TROUBLESHOOTING CHART (CONTINUED)
LED Status | Control Status | Probable Cause | |
Six flashes and three | Water leak detected by | Excessive amount of water in drain | |
accessory module (some | |||
second pause. | pan/water dam. | ||
models). | |||
|
| ||
|
|
| |
|
| 1. Verify control is not wet or | |
|
| physically damaged. | |
|
| 2. Turn set point knob to "OFF" | |
Seven flashes and three | Gas valve electronic fault | position. Turn set point knob | |
second pause. | detected. | to "PILOT" position and light | |
|
| pilot. | |
|
| 3. Replace gas valve if seven | |
|
| flash error persists. | |
|
| 1. Pilot valve stuck in open | |
|
| position | |
Eight flashes and three |
| 2. Turn set point knob to "OFF" | |
False pilot flame present. | position. Turn set point knob to | ||
second pause | |||
| "PILOT" position and light pilot. | ||
|
| ||
|
| 3. Replace gas valve if eight flash | |
|
| error persists. |
27