SERVICE PROCEDURE E32-VI
Heating Element Removal
and Replacement
WARNING
High voltage exposure. Be sure power is “OFF” when performing this procedure.
WARNING
Heater components and stored water may be HOT when performing the following steps in this procedure. Take necessary precaution to prevent personal injury.

Heating Element Removal

1. Turn power “OFF” To water heater.

2. Turn off cold water supply to heater. Connect hose to drain spigot of water heater and route to an open drain. Open a nearby hot water faucet to vent heater for draining. Open drain spigot of water heater and allow heater to drain

to a point below the Element(s).

3. Close drain spigot and remove hose.

3. Remove access cover(s) and insulation.

4.Remove plastic thermostat protector from thermostat(s).

5.Disconnect wires from element terminals.

6.Remove element from tank using 1-½ deep well socket or appropriate wrench. Unscrew element counter-clockwise to remove from tank.

7.Be sure to remove old element gasket from the tank. It is not recommended to be re-used.

Heating Element Replacement

1.Check element terminal block for proper electrical rating. NOTE: Some elements have dual ratings, be sure to check all surfaces of the element terminal block (see illustration below).

2.Apply new element gasket to the new element. Be sure gasket is seated flat against element flange without rolls or gaps (see illustration below).

3.Clean any debris from element fitting on tank. Lubricate element threads as needed with thread lubricant.

4.Thread new element clockwise into tank. Tighten element using 1-½ deep well socket or appropriate wrench. Do not over tighten, over tightening may damage element gasket.

5.Reconnect wires to element, be sure connections are snug and corrosion free. Do not over tighten, doing so may damage terminal block.

6.Resume water supply to heater, be sure tank is full of water and check for leaks.

7.Re-install plastic thermostat protector(s).

8.Re-install insulation and access cover(s).

9.To resume operation, BE SURE TANK IS FULL OF WATER and restore power to water heater. Verify proper heater operation.

 

 

Element Rating.

 

 

Example: (4500 Watt, 240 Volt)

Date Code

 

Element Flange

 

 

 

 

Element Gasket Seated Flat Against

 

 

Element Flange Without Rolls or Gaps

0642

4500W 240V

RC02404524

Terminal

 

 

Block

 

 

 

 

Manufacturer Identification

Page 16

Image 16
Contents Commercial Electric Energy Saver Service Procedure E32 Medium Duty Commercial Electric Water HeatersRED Black RED General InformationRED Full Load Amperes-Phase 1/Phase Input Kw 208V 240V 277V 380V 415V 480VSequence of Operation Sequence of OperationField Conversion for Electrical Phase Conversion Three-Phase to Single-PhaseSingle-Phase to Three-Phase E32 Series Phase Conversion Rating Plate Overlay KitsRating Plate Modification Bradford White CorporationTroubleshooting Making voltage checks to avoid personal InjuryService Procedure E32-I Heating Element TestingHigh voltage exposure. Be sure power is turned OFF to water heater prior to performing thisLine Voltage Testing Service Procedure E32-IILine Voltage Testing Service Procedure E32-III Fuse TestingPersonal injury during this procedure High voltage exposure. Use caution to avoidThermostat Testing Service Procedure E32-IVWater Temperature In Tank Is Above Thermostat Setting Service Procedure E32-V High voltage exposure. Be sure power isOFF when performing this procedure Thermostat ReplacementHeating Element Replacement Heating Element RemovalDip Tube and Anode Inspection Replacement Service Procedure E32-VIIAnode Inspection and Replacement Asse Approved Mixing Valve optional Page Parts@bradfordwhite.com Techserv@bradfordwhite.com
Related manuals
Manual 12 pages 60.05 Kb

Commercial Electric Energy Saver Medium Duty E32 Series Models, E32-80R, E32-50S, E32-120R specifications

Bradford-White Corporation offers a range of high-efficiency water heaters, including the E32 series models: E32-120R, E32-50S, and E32-80R. These models fall under the Commercial Electric Energy Saver Medium Duty category, designed for various commercial applications that require reliable hot water delivery.

The E32 series is built to meet the demands of commercial environments while ensuring energy efficiency. The E32-120R model features a 120-gallon capacity, making it ideal for establishments with high hot water usage. Similarly, the E32-50S offers a 50-gallon capacity, suitable for smaller commercial operations, while the E32-80R provides an 80-gallon option for medium-sized applications. Each model is designed to deliver hot water on demand, with recovery rates optimized for commercial settings.

A notable feature of the E32 series is its Energy Saver technology. These models are equipped with high-efficiency insulation and advanced heating components that minimize heat loss and reduce energy consumption. This not only leads to lower utility bills but also contributes to a reduced carbon footprint, aligning with contemporary environmental standards.

The integration of an advanced electronic control system in the E32 series allows for precise temperature control and monitoring. Users can easily set and adjust water temperatures to meet specific needs, enhancing comfort and safety. Additionally, these models are designed with user-friendly installation features, allowing for straightforward setup and integration into existing systems.

Durability is a hallmark of the E32 series, with each model constructed using high-quality materials that withstand the rigors of commercial use. The tanks are designed to resist corrosion, ensuring a long lifespan and reliable performance. Furthermore, these heaters come with warranties that reflect Bradford-White’s commitment to quality and customer satisfaction.

Maintenance is easy with the E32 series, featuring replaceable heating elements and accessible anodes. This reduces downtime and increases the longevity of the units. Moreover, they comply with all safety and performance regulations, providing peace of mind for business owners.

In summary, the Bradford-White E32-120R, E32-50S, and E32-80R models are versatile, energy-efficient, and durable solutions for commercial hot water needs. Their combination of advanced technology, user-centric features, and robust construction make them a reliable choice for various commercial applications.