Bradford-White Corp ULTRA HIGH EFFICIENCY GAS WATER HEATER Inch 5.1 cm Inch 7.6 cm Inch 10.2 cm

Page 27

Maximum Vent Length:

Direct Vent Maximum Vent Length (Combined Maximum Length for Intake and Exhaust)

Model

Max Vent Length in

Max Vent Length in

Max Vent Length in

feet (meters) for 2

feet (meters) for 3

feet (meters) for 4

Number

inch (5.1 cm)

inch (7.6 cm)

inch (10.2 cm)

 

EFR60T120

60 (18)

120 (36)

170 (51)

Table 3

Note: The venting distance shown in the chart above is the combined maximum distance for the intake and exhaust pipe and elbows. The intake and exhaust vent terminals may be in different locations (i.e., different walls or one wall, one roof) provided the intake equivalent venting distance does not exceed the exhaust by more than 30 feet (9 m).

Determining required vent length:

1.Determine the total length of straight vent pipe (in feet) required for both the intake and the exhaust.

2.Add 5 feet (1.5 m) of venting for every 90° elbow.

3.Add 2 ½ feet (.7 m) of venting for every 45° elbow.

4.Total vent length cannot exceed “Max Vent Length” in Table 3.

5.Air intake cannot exceed exhaust by more than 30 feet (9 m) in any venting situation.

Example of Total Direct Vent Length for EF100T199:

A 3 inch (7.6 cm) venting system has a total of six 90-degree elbows and a total straight pipe length of 65 feet (19.5

m)(includes both intake and exhaust pipe).

Equivalent vent length for elbows: 6 x 5 feet (1.5 m) = 30 feet (9 m).

Total equivalent vent distance = 65 feet (19.5 m) + 30 feet (9 m) = 95 feet (28.5 m) total equivalent vent length. This is below the maximum allowed distance of 100 feet (30 m) for this model using 3 inch (7.6 cm) vent.

NOTICE

Do not include the condensate elbow or vent terminals in determining maximum vent length.

POWER VENT INSTALLATION

Power venting is where the indoor air is used and the exhaust is vented to the outside. Venting may be run horizontally through an outside wall or vertically through a roof through using either 2 inch (5.1 cm), 3 inch (7.6 cm) or 4 inch (10.2 cm) diameter pipe. This water heater is supplied with a 2 inch (5.1 cm) diameter screened intake and exhaust elbow, referred to as the air intake terminal and the exhaust vent terminal.

Power Vent Terminal Location:

Refer to the “Direct Vent Terminal Location” section previously mentioned to determine the proper exhaust vent location. Plan the vent system layout so that proper clearances are maintained from plumbing and wiring.

Vent pipes serving power vented appliances are classified by building codes as “vent connectors”. Required clearances from combustible materials must be provided in accordance with information in this manual under LOCATION OF WATER HEATER, and CLEARANCES, and with National Fuel Gas Code and local codes.

All vent pipes and terminals are to have a 1” minimum clearance to combustibles. DO NOT use the placement of insulation or other materials in the required clearance spaces surrounding the venting to combustible material unless otherwise specified.

Horizontal Installation:

In a horizontal application, it is important that condensate not be allowed to buildup in the exhaust vent pipe. To prevent this from happening, the pipe should be installed with a slight upward slope of ¼ inch (.6 cm) per foot (.3 m). The vent system must be supported every 5 feet (1.5 m) of vertical run and every 3 feet (.9 m) of horizontal run of vent pipe length.

