Bosch Appliances Model GWH 425 manual Mounting Heater, Screws Incandescent particle tray

Page 7

Installation instructions

3.4Mounting Heater

Warning: before starting installation:

B check that there are no loose parts inside the appliance

B ensure that gas pipe, gas valve, and burner have no damage and are properly fitted.

BRead chapter 2.2 to verify proper gas type and to check all parts are included in box.

Front cover should be removed in order to i inspect components visually (see

instructions below).

Remove cover and inspect.

BRemove the temperature control.

BUnscrew the cover fixing screws, see Fig. 6.

BRemove the outer case by sliding it forwards and then lifting upwards.

BEnsure that the flue terminal is clear.

BAfter inspection, replace front cover and tighten screws.

Install incandescent particle tray.

B Install incandenscent particle tray using screws provided as shown in Fig. 5.

BHang heater on two L shaped hooks. (See Fig. 8).

Fig. 6 Remove front cover

Fig. 7 Support board

Screws

Incandescent particle tray

Fig. 5 Incandescent particle tray illustration

Mounting heater.

The GWH 425 PN is design certified for mounting on a wall.

Warning:

B Do not install this appliance on a carpeted wall.

The heater must be mounted on a wall using

 

appropriate anchoring materials. If wall is a stud wall

 

sheathed with plasterboard, it is recommended that

 

support board(s), either 1x4’s or 1/2" (minimum)

 

plywood first be attached across a pair of studs and

Fig. 8 Secure heater to wall

then the heater should be attached to the support

 

boards, see Fig. 7.

 

BSecure the two included L shaped hooks to wall studs or support board 13 1/4” apart. (See Fig. 7).

6 720 608 034

7

Image 7
Contents GWH-425-PN-N GWH-425-PN-L Index IndexAppliance details GWH 425 PN specifications Technical dataOver heat prevention temperature limiter Water resistant Appliance detailsGeneral rules to follow for safe operation Unpacking the GWH 425 PN heaterDimensions in Inches and mm Dimensions and installation clearancesInstallation instructions Installation instructionsProper location for installing your heater Heater placement and clearancesScrews Incandescent particle tray Mounting HeaterAppliances located in confined spaces Combustion air requirementsVenting Existing interior masonry chimney Installation instructions Masonry chimneyGAS Connections Gas piping & connectionsFor Natural GAS Water connections Connecting manometer Shut off gasConnecting the pressure relief valve PRV Measuring gas pressureOperation instructions For your safety read before operating your water heaterOperation instructions Recirculation applicationTo turn off appliance Lighting instructionsTemperature adjustment knob Setting the water temperatureDraining water from heater Pilot Maintenance and serviceMaintenance intervals Water valveOperate the circulating pump Vent assemblyMain burners Mineral scale build-upPilot goes out during or after hot water use TroubleshootingPilot lights, but goes out when button is released Introduction Pilot does not lightBurners do not light with water flow Hot water temperature fluctuates at tapCheck for a clogged inlet water filter screen see chapter Burners ignite without hot water flow Noise when heater is runningWater is too hot Water is not hot enoughBurners do not operate cleanly yellow flames when operating Protecting the environment Protecting the environmentSaving water resources Interior components and diagram parts list Interior components and diagram parts listInterior components Components Diagram Components diagramDescription Reference Parts listFifteen Year Limited Warranty Waitsfield, VT all rights reserved Bosch Group Bosch Water Heating Mad River ParkSerial Number Gas Pressure Reading Static