SECTION 3.

Operation

3.1 Controls - General

See Figure 15 for control locations.

3.1.1Electronic Ignition Controls:

a.Intermittent Ignition:

3.1.3High Limit Controls:

The manual reset high limit switches are provided as standard equipment on all heaters. Automatic reset switches are optionally provided. The temperature sensing bulb of the switch is always located in the heater outlet. Burners will automatically shut down whenever overheating of water occurs.

3.1.4Flow Switch:

Pilots are automatically lit when the operating aquastat calls for heat (System #9).

The unit performs its own safety check and opens the main valves only after the pilot is proven to be lit. Whenever the pilot flame is interrupted, the main gas valve closes within 0.8 seconds.

b.Electronically Supervised Standing Pilot System (System #16):

When pilot flame fails, the ignition control module responds in less than 0.8 seconds and provides 100% safety shutdown.

3.1.2Operating Controls:

Electrically Operating Controls:

Copper Brute units are equipped with operating temperature. The temperature sensing bulb is located in the heater inlet.

Standard on all models, the switch is mounted directly in the header outlet. The flow switch shuts down all burners in case of low water condition or pump failure.

3.1.5Low Water Cut Off: (Optional)

The low water cut off automatically shuts off the heater whenever the water level drops below the probe. The probe is located at the heater inlet.

3.2Initial Start-Up

Before placing the heater in operation, be certain

that the heater is filled with water and all air is purged from the system. Once the heater is connected to the gas supply, the automatic safety shutoff devices must be checked.

1.Before beginning the tests, make sure the main manual gas valve, and any other heater firing valves are in the “OFF” position.

Rating Plate

Flow Switch

 

 

Pressure Relief

Ignition Control

 

 

Valve

Manual

 

In

 

 

Pilot

 

 

Valve

Out

 

 

 

Manual

 

Transformer

Main Gas

 

 

Valve

 

Terminal Strip

 

 

Safety

 

Operating Control

Gas

 

(Aquastat)

Valve

 

 

Operating

Hi-Limit

 

Gas Valve

 

Figure 15. Control Components.

Image 14
Contents Copper Brute Table of Contents Heater Identification General InformationIntroduction Flow RequirementsInstallation of Indoor Heaters InstallationHeater Placement Water ChemistryClearance Indoor Outdoor From Inches Venting Heater Each Opening Model Square InchesInstallation of Outdoor Heaters Gas Supply and PipingElectrical Wiring Water Piping of SystemPump Performance and Installation Water ExpansionTank Installation Water PressureTwo-Temperature System WithDrain Pump 140F Water 180F Return From Bldg With Horizontal Tank To DrainInitial Start-Up OperationControls General Hi-Limit Checkout To set the temperature and high- limit controlsTo Start Up System Start Up HeaterTo Shut Down System MaintenanceTo Turn Off Heater Indoor ModelsTroubleshooting and Analysis Service Problems Heater will not FireIII. Water Dripping Firebox This page intentionally left blank Bradford White

500-1825 specifications

Bradford-White Corporation is renowned for manufacturing high-quality water heating solutions, and the model 500-1825 is a prime example of the company's commitment to innovation and durability. This water heater is particularly well-suited for residential and commercial applications, providing users with efficient and reliable hot water.

One of the key features of the Bradford-White 500-1825 is its robust construction. Built with high-quality materials, it boasts a glass-lined tank that ensures maximum protection against corrosion. This feature extends the lifespan of the unit significantly, providing users with a long-lasting solution for their hot water needs. The tank's insulation is designed to minimize heat loss, thereby enhancing the unit's energy efficiency and lowering operating costs.

The 500-1825 model employs advanced heating technologies that facilitate rapid heating and recovery rates. It is equipped with a powerful burner system that ensures a quick restoration of hot water even during peak usage times. This feature is particularly beneficial for larger households and commercial environments where hot water demand can be substantial.

Another standout characteristic of the Bradford-White 500-1825 is its user-friendly controls. The model typically includes a smart thermostat that allows users to precisely set and maintain their desired water temperature. This functionality not only enhances comfort but also contributes to energy savings, as the system operates according to the specific needs of the user.

Safety features are paramount in the design of the 500-1825. The unit often includes multiple safety mechanisms, such as a combination temperature and pressure relief valve. This ensures that the water heater operates within safe parameters, providing peace of mind for homeowners and businesses alike.

Additionally, Bradford-White's commitment to innovation is evident in their focus on sustainability. The 500-1825 is designed to meet or exceed stringent energy efficiency standards. This means that users can enjoy the benefits of significant energy savings while reducing their environmental footprint.

In conclusion, the Bradford-White 500-1825 water heater exemplifies the company's dedication to quality, efficiency, and safety. With its durable construction, advanced heating technologies, user-friendly controls, and emphasis on sustainability, it stands out as a reliable choice for those in need of effective hot water solutions. Whether for residential use or commercial applications, the 500-1825 continues to be a trusted option among consumers.