Bradford-White Corp BMT2V, BMT2H warranty General Information, Introduction, Model Identification

Page 3

Brute Deluxe (500-2000)

Page 3

 

SECTION 1.

General Information

USING THIS MANUAL – Because Brute Deluxe Boilers and Water Heaters are identical appliances, with the exception of materials of manufacture, labels and ultimate use application, this manual provides information for the proper installation, operation and maintenance of all products. Where differences exist between the application of the appliances and their operation, the sections pertinent to only one appliance or the other will be so identified.

In the Commonwealth of Massachusetts, this app- liance must be installed by a licensed plumber or gas fitter.

WARNING

The Brute Deluxe hydronic boiler or water heater must be installed in accordance with the procedures detailed in this manual, or the Bradford White warranty may be voided. The installation must conform to the requirements of the local jurisdiction having authority, and, in the United States, to the latest edition of the National Fuel Gas Code, ANSI Z223.1/NFPA54. In Canada, the installation must conform to the latest edition of the Natural Gas and Propane Installation Code, CSA B149.1 and/or local codes. Where required by the authority having jurisdiction, the installation of appliances must conform to the Standard for Controls and Safety Devices for Automatically Fired Boilers, ANSI/ASME CSD-1. Any modifications to the unit, its gas controls, or wiring may void the warranty. If field conditions require modifications, consult the factory representative before initiating such modifications.

1.1 Introduction

This manual provides information necessary for the installation, operation, and maintenance of Bradford White Brute Deluxe copper tube appliances. Read it carefully before installation.

All application and installation procedures should be reviewed completely before proceeding with the installation. Consult the Bradford White factory, or local factory representative, with any issues or questions regarding this equipment. Experience has shown that

most operating issues are caused by improper installation.

The Brute Deluxe appliance is protected against over pressurization. A pressure relief valve is fitted to all appliances. It is installed on the outlet header, at the water outlet of the appliance.

IMPORTANT: The inlet gas pressure to the appliance must not exceed 13" W.C. (3.2kPa).

All installations must be made in accordance with: 1). In the U.S., the " National Fuel Gas

Code"ANSI Z223.1/NFPA54, Latest Edition and all applicable local codes as required by the Authorities Having Jurisdiction (AHJ), or

2). In Canada, the "Natural Gas and Propane Installation Code", CSA B149.1, latest edition and

all applicable local codes as required by the AHJ.

All electrical wiring is to be done in accordance with: 1). In the U.S., the "National Electrical Code"

(NEC), ANSI/NFPA 70, latest Edition and all applicable local codes as required by the AHJ, or

2). In Canada, the “Canadian Electrical Code - Part 1”, CSA STD. C22.1 and all applicable local codes as required by the AHJ.

This appliance must be electrically grounded in accordance with the applicable codes and standards referenced above.

1.2 Model Identification

Consult the rating plate on the unit. The following information describes the model number structure.

1-4 Model Series Designation

B M T 2 = Brute Deluxe

4Usage

H = Hydronic

V = Volume Water

5-8 Size

0 5 0 0 = 500,000 BTU/h input

0 7 5 0 = 750,000 BTU/h input

1 0 0 0 = 999,000 BTU/h input

1 2 5 0 = 1,250,000 BTU/h input

1 5 0 0 = 1,500,000 BTU/h input

1 7 5 0 = 1,750,000 BTU/h input

2 0 0 0 = 1,999,000 BTU/h input

1

2

3

4

B

M

T

2

 

 

 

 

5

6

7

8

9

 

10

11

12

 

13

 

 

 

 

 

 

 

 

 

 

A

 

 

C

 

K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

 

15

 

16

17

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SERIES

B M T 2

USAGE

H

V

SIZE

0

5

0

0

0

7

5

0

1

0

0

0

1

2

5

0

1

5

0

0

1

7

5

0

2

0

0

0

FUEL

N

P

ALTITUDE

A

LOCATION

C

FIRING

MODE

K2-Stage

REVISION

 

HEAT

 

OPTIONS

 

PUMP

1

 

EXCHANGER

 

CODE

 

OPTIONS

 

 

K

 

X

 

N

 

 

 

P

 

J

 

BMT2V: H

 

 

S

 

 

 

 

 

 

BMT2H: C

 

 

 

 

 

 

N

 

 

 

 

 

 

BMT2V: B

 

 

 

 

 

 

 

 

 

 

 

