURATION CHART

 

 

 

 

 

DIP SWITCH#

 

BANK ADDRESS

DOWN

DOWN

DOWN

DOWN

BANK 00 PRIMARY / SECONDARY (Default)

UP

DOWN

DOWN

DOWN

BANK 01 PRIMARY / SECONDARY

 

 

 

 

 

DOWN

UP

DOWN

DOWN

BANK 02 PRIMARY / SECONDARY

 

 

 

 

 

UP

UP

DOWN

DOWN

BANK 03 PRIMARY / SECONDARY

 

 

 

 

 

DOWN

DOWN

UP

DOWN

BANK 04 SECONDARY

UP

DOWN

UP

DOWN

BANK 05 SECONDARY

 

 

 

 

 

DOWN

UP

UP

DOWN

BANK 06 SECONDARY

 

 

 

 

 

UP

UP

UP

DOWN

BANK 07 SECONDARY

 

 

 

 

 

DOWN

DOWN

DOWN

UP

BANK 08 SECONDARY

UP

DOWN

DOWN

UP

BANK 09 SECONDARY

 

 

 

 

 

DOWN

UP

DOWN

UP

BANK 10 SECONDARY

 

 

 

 

 

UP

UP

DOWN

UP

BANK 11 SECONDARY

 

 

 

 

 

DOWN

DOWN

UP

UP

BANK 12 SECONDARY

UP

DOWN

UP

UP

BANK 13 SECONDARY

 

 

 

 

 

DOWN

UP

UP

UP

BANK 14 SECONDARY

 

 

 

 

 

UP

UP

UP

UP

BANK 15 SECONDARY

 

 

 

 

 

Example: Four KVM Switches (F1DE108B) are daisy-chained together to control 32 computers. The DIP Switch on the Primary Switch is set to “BANK address 00” and the Secondary Switches are each set to a unique BANK (between 01 and 15).

Installation

Before you begin:

1.Make sure that all computers and KVM Switches are powered off and that each KVM Switch has been assigned a unique BANK address.

2.Place all Primary and Secondary Switches in the desired location.

3.Connect the servers to the KVM Switch as previously described for a standalone configuration.

4.Connect the Console monitor, keyboard, and mouse to the Console ports of the Primary KVM Switch(es), as previously described for standalone configuration, skipping steps 5 and 6.

I N STA L L AT I O N

Example of Daisy-Chain Configuration:

 

 

 

 

console

 

 

 

 

bank

 

flash

USB

 

 

 

 

select

daisy chain IN

CPU 01/02

CPU 03/04

CPU 05/06

CPU 07/08

1

2 3

4

 

PS/2

 

 

 

 

 

 

 

 

 

 

 

 

reset

 

 

 

daisy chain OUT

 

 

 

90-264 VAC. 47-63 Hz

 

 

 

 

console

 

 

 

 

bank

 

flash

USB

 

 

 

 

select

daisy chain IN

CPU 01/02

CPU 03/04

CPU 05/06

CPU 07/08

1

2 3

4

 

PS/2

 

 

 

 

 

 

 

 

 

 

 

 

reset

 

 

 

daisy chain OUT

 

 

 

90-264 VAC. 47-63 Hz

 

 

 

 

 

 

 

 

 

 

 

 

console

 

 

 

 

bank

 

flash

USB

 

 

 

 

select

daisy chain IN

CPU 01/02

CPU 03/04

CPU 05/06

CPU 07/08

1

2 3

4

 

PS/2

 

 

 

 

 

 

 

 

 

 

 

 

reset

 

 

 

daisy chain OUT

 

 

 

90-264 VAC. 47-63 Hz

 

 

 

 

console

 

 

 

 

bank

 

flash

USB

 

 

 

 

select

daisy chain IN

CPU 01/02

CPU 03/04

CPU 05/06

CPU 07/08

1

2 3

4

 

PS/2

 

 

 

 

reset

 

 

 

daisy chain OUT

 

 

 

90-264 VAC. 47-63 Hz

 

 

 

 

 

 

 

 

Connecting the Daisy-Chain Cable

5.Using the Daisy-Chain Cable (F1D9402-XX), connect one end to the “Daisy-Chain OUT” port on the first KVM Switch.

6.Connect the other end of the Daisy-Chain Cable to the “Daisy-Chain In” port of the second KVM Switch.

Note: It does not matter which unit is the Primary Switch, only that the cables are always connected “OUT to IN” or “IN to OUT”.

Adding Additional Units

7.Continuing in the same manner, using the Daisy-Chain Cable (F1D9402-XX), connect “Daisy-Chain IN” to “Daisy-Chain OUT” on all subsequent units.