Desa REM10PT RH10PT installation manual Connecting to Permanent GAS Supply, Installation Items

Page 7

INSTALLATION

Connecting to Portable Cylinder Gas Supply (Cont.) Connecting To Permanent Gas Supply

7

INSTALLATION

Continued

7.Open propane/LP supply valve on propane/LP tank(s) slowly. Note: If not opened slowly, excess-flow check valve on pro- pane/LP tank may stop gas flow. If this happens, close pro- pane/LP supply valve and open again slowly.

8.Check all connections for leaks. Apply a noncorrosive leak detection fluid to gas joints. Bubbles forming show a leak that must be corrected.

9.Close propane/LP supply valve.

CONNECTING TO PERMANENT GAS SUPPLY

WARNING: This appliance requires a 3/8" NPT (National Pipe Thread) inlet connection to the pres- sure regulator.

WARNING: A qualified service person must con- nect heater to gas supply. Follow all local codes.

If installing to a fixed fuel piping system, the installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1.

If the heater will be connected to a permanent gas source, the installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure to between 11 and 14 inches of water. If you do not reduce incoming gas pressure, heater regulator damage could occur. Install the external regulator with the vent pointing down as shown in Figure 12. Pointing the vent down protects it from freezing rain or sleet.

CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of large enough diameter to allow proper gas volume to heater. If pipe is too small, undue loss of volume will occur.

CAUTION: Never connect heater directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane/LP supply.

Installation Items

Propane/LP

Supply

Tank

External

Regulator

Vent

Pointing

Down

Before installing heater, make sure you have the items listed below.

external regulator (supplied by installer)

piping (check local codes)

sealant (resistant to propane/LP gas)

equipment shutoff valve *

ground joint union

test gauge connection *

sediment trap

tee joint

pipe wrench

*A CSA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. The optional CSA design-certified equipment shutoff valve can be purchased from your dealer. See Accessories, page 18.

Figure 12 - External Regulator With Vent Pointing Down

Installation must include equipment shutoff valve, union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13, page 8).

IMPORTANT: Install an equipment shutoff valve in an accessible location. The equipment shutoff valve is for turning on or shutting off the gas to the appliance.

Apply pipe joint sealant lightly to male NPT threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

WARNING: Use pipe joint sealant that is resistant to liquid petroleum (LP) gas.

For morevisit www..com

110373-01D

Image 7
Contents REM10PT RH10PT Blue Flame VENT-FREE PROPANE/LP GAS HeaterWhat to do if YOU Smell GAS Safety Information Table of ContentsUnpacking Product IdentificationPROPANE/LP Supply Product FeaturesInstallation Local CodesThermostat Sensing Bulb Installing Heater to WallInstalling Bottom Mounting Screw Connecting to Portable Cylinder GAS SupplyInstallation Items Connecting to Permanent GAS SupplyPermanent GAS Supply Pressure Testing Gas Supply Piping SystemChecking GAS Connections for Permanent GAS Supply For Your Safety Read Before LightingPressure Testing Heater Gas Connections Operating HeaterShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationBurner Flame Pattern Inspecting BurnerStorage Pilot Flame PatternCabinet Cleaning MaintenanceCleaning Burner Pilot AIR Inlet ODS/PILOT and BurnerObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Models REM10PT RH10PT Pilot Illustrated Parts BreakdownKEY Part Number REM10PT RH10PT Description QTY Parts ListService Publications Accessories SpecificationsTechnical Service Service HintsOwners Registration Form Postage Required 110373-01D Warranty Information

REM10PT RH10PT specifications

Desa REM10PT RH10PT is a cutting-edge device that exemplifies innovative engineering in the domain of environmental monitoring and management. Designed to address the increasing demand for smart technology in both urban and rural settings, the REM10PT RH10PT integrates a range of advanced features that allow users to effectively monitor and control their environments.

One of the standout attributes of the REM10PT RH10PT is its exceptional sensor technology. Equipped with high-precision sensors, this device can accurately measure a variety of environmental parameters, including temperature, humidity, air quality, and other critical factors. The real-time data collection ensures that users are kept informed about their surroundings, enabling them to make timely and informed decisions.

The REM10PT RH10PT also boasts a robust connectivity framework. It supports various communication protocols such as Wi-Fi, Bluetooth, and Zigbee, facilitating seamless integration with existing home automation systems. This connectivity allows users to access and manage their devices remotely through a dedicated mobile application, providing convenience and flexibility in monitoring environmental conditions.

Another notable feature of this device is its energy-efficient design. The REM10PT RH10PT is built with sustainability in mind, utilizing low-power components that minimize energy consumption without compromising performance. This not only reduces operational costs but also aligns with the global push for greener technologies.

The user interface is intuitive and user-friendly, offering easy navigation through the device's features and settings. It provides customizable alerts and notifications, allowing users to set parameters according to their specific needs. Whether it’s a simple reminder about humidity levels for plant care or urgent alerts regarding air quality fluctuations, the REM10PT RH10PT delivers pertinent information in real-time.

Lastly, the durability of the REM10PT RH10PT deserves praise. Engineered to withstand varying environmental conditions, the device features weather-resistant housing and high-quality materials that ensure longevity and reliability. This makes it suitable for both indoor applications and outdoor settings, including gardens, farms, and industrial environments.

In summary, the Desa REM10PT RH10PT is an innovative environmental monitoring solution that combines high-precision sensors, robust connectivity, energy efficiency, and user-friendly design. Its versatility and durability make it an essential tool for anyone looking to enhance their awareness and control of environmental conditions. As technology continues to evolve, devices like the REM10PT RH10PT pave the way for a smarter, more connected future.