27

Image 27
Contents What to do if YOU Smell GAS With Troubleshooting GuideTable of Contents Page Do not Operate the Appliance Until the Leakage is Corrected If YOU Smell GASDimensions Inches Section II SpecificationsSection III General Information FeaturesTemperature and Pressure Relief Valve Condensate Elbow With Trap Section IV Installation Instructions Unpacking Minimum Clearance To Combustible Material Location Remove CrateAIR Requirements Confined Space Typical Installation IllustrationMechanical Exhausting of Room AIR Unconfined SpaceTypical Front Inlet Connection Typical Two Water Heater Connection Section V Water Connections Instructions for ConnectionsScalding Approximate TIME/TEMPERATURE Relationships in Scalds Approximate Time/Temperature Scald ChartSection VI Venting Approved Venting Materials Page Venting Direct Vent InstallationCanadian US Installations2 Installations1 Clearance above Direct Vent Terminal Clearances Page Typical Horizontal Direct Vent System Typical Vertical Direct Vent System Installation Inch 5.1 cm Inch 7.6 cm Inch 10.2 cm Power Vent InstallationTypical Horizontal Power Vent System Typical Vertical Power Vent System Installation Power Vent Maximum Vent Length Multiple INTAKE/EXHAUST Terminal Separation Distances Concentric Vent Terminal Installation Procedure Vertical InstallationRain Cap to Small Vent Pipe Assembly Concentric Vent Side Wall Attachment Horizontal InstallationVent Pipe Preparation Vent Diameter Dimension MIN MAXInitial Preparation Section VII GAS ConnectionsGAS Pressure Regulation GAS Meter Size Natural Gases onlySection Viii Electrical Connections Wiring Diagram and SchematicSequence of Operation Section IX Operating InstructionsGeneral Instructions To Fill the Water HeaterLighting and SHUT-DOWN Instructions For Your Safety Read Before LightingTemperature Adjustment Water Heater Display and Control Buttons Step To Increase Setpoint TemperatureTo Decrease Setpoint Temperature Changes to C Step Section X Maintenance GeneralBurner Flame Check Sight Glass Location Maintenance ScheduleSediment and Lime Scale Removal Flushing Water HeaterDraining Water Heater Filling Water HeaterAnode Inspection and Replacement Drain Valve and Tank Access PanelRelief Valve Combustion System Inspection Vent and AIR Intake SystemSection XI Diagnostic and Troubleshooting Guide Max Setpoint Next to Temperature  Setpoint value Error Code Shown Water Heater Display SELECT No current error codes Max Setpoint Flashes Exiting Service Mode To Display Flame Sense Current of the Pilot Flame Sensor Display of Water TemperatureTo Display and Change Temperature Setpoint To Display and Change Temperature Format ˚F/˚C Changes to C F/C Flashes Symbol Stops Flashing Resetting Error Codes in Soft Lockout Condition How to reset the control from Lockout ConditionsTo view previous error codes Error Code HistoryError Code Index Stored Error Code For Code Index #9 Exiting SELECTService SETMode Page Procedure for Checking Thermostat Sensors EF Series Water Heater Section XII Parts ListCombustion Surround AssemblyIgnition Control Assembly Combustion Assembly pictured previousPage
Related manuals
Manual 72 pages 6.06 Kb

EFR160T120, ULTRA HIGH EFFICIENCY GAS WATER HEATER specifications

Bradford-White Corporation is a leading manufacturer of residential and commercial water heating solutions, and one of its standout products is the EFR160T120, also known as the EFR-1-60T1206EN. This innovative electric water heater is designed for those seeking reliable performance, energy efficiency, and long-lasting durability.

The EFR160T120 has an impressive capacity of 60 gallons, making it suitable for households with higher hot water demands. This model features a compact design, allowing it to fit into various installation spaces, such as utility rooms or small basements, without compromising on performance. Its vertical configuration and dimensions ensure that it occupies minimal floor space while delivering optimal hot water supply.

One of the most notable features of the EFR160T120 is its high-efficiency electric heating elements. This water heater is equipped with multiple heating elements that provide quick recovery rates, ensuring that hot water is readily available when it is needed most. The intelligent design employs a top-mounted thermostat that allows for accurate temperature control, promoting consistent hot water delivery for showers, baths, and household chores.

In terms of technology, the EFR160T120 incorporates advanced insulation technology that minimizes heat loss, enhancing energy efficiency. This feature not only contributes to reduced energy bills but also lowers carbon emissions, aligning with modern eco-conscious standards. The unit features an integrated temperature and pressure relief valve, which enhances safety by preventing excessive pressure build-up and protecting the tank from potential damage.

Durability is another strong suit of the EFR160T120, as it is constructed from high-quality materials. The tank is coated with a glass lining that protects against corrosion, extending the overall life of the unit. The heater is also backed by Bradford-White's reputation for quality craftsmanship, providing peace of mind for consumers.

Furthermore, the EFR160T120 is designed with user convenience in mind. Maintenance is straightforward, and replacement parts are readily available, which facilitates easy repairs and servicing. Overall, the Bradford-White EFR160T120 water heater stands out as a reliable and efficient choice for homes that require ample hot water supply without sacrificing space or energy efficiency.