Bradford-White Corp 500-1825 warranty Installation of Outdoor Heaters, Gas Supply and Piping

Page 7

Internet Version for Reference Only

B4 Volume Water Heater

Page 7

 

 

 

 

3.Avoid using long horizontal runs of the vent pipe, and too many 90° elbows, reductions or restrictions. Horizontal runs should have at least a 1/4" rise per foot in the direction of flow. A vent connector should be supported for the design and weight of the material used to maintain clearances and prevent physical damage and separation of joints.

4.Avoid ending heater vents near air conditioning or air supply fans. The fans can pick up exhaust flue products from the heater and return them inside the building, creating a possible health hazard. A minimum of 4 feet horizontal distance must be maintained from electrical meters, gas meters, and relief equipment.

5.Always use double-wall or insulated vent pipe (Type B or equivalent). In cold weather, uninsulated outside vents can chill the rising flue products, blocking the natural draft action of the venting system. This can create a health hazard by spilling flue products into the heater room.

6.Avoid oversize vent piping or extremely long runs of the pipe which may cause excessive cooling and condensation. Rule of Thumb: The total length of the vent, including the connector and any offset, should not exceed 15 feet for every inch of vent diameter. Longer total lengths shown in venting tables are based on maximum capacity, not condensation factors.

7.When the installation of a draft fan is necessary in connecting a venting system to a the heater, the installation should be engineered by competent personnel following good engineering practices. The draft fan supplier should be consulted for correct size. The installation should be in accordance with the latest edition of ANSI Z223.1 and/or, in Canada, CSA

B149.1 requirement and any local codes having jurisdiction. When a draft fan is installed, a suitable draft switch must be wired into the heater control circuit at terminal designated “Field Interlock” to prevent firing of the heater unless a positive draft has been established.

2.3 Installation of Outdoor Heaters

1.Locate the heater to provide the minimum clearances as listed in Table 1, “Placement of Heater”.

2.Do not place the heater in an enclosure or wall recess. Avoid locations where wind deflection off structures might cause down draft. When such wind conditions are possible, place the heater at least three (3) feet from the structures.

3.Never install the heater under any kind of roof overhang. Do not place the heater below or adjacent to any doors, windows, louvers, grills,

Window

Or Grill

Indoor

Room

Figure 7. Incorrect Outdoor Installation.

etc. which connect in any way with an inhabited area of a building. This includes other structures such as garages or utility rooms (see Figure 7).

4.Although these models are CSA designed certified for outdoor installations, such installations are not recommended in areas where the danger of freezing exists unless proper precautions are taken for freeze protection.

2.4Gas Supply and Piping

Review the following instructions before

proceeding with the installation.

1.Verify that the heater is fitted for the proper type of gas by checking the rating plate. Bradford White heaters are normally equipped to operate below a 2000 foot altitude. Heaters equipped to operate at higher altitudes have appropriate stickers or tags attached.

Note: These figures are for Natural Gas (.65 Sp. Gr.), and are based on 1/2" water column pressure drop. Check supply pres- sure with a manometer, and local code requirements for varia- tions. For LPG, reduce pipe diameter one size, but maintain a 1" minimum diameter. A normal number of Tees and elbows have been taken into allowance.

Table 3. Gas Piping Sizes.

Image 7
Contents Copper Brute Table of Contents Flow Requirements General InformationIntroduction Heater IdentificationWater Chemistry InstallationHeater Placement Installation of Indoor HeatersClearance Indoor Outdoor From Inches Heater Each Opening Model Square Inches VentingGas Supply and Piping Installation of Outdoor HeatersWater Piping of System Electrical WiringWater Expansion Pump Performance and InstallationWater Pressure Tank InstallationWith Two-Temperature SystemDrain Pump 140F Water 180F Return From Bldg To Drain With Horizontal TankControls General OperationInitial Start-Up Start Up Heater To set the temperature and high- limit controlsTo Start Up System Hi-Limit CheckoutIndoor Models MaintenanceTo Turn Off Heater To Shut Down SystemHeater will not Fire Troubleshooting and Analysis Service ProblemsIII. Water Dripping Firebox This page intentionally left blank Bradford White

500-1825 specifications

Bradford-White Corporation is renowned for manufacturing high-quality water heating solutions, and the model 500-1825 is a prime example of the company's commitment to innovation and durability. This water heater is particularly well-suited for residential and commercial applications, providing users with efficient and reliable hot water.

One of the key features of the Bradford-White 500-1825 is its robust construction. Built with high-quality materials, it boasts a glass-lined tank that ensures maximum protection against corrosion. This feature extends the lifespan of the unit significantly, providing users with a long-lasting solution for their hot water needs. The tank's insulation is designed to minimize heat loss, thereby enhancing the unit's energy efficiency and lowering operating costs.

The 500-1825 model employs advanced heating technologies that facilitate rapid heating and recovery rates. It is equipped with a powerful burner system that ensures a quick restoration of hot water even during peak usage times. This feature is particularly beneficial for larger households and commercial environments where hot water demand can be substantial.

Another standout characteristic of the Bradford-White 500-1825 is its user-friendly controls. The model typically includes a smart thermostat that allows users to precisely set and maintain their desired water temperature. This functionality not only enhances comfort but also contributes to energy savings, as the system operates according to the specific needs of the user.

Safety features are paramount in the design of the 500-1825. The unit often includes multiple safety mechanisms, such as a combination temperature and pressure relief valve. This ensures that the water heater operates within safe parameters, providing peace of mind for homeowners and businesses alike.

Additionally, Bradford-White's commitment to innovation is evident in their focus on sustainability. The 500-1825 is designed to meet or exceed stringent energy efficiency standards. This means that users can enjoy the benefits of significant energy savings while reducing their environmental footprint.

In conclusion, the Bradford-White 500-1825 water heater exemplifies the company's dedication to quality, efficiency, and safety. With its durable construction, advanced heating technologies, user-friendly controls, and emphasis on sustainability, it stands out as a reliable choice for those in need of effective hot water solutions. Whether for residential use or commercial applications, the 500-1825 continues to be a trusted option among consumers.