Bradford-White Corp EFR160T120, ULTRA HIGH EFFICIENCY GAS WATER HEATER Condensate Elbow With Trap

Page 8

CONDENSATE DRAIN – The water heater should either be raised several inches above the floor on a concrete slab or use a low profile condensate pump to allow free drainage of condensate from the elbow drain fitting. This water heater is a condensing type unit and requires a drain to be located in close proximity to allow the condensate to drain safely.

The condensate drains from the unit at the exhaust elbow located near the bottom of the unit. The preferred connection to the drain fitting is to use a ¾ inch (1.9 cm) elbow sealed with silicone over the outside of the drain outlet and use ¾ inch (1.9 cm) for the drain trap and condensate line to a drain. Use a thick bead of silicone caulk over the outside of the drain outlet connection before assembling the elbow. This is preferred over using the threaded tap because the larger drain line will drain more freely and if too much force is applied to the plastic threads, the fitting may crack and cause a leak. Make sure the condensate drain line slopes down, away from the water heater at least ⅛ inch (.3 cm) per foot (.3

m)toward the drain. The condensate drain pipe must not be routed through an area subject to below freezing temperatures. The condensate build-up will block the exhaust outlet, which will cause improper operation. Refer to Figure 2 for the proper connection of an elbow to the drain outlet and a condensate trap.

Figure 2. Condensate Elbow With Trap

CLEANOUT – All models are equipped with a cleanout opening to aid in removal of hard water deposits from the tank bottom. If this water heater operates under hard water conditions, the following should be performed at least every 3 months: Turn off water supply and drain the water heater. Remove the cleanout jacket cover and tank cover. When cleaning the tank, care must be taken to avoid trying to break deposits loose as this could damage the glass lining and shorten the life of the water heater. After cleaning, re-install the cleanout tank cover and jacket cover, and refill with water. Refer to the section, “Section X: Maintenance” in this Installation and Operating Instruction manual for the procedures for filling and draining the water heater.

SACRIFICIAL ANODES – Four sacrificial anode rods have been installed in the tank head to extend tank life. The anode rods should be inspected periodically for corrosion and replaced when necessary to prolong tank life. Water conditions in your area will influence the time interval for inspection and replacement of the anode rods. The use of a water softener may increase the speed of anode consumption. More frequent inspection of the anodes is needed when using softened (or phosphate treated) water. Contact the installing contractor, or service provider that installed the water heater or the manufacturer listed on the rating plate for anode replacement information.

8

Image 8
Contents With Troubleshooting Guide What to do if YOU Smell GASTable of Contents Page If YOU Smell GAS Do not Operate the Appliance Until the Leakage is CorrectedSection II Specifications Dimensions InchesFeatures Section III General InformationTemperature and Pressure Relief Valve Condensate Elbow With Trap Section IV Installation Instructions Unpacking Minimum Clearance To Combustible Material AIR Requirements LocationRemove Crate Typical Installation Illustration Mechanical Exhausting of Room AIRUnconfined Space Confined SpaceTypical Front Inlet Connection Typical Two Water Heater Connection Scalding Section V Water ConnectionsInstructions for Connections Approximate Time/Temperature Scald Chart Approximate TIME/TEMPERATURE Relationships in ScaldsSection VI Venting Approved Venting Materials Page Direct Vent Installation VentingCanadian US Installations2 Installations1 Clearance above Direct Vent Terminal Clearances Page Typical Horizontal Direct Vent System Typical Vertical Direct Vent System Installation Power Vent Installation Inch 5.1 cm Inch 7.6 cm Inch 10.2 cmTypical Horizontal Power Vent System Typical Vertical Power Vent System Installation Power Vent Maximum Vent Length Multiple INTAKE/EXHAUST Terminal Separation Distances Vertical Installation Concentric Vent Terminal Installation ProcedureRain Cap to Small Vent Pipe Assembly Horizontal Installation Concentric Vent Side Wall AttachmentVent Diameter Dimension MIN MAX Vent Pipe PreparationSection VII GAS Connections Initial PreparationGAS Meter Size Natural Gases only GAS Pressure RegulationWiring Diagram and Schematic Section Viii Electrical ConnectionsSection IX Operating Instructions General InstructionsTo Fill the Water Heater Sequence of OperationFor Your Safety Read Before Lighting Lighting and SHUT-DOWN InstructionsTemperature Adjustment Water Heater Display and Control Buttons To Increase Setpoint Temperature StepTo Decrease Setpoint Temperature Changes to C Step Burner Flame Check Section X MaintenanceGeneral Maintenance Schedule Sight Glass LocationFlushing Water Heater Draining Water HeaterFilling Water Heater Sediment and Lime Scale RemovalRelief Valve Anode Inspection and ReplacementDrain Valve and Tank Access Panel Vent and AIR Intake System Combustion System InspectionSection XI Diagnostic and Troubleshooting Guide Max Setpoint Next to Temperature  Setpoint value Error Code Shown Water Heater Display SELECT No current error codes Max Setpoint Flashes Exiting Service Mode Display of Water Temperature To Display Flame Sense Current of the Pilot Flame SensorTo Display and Change Temperature Setpoint To Display and Change Temperature Format ˚F/˚C Changes to C F/C Flashes Symbol Stops Flashing How to reset the control from Lockout Conditions Resetting Error Codes in Soft Lockout ConditionError Code History To view previous error codesError Code Index Stored Error Code For Code Index #9 Exiting SELECTService SETMode Page Procedure for Checking Thermostat Sensors Section XII Parts List EF Series Water HeaterAssembly Combustion SurroundCombustion Assembly pictured previous Ignition Control AssemblyPage
Related manuals
Manual 72 pages 6.06 Kb

EFR160T120, ULTRA HIGH EFFICIENCY GAS WATER HEATER specifications

Bradford-White Corporation is a leading manufacturer of residential and commercial water heating solutions, and one of its standout products is the EFR160T120, also known as the EFR-1-60T1206EN. This innovative electric water heater is designed for those seeking reliable performance, energy efficiency, and long-lasting durability.

The EFR160T120 has an impressive capacity of 60 gallons, making it suitable for households with higher hot water demands. This model features a compact design, allowing it to fit into various installation spaces, such as utility rooms or small basements, without compromising on performance. Its vertical configuration and dimensions ensure that it occupies minimal floor space while delivering optimal hot water supply.

One of the most notable features of the EFR160T120 is its high-efficiency electric heating elements. This water heater is equipped with multiple heating elements that provide quick recovery rates, ensuring that hot water is readily available when it is needed most. The intelligent design employs a top-mounted thermostat that allows for accurate temperature control, promoting consistent hot water delivery for showers, baths, and household chores.

In terms of technology, the EFR160T120 incorporates advanced insulation technology that minimizes heat loss, enhancing energy efficiency. This feature not only contributes to reduced energy bills but also lowers carbon emissions, aligning with modern eco-conscious standards. The unit features an integrated temperature and pressure relief valve, which enhances safety by preventing excessive pressure build-up and protecting the tank from potential damage.

Durability is another strong suit of the EFR160T120, as it is constructed from high-quality materials. The tank is coated with a glass lining that protects against corrosion, extending the overall life of the unit. The heater is also backed by Bradford-White's reputation for quality craftsmanship, providing peace of mind for consumers.

Furthermore, the EFR160T120 is designed with user convenience in mind. Maintenance is straightforward, and replacement parts are readily available, which facilitates easy repairs and servicing. Overall, the Bradford-White EFR160T120 water heater stands out as a reliable and efficient choice for homes that require ample hot water supply without sacrificing space or energy efficiency.