Bosch Appliances Model GWH 425 manual Appliance details, GWH 425 PN specifications Technical data

Page 3

Appliance details

2Appliance details

2.1GWH 425 PN specifications (Technical data)

Approved in US/Canada

Capacity

GWH 425 PN: 4.3 GPM

Maximum output

GWH 425 PN: 91 525 Btu/hr

Maximum input

GWH 425 PN: 117 000 Btu/hr

Efficiency in %

Recovery efficiency 78%

Min. Output

GWH 425 PN: 23 906 Btu/hr

Gas Requirement

Gas connection (inches) - ¾” NPT

Inlet gas pressure under maximum operation* Propane: 10.5” - 14” water column Natural Gas: 5.7” - 14” water column.

*To measure Gas Pressure, see Measuring Gas Pressure, chapter 3.8.

Venting Natural Draft

Vent diameter (inches) - 5”

Minimum height (feet) - 6’ with no elbows Vertical termination

Sidewall termination only with AQ4 power vent kit.

Water

Hot water connection (inches) - ½” NPT Cold water connection (inches) - ½” NPT

Water valve material: Polymer (PPS) (Polypropylene Sulfid)

Minimum water flow: 0.5 gallon/minute (1.9 l/m)

Minimum recommended water pressure: 30 PSI (2.07 bar)

Connections:

– Bottom of heater

Dimensions

GWH 425 PN:

Depth (in): 8.66” (220 mm)

Width (in): 18.11” (460 mm)

Height (in): 25.79” (655 mm)

Weight: 35 pounds (16 kg).

Gas types

Natural Gas.

LP Gas

Safety devices

Flame failure device (ionization flame rod sensor) Pressure relief valve (supplied with heater)

Over heat prevention (temperature limiter).

Water resistant

IP X4.

6 720 608 034

3

Image 3
Contents GWH-425-PN-N GWH-425-PN-L Index IndexAppliance details GWH 425 PN specifications Technical dataOver heat prevention temperature limiter Water resistant Appliance detailsGeneral rules to follow for safe operation Unpacking the GWH 425 PN heaterDimensions in Inches and mm Dimensions and installation clearancesInstallation instructions Installation instructionsProper location for installing your heater Heater placement and clearancesScrews Incandescent particle tray Mounting HeaterAppliances located in confined spaces Combustion air requirementsVenting Existing interior masonry chimney Installation instructions Masonry chimneyGAS Connections Gas piping & connectionsFor Natural GAS Water connections Connecting manometer Shut off gasConnecting the pressure relief valve PRV Measuring gas pressureOperation instructions For your safety read before operating your water heaterOperation instructions Recirculation applicationTo turn off appliance Lighting instructionsSetting the water temperature Temperature adjustment knobDraining water from heater Pilot Maintenance and serviceMaintenance intervals Water valveOperate the circulating pump Vent assemblyMain burners Mineral scale build-upPilot goes out during or after hot water use TroubleshootingPilot lights, but goes out when button is released Introduction Pilot does not lightHot water temperature fluctuates at tap Burners do not light with water flowCheck for a clogged inlet water filter screen see chapter Burners ignite without hot water flow Noise when heater is runningWater is too hot Water is not hot enoughBurners do not operate cleanly yellow flames when operating Protecting the environment Protecting the environmentSaving water resources Interior components and diagram parts list Interior components and diagram parts listInterior components Components Diagram Components diagramDescription Reference Parts listFifteen Year Limited Warranty Waitsfield, VT all rights reserved Bosch Group Bosch Water Heating Mad River ParkSerial Number Gas Pressure Reading Static