Appliance details

2.13 Water connections

When facing the heater, the ¾” cold water inlet is on the bottom right and the hot water outlet is on the bottom left. Install the heater centrally in the building if possible and make hot water piping runs as short as possible.

INLET FILTER

SCREEN

allows complete drainage of both the PRV and the line. The location of the PRV must be readily accessible for servicing or replacement, and be mounted as close to the water heater as possible. See Fig. 25. To install the PRV, a suitable fitting connected to an extension on a “T” fitting can be sweated to the hot water line.

Support all piping.

HOT

COLD

 

Fig. 24

Fig. 25 Plumbing Connections and Pressure Relief

B

The use of a union when connecting both water

Valve

 

 

pipes to the inlet and outlet connections is

 

 

recommended, this will facilitate any necessary

 

 

servicing and required cleaning of the inlet water

 

 

particle screen.

 

Although water piping throughout the building may be other than copper, we recommend that copper, galvanized or suitably rated stainless steel flex line piping be used for the water heater connections (follow local codes if more stringent). Never sweat any rigid piping directly to or beneath the water connections, damage can occur to the internal water valve from heating of the pipe. Plastics or other PEX type plumbing line materials are not suitable for connecting directly to the water heater. Keep water inlet and outlet pipes to no less than ¾" (19.05mm) diameter to allow the full flow capacity.

If the cold and hot connections to the heater are reversed, the heater will not function. Be certain there are no loose particles or dirt in the piping. Blow out or flush the lines before connecting to the water heater. Full port valves should be installed on both the cold water supply and hot water outlet lines to facilitate servicing the heater (see Fig. 25). For installation on a private well system with the use of a pressure tank, the lowest pressure range setting recommended is 30-50 psi (2.07 and 3.45bar).

Connecting the pressure relief valve (PRV)

A listed pressure relief valve supplied with the heater must be installed at the time of installation. No valve is to be placed between the PRV and the heater. No reducing coupling or other restriction may be installed in the discharge line. The discharge line must be a minimum of 4” above a drain and installed such that it

18

6 720 607 072

Image 18
Contents Water heaters for use with Natural and L.P.G GWH-635-ES-NGWH-635-ES-L What to do if you smell gasIndex For your safetyIndex FeaturingFCC Features GWH-635-ES Specifications Technical dataAppliance details Combustion DimensionsSafety devices Gas typesDimensions and Minimum installation clearances DimensionsProper location for installing your heater General rules to follow for safe operationVenting Mounting installation ClearancesCombustion air requirements Venting Room Minimum exhaust vent size and length Venting optionsAppliance details Description Minimum distance 720 607 Gas piping & connections GAS Line SizingFor Natural GAS For LP GASGas line sizing These Figures are for GWH-635Water connections Inlet Filter ScreenOperating instructions For your safety read before operating your water heaterElectrical connections What to do if YOU Smell GASTo Turn OFF GAS to Appliance Operation instructions PowerTemperature selection Operation instructionsOperation instructions Setting the water temperature Flow/temperature chartsOperation Use of remote control accessoryReset button Program buttonMaintenance and service TroubleshootingTroubleshooting Temperature balance valvesUnbalanced pressure in water lines Troubleshooting Display Cause Solution ChapterElectrical diagram Electrical diagramGWH-635-ES Functional scheme GWH-635-ES Functional schemeInterior components diagram and parts list Interior components diagram and parts listInterior components Components diagram Components DiagramParts list Description ReferenceSpecial adjustment for measuring and adjusting CO2 levels Adjusting the unitAdjusting Leave Program modePacking Protecting the environmentProtecting the environment ComponentsFifteen Year Limited Warranty Controlled Energy Corp