WARNING

For protection against excessive temperatures and pressure, install temperature and pressure protective equipment required by local codes, but not less than a combination temperature and pressure relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials as meeting the requirements of the Standard for Relief Valves and Automatic Gas Shutoff Devices for Hot Water Supply Systems, ANSI Z21.22 or the Standard CAN1-4.4. Temperature and Pressure and the Standard CAN1- 4.4, Temperature, Pressure, Temperature and Pressure Relief Valves and Vacuum Relief Valves. The combination temperature and pressure relief valve shall be marked with a maximum set pressure not to exceed the maximum working pressure of the water heater. The combination temperature and pressure relief valve shall also have an hourly rated temperature steam BTU discharge capacity not less than the hourly rating of the water heater.

Install the combination temperature and pressure relief valve into the opening provided and marked for this purpose on the water heater.

Note: Some models may already be equipped or supplied with a combination temperature and pressure relief valve. Verify that the combination temperature and pressure relief valve complies with local codes. If the combination temperature and pressure relief valve does not comply with local codes, replace it with one that does. Follow the installation instructions above on this page.

Install a discharge line so that water discharged from the combination temperature and pressure relief valve will exit within six (6) inches (15.2 cm) above, or any distance below the structural floor and cannot contact any live electrical part. The discharge line is to be installed to allow for complete drainage of both the combination temperature and pressure relief valve and the discharge line. The discharge opening must not be subjected to blockage or freezing. DO NOT thread, plug or cap the discharge line. It is recommended that a minimum clearance of four (4) inches (10.2 cm) be provided on the side of the water heater for servicing and maintenance of the combination temperature and pressure relief valve.

Do not place a valve between the combination temperature and pressure relief valve and the tank.

14

Image 14
Contents For Your Safety What to do if YOU Smell GASCongratulations Table of Contents General Information General Information Installation Locating the Water HeaterDo not Operate Appliance Until Leakage is Corrected Installation Locating The Water Heater Minimum Clearances Venting Venting Confined Spaces Water Connections Without First Being Certain IT is Filled with WaterInstallation Water Connections Approximate TIME/TEMPERATURE Relationships in Scalds Flame for Testing General Operation To Fill the Water HeaterPage Lighting and Shutdown Instructions-Honeywell gas control Thermostat Adjustment White Rodgers gas control Thermostat Adjustment Honeywell gas control Burner Flame Checks Maintenance Maintenance Maintenance Troubleshooting Chart LED Status Control Status Probable CauseTroubleshooting Chart Installation for Potable Water Parts List Drawing Parts List Part Name and Description

44219J, 238-44219-00J specifications

Bradford White Corp is a well-respected name in the water heating industry, known for producing high-quality products designed for durability and efficiency. Among its extensive range of water heaters is the model 238-44219-00J,44219J, which stands out for its impressive features and advanced technologies.

The 238-44219-00J model is a gas water heater that offers high performance and reliability. One of its main characteristics is its heavy-duty, glass-lined tank that enhances corrosion resistance, ensuring a longer lifespan. With a capacity designed to meet the demands of residential and commercial applications alike, this unit is ideal for various hot water needs.

This model incorporates Bradford White's innovative Hydrojet Total Performance System, which enhances the overall efficiency and performance of the water heater. This system includes a specially designed dip tube, which promotes better circulation and minimizes sediment buildup, ultimately leading to improved heating efficiency. The result is quicker recovery rates and a more consistent supply of hot water.

Another notable feature of the 238-44219-00J is its precise temperature control, which is made possible by the advanced gas control system. This control allows users to easily set and maintain their desired water temperature, reducing the risks of scalding and increasing comfort.

The water heater is also equipped with the Defender Safety System, which provides a range of safety features to protect users and properties. This system includes a flame arrestor design, which prevents ignition of flammable vapors, enhancing the overall safety profile of the unit. Additionally, the heater comes with a built-in diagnostics system that alerts users to any performance issues, facilitating timely maintenance.

In terms of installation, this model is designed with flexibility in mind. It can be vented using either direct vent or atmospheric vent systems, allowing for easy integration into various building designs. Its compact size makes it a suitable choice for tight spaces without sacrificing performance.

In summary, the Bradford White Corp 238-44219-00J,44219J gas water heater showcases a blend of durability, efficiency, and advanced technology. With its robust construction, high-performance features, and safety systems, it represents a reliable choice for those in need of a dependable hot water solution. The model exemplifies Bradford White's commitment to delivering innovative and efficient water heating solutions for both residential and commercial customers.