Bradford-White Corp 238-44219-00J, 44219J instruction manual Venting

Page 11

Venting continued-

This water heater must be connected to a lined masonry chimney or venting system approved by local codes or ordinances. The vent connector used to attach the draft diverter outlet to the chimney or approved vent must be of the same diameter as the draft diverter outlet or larger. For proper venting in certain installations, a larger vent connector may be needed. Consult venting tables in ANSI standard (Z223.1-or latest edition), National Fuel Gas Code and CAN/CGA (B149.1 or B149.2-latest editions) Natural Gas and Propane Installation Code, or local code officials for proper application for your area.

Combustion Air Supply

WARNING

Liquefied petroleum gases/propane gas are heavier than air and will remain at floor level if there is a leak. Basements, crawl spaces, closets and areas below ground level will serve as pockets for accumulation of leaking gas. Before lighting, smell all around the appliance area for gas. Be sure to smell next to the floor.

IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch; do not use any telephone in your building.

Immediately call your gas supplier from a neighbor’s telephone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

DO NOT OPERATE APPLIANCE UNTIL LEAKAGE IS CORRECTED!

IMPORTANT

The flow of combustion and ventilating air must not be obstructed.

Do not block or in any way restrict jacket air inlet slots located at the bottom front of the water heater.

Provide adequate air for combustion and ventilation. An insufficient supply of air will cause recirculation of combustion products resulting in air contamination that may be hazardous to life. Such a condition often will result in a yellow, luminous burner flame, causing carboning or sooting of the combustion chamber, burners and flue tubes with possible damage to the water heater.

When an exhaust fan is installed in the same room with a heater, sufficient openings for air must be provided in the walls. Undersized openings will cause air to be drawn into the room through the chimney, causing recirculation of combustion products.

11

Image 11
Contents What to do if YOU Smell GAS For Your SafetyCongratulations Table of Contents General Information General Information Locating the Water Heater InstallationDo not Operate Appliance Until Leakage is Corrected Installation Locating The Water Heater Minimum Clearances Venting Venting Confined Spaces Without First Being Certain IT is Filled with Water Water ConnectionsInstallation Water Connections Approximate TIME/TEMPERATURE Relationships in Scalds Flame for Testing To Fill the Water Heater General OperationPage Lighting and Shutdown Instructions-Honeywell gas control Thermostat Adjustment White Rodgers gas control Thermostat Adjustment Honeywell gas control Burner Flame Checks Maintenance Maintenance Maintenance LED Status Control Status Probable Cause Troubleshooting ChartTroubleshooting Chart Installation for Potable Water Parts List Drawing Part Name and Description Parts List