LOCAL CODES

PRODUCT FEATURES

 

PROPANE/LP SUPPLY

 

INSTALLATION

 

Check Gas Type

 

Locating Heater

LOCAL CODES

Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of National Fuel Gas Code, ANSI Z223.1/NFPA 54*.

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

PRODUCT FEATURES

SAFETY PILOT

This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent- free room heaters. The ODS/pilot shuts off the heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM

This heater has a piezo ignitor. This system requires no matches, batteries, or other sources to light heater.

PROPANE/LP SUPPLY

Propane/LP gas and propane/LP tank(s) are to be furnished by the user. The propane/LP cylinder to be used must be constructed and marked in accordance with the specifications for the propane/LP gas cylin- ders of the U.S. Department of Transportation (DOT).

Use this heater only with a propane/LP vapor withdrawal supply system. See Chapter 5 of the Standard for Storage and Handling of Liquefied Petroleum Gas, ANSI/NFPA 58 and/or CAN/CGA B149.2. Your local library or fire department will have this booklet.

The amount of propane/LP gas ready for use from propane/LP tanks varies. Two factors decide this amount:

1.The amount of propane/LP gas in tank(s)

2.The temperature of tank(s)

This heater is designed for use with a 20 or 40 pound refillable propane/LP cylinder when used as a self contained heating system (with hose and regulator). Larger tanks may be used if installed in a permanent gas supply system.

The propane/LP cylinder used must include a collar to protect the cylinder valve, and a listed overfilling prevention device (OPD).

INSTALLATION

CHECK GAS TYPE

Use only propane/LP gas. If your gas supply is not propane/LP, do not install heater. Call dealer where you bought heater for proper type heater.

LOCATING HEATER

WARNING: Maintain the minimum clearances shown in Figure 2. If you can, provide greater clear- ances from floor, ceiling, and joining wall.

WARNING: Never install the heater

in a bathroom

where curtains, furniture, clothing, or other flam- mable objects are less than 36 inches from the front, top, or sides of the heater

as a fireplace insert

in high traffic areas

in windy or drafty areas

CAUTION: This heater creates warm air currents. These currents move heat to wall surfaces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

CAUTION: If you install the heater in a home garage

heater pilot and burner must be at least 18 inches above floor

locate heater where moving vehicle will not hit it

For convenience and efficiency, install heater

where there is easy access for operation, inspection, and service

in coldest part of room

CEILING

36"

Minimum

6" Minimum

From Sides Of

Heater

Right

LeftSide

Side

3" Minimum To Top Surface

Of Carpeting, Tile Or Other

FLOOR Combustible Material

Figure 2 - Mounting Clearances As Viewed From Front of Heater

For..com

110373-01D

Image 4
Contents REM10PT RH10PT Blue Flame VENT-FREE PROPANE/LP GAS HeaterWhat to do if YOU Smell GAS Table of Contents Safety InformationProduct Identification UnpackingProduct Features InstallationLocal Codes PROPANE/LP SupplyInstalling Heater to Wall Thermostat Sensing BulbConnecting to Portable Cylinder GAS Supply Installing Bottom Mounting ScrewConnecting to Permanent GAS Supply Installation ItemsPressure Testing Gas Supply Piping System Permanent GAS SupplyFor Your Safety Read Before Lighting Pressure Testing Heater Gas ConnectionsOperating Heater Checking GAS Connections for Permanent GAS SupplyManual Lighting Procedure To Turn OFF GAS To ApplianceThermostat Control Operation Shutting Off HeaterInspecting Burner StoragePilot Flame Pattern Burner Flame PatternCleaning Maintenance Cleaning Burner Pilot AIR InletODS/PILOT and Burner CabinetTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Illustrated Parts Breakdown Models REM10PT RH10PT PilotParts List KEY Part Number REM10PT RH10PT Description QTYSpecifications Technical ServiceService Hints Service Publications AccessoriesOwners Registration Form Postage Required 110373-01D Warranty Information

REM10PT RH10PT specifications

Desa REM10PT RH10PT is a cutting-edge device that exemplifies innovative engineering in the domain of environmental monitoring and management. Designed to address the increasing demand for smart technology in both urban and rural settings, the REM10PT RH10PT integrates a range of advanced features that allow users to effectively monitor and control their environments.

One of the standout attributes of the REM10PT RH10PT is its exceptional sensor technology. Equipped with high-precision sensors, this device can accurately measure a variety of environmental parameters, including temperature, humidity, air quality, and other critical factors. The real-time data collection ensures that users are kept informed about their surroundings, enabling them to make timely and informed decisions.

The REM10PT RH10PT also boasts a robust connectivity framework. It supports various communication protocols such as Wi-Fi, Bluetooth, and Zigbee, facilitating seamless integration with existing home automation systems. This connectivity allows users to access and manage their devices remotely through a dedicated mobile application, providing convenience and flexibility in monitoring environmental conditions.

Another notable feature of this device is its energy-efficient design. The REM10PT RH10PT is built with sustainability in mind, utilizing low-power components that minimize energy consumption without compromising performance. This not only reduces operational costs but also aligns with the global push for greener technologies.

The user interface is intuitive and user-friendly, offering easy navigation through the device's features and settings. It provides customizable alerts and notifications, allowing users to set parameters according to their specific needs. Whether it’s a simple reminder about humidity levels for plant care or urgent alerts regarding air quality fluctuations, the REM10PT RH10PT delivers pertinent information in real-time.

Lastly, the durability of the REM10PT RH10PT deserves praise. Engineered to withstand varying environmental conditions, the device features weather-resistant housing and high-quality materials that ensure longevity and reliability. This makes it suitable for both indoor applications and outdoor settings, including gardens, farms, and industrial environments.

In summary, the Desa REM10PT RH10PT is an innovative environmental monitoring solution that combines high-precision sensors, robust connectivity, energy efficiency, and user-friendly design. Its versatility and durability make it an essential tool for anyone looking to enhance their awareness and control of environmental conditions. As technology continues to evolve, devices like the REM10PT RH10PT pave the way for a smarter, more connected future.