Bosch Appliances GWH-635-ES manual Minimum exhaust vent size and length, Venting options

Page 11

Appliance details

The appliance should be located as close to the point of termination as possible. The maximum vent length is 26 feet (8 m) with one 90 degree elbow. Subtract 2½ feet from the total vent length for each additional 90° elbow used (a maximum of three 90° elbows are permitted in the total vent length), or subtract 1 ¼ feet for every 45° elbow used. Horizontal sections of vent must pitch ¼" for every foot of horizontal length and be supported at 4 foot intervals with overhead hangers. Any vent section greater than 45 degrees is considered an elbow.

Note: The stainless steel exhaust vent pipe should not be used in concealed or unheated locations. Listed thimbles or collars are necessary to pass through wall and ceiling partitions. If the vent system passes through combustible areas where the vent clearance requirements cannot be maintained, it is permissible to chase straight sections of sealed 3 inch single wall vent through 4 inch (or greater) Type-B vent. The distance to combustibles using this chase technique is 1 inch.

Note: Type-B vent should never be used as the actual exhaust vent system for the appliance, as it is not gas tight.

Minimum exhaust vent size and length

The use of a 90 degree elbow is equivalent to 2 ½ ft in vent length.

The use of 45 degree elbow is equivalent to 1 ¼ ft in vent length.

Fig. 8

Maximum exhaust vent and combustion air inlet lengths

Fig. 9

Note: reduce 2½ ft for each 90° elbow used after the first one, reduce 1 ¼ ft for each 45° elbow.

Vent Safety System

The GWH-635-ES will shut down if inadequate exhaust venting is detected or a lack of combustion air is provided to the unit; see troubleshooting section on page 24. See error code to confirm error, correct the problem and then reset the heater before operating.

Attaching the exhaust and air inlet connection adaptors to the top of the heater

Fig. 10

Fig. 11

BAttach the flue gas exhaust accessory (8 705 504

114)to the top of the unit (position 1) using the 4 screws and gasket provided, and fully insert 3" stainless steel vent pipe into the accessory and tighten the clamp (position 2).

B Attach the combustion air inlet accessory (8 705 504 115) to the top of the unit (position 3) using the 3 screws and gasket provided, and fully insert 3" combustion air pipe into the accessory and tighten the clamp (position 4). NOTE: The appliance has the possibility to mount the combustion air inlet accessory on the top right or on the top left side of the heater. The combustion air inlet that is not used must be kept sealed.

2.9.1Venting options

Installing this water heater as a room sealed (TWIN PIPE SYSTEM) is the recommended method. Contact CEC or dealer for available vent termination kits and vent materials for this water heater.

6 720 607 072

11

Image 11
Contents What to do if you smell gas GWH-635-ES-NGWH-635-ES-L Water heaters for use with Natural and L.P.GFeaturing For your safetyIndex IndexFCC Appliance details FeaturesGWH-635-ES Specifications Technical data Gas types DimensionsSafety devices CombustionDimensions Dimensions and Minimum installation clearancesVenting Proper location for installing your heaterGeneral rules to follow for safe operation Combustion air requirements Mounting installationClearances Venting Room Venting options Minimum exhaust vent size and lengthAppliance details Description Minimum distance 720 607 GAS Line Sizing Gas piping & connectionsFor LP GAS For Natural GASThese Figures are for GWH-635 Gas line sizingInlet Filter Screen Water connectionsWhat to do if YOU Smell GAS For your safety read before operating your water heaterElectrical connections Operating instructionsTo Turn OFF GAS to Appliance Operation instructions PowerTemperature selection Operation instructionsFlow/temperature charts Operation instructions Setting the water temperatureProgram button Use of remote control accessoryReset button OperationTroubleshooting Maintenance and serviceUnbalanced pressure in water lines TroubleshootingTemperature balance valves Chapter Troubleshooting Display Cause SolutionElectrical diagram Electrical diagramGWH-635-ES Functional scheme GWH-635-ES Functional schemeInterior components Interior components diagram and parts listInterior components diagram and parts list Components Diagram Components diagramDescription Reference Parts listAdjusting the unit Special adjustment for measuring and adjusting CO2 levelsLeave Program mode AdjustingComponents Protecting the environmentProtecting the environment PackingFifteen Year Limited Warranty Controlled Energy Corp