2.4General rules to follow for safe operation

B1. You should follow these instructions when you install your heater. In the United States: The installation must conform with local codes or, in the absence of local codes, the National Fuel Gas Code ANSI Z223.1/NFPA 54.

In Canada: The Installation should conform with CGA B149.(1,2) INSTALLATION CODES and /or local installation codes.

B2. Carefully plan where you install the heater. Correct combustion air supply and vent pipe installation are very important. If not installed correctly, fatal accidents can be caused by lack of air, carbon monoxide poisoning or fire.

B 3. When the unit is installed indoors and ROOM SEALED (twin pipe) it is permitted to be located in bathrooms, bedrooms and occupied rooms that are normally kept closed. See chapter 2.9. If the unit will be installed indoors and use indoor combustion air, the place where you install the heater must have enough ventilation. The National Fire Codes do not allow UNSEALED gas fired water heater installations in bathrooms, bedrooms or any occupied rooms normally kept closed. See chapter 2.5 and 2.8.

B 4. You must vent your heater. See section on

VENTING.

B 5. The appliance must be isolated from the gas supply piping system by closing its individual manual gas shutoff valve (not supplied with heater) during any pressure testing at pressures in excess of ½ Psig (3.5 kPa).

The appliance and its gas connection must be leak tested before placing the appliance in operation.

B 6. Keep water heater area clear and free from combustibles and flammable liquids. Do not locate the heater over any material which might burn.

B7. Correct gas pressure is critical for the optimum operation of this heater. Gas piping must be sized to provide the required pressure at the maximum output of the heater, while all the other gas appliances are in operation. Check with your local gas supplier, and see the section on connecting the gas supply.

B8. Should overheating occur or the gas supply fail to shut off, turn off the gas supply at the manual gas shut off valve, on the gas line. Note: manual gas shutoff valve is not supplied with the heater.

B9. Do not use this appliance if any part has been underwater. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been underwater

2.5Proper location for installing your heater

Carefully select the location of the water heater. For your safety and for proper heater operation, you must provide combustion air to the heater and a proper exhaust vent system.

Follow the guidelines below:

B 1. Locate the heater where venting, gas and plumbing connections are feasible and convenient.

B 2. It is strongly recommended that the heater be installed as a ROOM SEALED heater (twin pipe). If the heater will be installed as an UNSEALED heater (single pipe) than National building codes require that you do not install this appliance in bathrooms, bedrooms or any occupied rooms normally kept closed. Heaters that are UNSEALED require a considerable amount of combustion air, see chapter 2.8. If installing the heater UNSEALED within a laundry room, be certain that the dryer is properly vented. Failure to properly vent a dryer could result in a gradual accumulation of lint build up inside the combustion chamber of the heater.

B3. The hot water lines should be kept short to save energy. Centrally locating the water heater is best. It is always best to have hot water lines insulated.

Warning: The water in this water heater is cold and always remains cold except for the times that hot water is being used DO NOT INSTALL IN AN AREA WHERE IT COULD FREEZE. Drain the heater entirely if freezing temperatures are anticipated in area where heater is installed by disconnecting both the inlet and outlet connections at the bottom of heater.

To prevent any freeze damage, introduce short bursts of compressed air (20-40psi) through these connections to remove the residual water in the horizontal pipes and water valve.

Warning: Flammable materials, gasoline, pressurized containers, or any other items or articles that are potential fire hazards must NOT be placed on or adjacent to the heater. The appliance area must be kept free of all combustible materials, gasoline and other flammable vapors and liquids.

6 720 607 072

7

Image 7
Contents What to do if you smell gas GWH-635-ES-NGWH-635-ES-L Water heaters for use with Natural and L.P.GFeaturing For your safetyIndex IndexFCC GWH-635-ES Specifications Technical data FeaturesAppliance details Gas types DimensionsSafety devices CombustionDimensions Dimensions and Minimum installation clearancesGeneral rules to follow for safe operation Proper location for installing your heaterVenting Clearances Mounting installationCombustion air requirements Venting Room Venting options Minimum exhaust vent size and lengthAppliance details Description Minimum distance 720 607 GAS Line Sizing Gas piping & connectionsFor LP GAS For Natural GASThese Figures are for GWH-635 Gas line sizingInlet Filter Screen Water connectionsWhat to do if YOU Smell GAS For your safety read before operating your water heaterElectrical connections Operating instructionsTo Turn OFF GAS to Appliance Operation instructions PowerTemperature selection Operation instructionsFlow/temperature charts Operation instructions Setting the water temperatureProgram button Use of remote control accessoryReset button OperationTroubleshooting Maintenance and serviceTemperature balance valves TroubleshootingUnbalanced pressure in water lines Chapter Troubleshooting Display Cause SolutionElectrical diagram Electrical diagramGWH-635-ES Functional scheme GWH-635-ES Functional schemeInterior components diagram and parts list Interior components diagram and parts listInterior components Components Diagram Components diagramDescription Reference Parts listAdjusting the unit Special adjustment for measuring and adjusting CO2 levelsLeave Program mode AdjustingComponents Protecting the environmentProtecting the environment PackingFifteen Year Limited Warranty Controlled Energy Corp