Image 3
Contents Brute Deluxe Table of Contents General Information IntroductionModel Identification Clearances WarrantyDimensions Locating the Appliance57¾ 33¾ 16¾ 42545¾ 22¾ 50534¼ 10¼ 80¾ 16¾ 46¼22¾ 58¼ 28¾ 70¼Intake Combustion Air Venting and Combustion AirCombustion Air Combustion Air From RoomCommon Venting Systems VentingVent Categories Category I VentVertical Vent Terminal Locating Vent & Combustion Air TerminalsSide Wall Vent Terminal Side Wall Combustion Air TerminalCombustion Air and Vent Through Side Wall Vertical Combustion Air Terminal Common Vent Test BoilersNatural Gas Supply and PipingVent Terminals for Outdoor Units Natural Propane4A.1 Heating System Piping Hot Supply Connections Boiler Water Connections Boiler4A.4 Freeze Protection Boiler Water Connections Water Heater4A.2 Cold Water Make-Up Boiler 4A.3 Water Flow Requirements Boiler4B.5 Freeze Protection Water Heater Electrical Connections4B.2 Hot Water Supply Piping Water Heater 4B.3 Water Flow Requirements Water HeaterHydronic Piping Multiple Boilers, Primary Secondary System Hydronic Piping One Boiler, Multi-Temperature System Water Heater Piping One Heater, One Tank Water Heater Piping Multiple Heaters, One Tank Water Flow Requirements BMT2V Water Heater Piping Multiple Heaters, Multiple TanksField Wiring Main PowerBrute Deluxe 1000 Wiring Diagram Brute Deluxe 500-750 Connection Diagram Brute Deluxe 1000 Connection Diagram Brute Deluxe 1250-2000 Connection Diagram Filling the System External Staging Control WiringOperating Instructions Sequence of OperationExternal Boiler Operations Operating Temperature ControlOperating the Burner and Set Up Set Up for 0 to 2500 Feet AltitudeHigh Altitude Adjustment and Set Up Shutting Down the Brute Deluxe MaintenanceSystem Maintenance Appliance Maintenance Component DescriptionFilter Manual Reset High Limit ControlTemperature Control Flow SwitchTrouble Shooting Delayed Ignition Possible CausesResolving Lockouts High Gas Consumption Replacement PartsShort Cycling Water Heater Parts List see next Short Cycling BoilerInternal Components See Figure Sheet Metal Components See FigureGas Train Components See Figure Heat Exchanger Components See Figure Electrical Components See Figure Sheet Metal Components Internal Components Brute Deluxe Water Heater Brute Deluxe Hydronic BoilerElectrical Components

BMT2H, BMT2V, Hydronic Boiler, Water Volume Heater specifications

Bradford-White Corporation, a leader in the water heating and hydronic heating industries, offers an impressive range of products designed to meet diverse residential and commercial needs. Among their notable innovations are the BMT2V and BMT2H series hydronic boilers and water volume heaters, which combine state-of-the-art technology with user-friendly features.

The BMT2V and BMT2H models are designed to deliver high-efficiency heating solutions for various applications. One of the key features of these boilers is their superior thermal efficiency, which reduces fuel consumption while ensuring optimal output. With a range of BTU inputs suitable for different heating needs, these boilers can provide efficient heating for residential, commercial, and industrial applications.

Both the BMT2V and BMT2H units are built with advanced combustion technology, allowing for cleaner and more efficient burning of fuel. This not only contributes to lower emissions but also ensures that the boilers operate quietly and reliably. The integrated draft inducer further enhances the efficiency of the combustion process by optimizing airflow, leading to improved overall performance.

Another standout characteristic of these models is their robust construction. Made with high-quality materials, the BMT2V and BMT2H boilers are designed to endure harsh operational conditions while providing long-lasting performance. The tanks are lined with corrosion-resistant coatings, which significantly extend the lifespan of the unit and reduce maintenance requirements.

Both models are also equipped with smart control systems that enable precise temperature regulation and easy monitoring of system performance. These controls allow users to adjust settings remotely or via integrated digital interfaces, further enhancing user convenience. Additionally, the integration of safety features, such as pressure relief valves and automated shut-off systems, ensures safe operation.

The BMT2 series also emphasizes ease of installation and maintenance. Compact designs and flexible venting options allow for versatile installation in various environments. Serviceability is streamlined through easily accessible components, ensuring that technicians can perform maintenance tasks efficiently.

In summary, Bradford-White's BMT2V and BMT2H hydronic boilers and water volume heaters embody efficiency, durability, and advanced technology. With their focus on sustainability and high performance, these models are ideal choices for anyone looking to invest in reliable heating solutions.