American Water Heater ULTRA LOW NOx SERIES 104, 381T1206NOX Minimum Clearances, BCL Venting

Page 14

Venting

INSTALLATION – VENTING CATEGORY AND MATERIALS

 

 

BCL VENTING

Category I

Non-condensing, negative pressure in vent, below atmospheric.

Type venting

Must be installed Conventional Vent; uses room air for combustion and discharges flue

 

 

gases to the outdoor atmosphere through one pipe.

Vent materials

B Vent.

MINIMUM CLEARANCES

This water heater is approved for installation on combustible flooring in an alcove with minimum clearance from combustion construction as indicated in below Figure and Table.

In all installations the minimum combustible clearances from vent piping shall be 6” (15.2 cm). Vent piping passing through a combustible wall or ceiling must be a continuous run (no joints) and retain 6” (15.2 cm) clearance unless an approved reducing thimble is used.

A service clearance of 24” (61 cm) should be maintained from serviceable parts, such as Temperature- pressure relief valves, baffles, digital thermostats, cleanout openings or drain valves.

The units are approved for installation with side, rear and ceiling clearances as indicated below:

MINIMUM CLEARANCES TO COMBUSTIBLE OR NON-COMBUSTIBLE CONSTRUCTION:

MODELS

"A" RIGHT SIDE

"B" LEFT SIDE

"C" BACK

"D" CEILING

BCL-120, 154, 180,

0"

0"

0"

12"

199, 250

0 cm

0 cm

0 cm

30.5 cm

12

Servicing should only be performed by a Qualified Service Technician

Image 14
Contents Commercial GAS Water Heaters For Models BCLPage Table of Contents Introduction Service WarningService Reminder QualificationsTools Required Multiple Appliance Installations Installation ConsiderationsGas and Electrical Characteristics GAS Pressure RequirementsAIR Supply MAKE-UP AIR Direct Communication with Outdoors Contaminated AIRClosed Water Systems Power SupplyAIR Requirements Thermal ExpansionFeatures and Components Blower and Burner Assembly Burner ReplacementPage Spark Igniter Spark Igniter, Flame Sensor, Sight GlassSpark Igniter / Flame Sensor / Control Timing Flame SensorMinimum Clearances Installation Venting Category and MaterialsVenting BCL VentingExterior Clearances Venting Tables Technical Venting Data Type B GAS VentOperation and Service Sequence of OperationSequence of Operation Flow Chart YESFor Your Safety Read Before Operating Lighting and Operating LabelTroubleshooting Complaint Cause Remedy User Qualified AgencyControls Overview Control BOX Assembly Pressure Switches All ModelsHigh Limit SWITCH/ Digital Thermostat Display Lights Digital Thermostat LED Indication Action StatusThen Continuity Check of High Limit ECOConditions Ohms Upper Temperature Probe Continuity CheckOhms Resistance Table Lower Temperature Probe Continuity Check Wiring Terminals Description Ignition ControlFlame FAILURE- Recycle Mode Start UP/ Flame RECOVERY/ Safety LockoutStart UP Heat Mode Failure to Light LockoutInternal Control Failure Fault ConditionsTroubleshooting Guide for Ignition Control Flame Sensor Current CheckPIN Connections PIN Number Description UGB Blower Speed ControlSW2 SW4 Used for Wiring Diagram American Water Heaters

381T1546NOX, 395T1996NOX, BCL, 381T1206NOX, 395T2506NOX specifications

The American Water Heater Ultra Low NOx Series represents a significant advancement in water heating technology, aiming to meet stringent environmental regulations while delivering reliable hot water for residential applications. Models such as the 104,395T1806NOX, 395T2506NOX, 381T1206NOX, and BCL are designed to prioritize efficiency, performance, and compliance with the latest emission standards.

One of the defining features of the Ultra Low NOx Series is its innovative combustion technology. These water heaters utilize a state-of-the-art gas burner that dramatically reduces nitrogen oxide (NOx) emissions, ensuring compliance with local and federal regulations. This technology not only benefits the environment but also contributes to improved indoor air quality.

Efficiency is a hallmark of the Ultra Low NOx Series, with models designed to maximize energy savings while delivering consistent hot water. They feature a user-friendly, adjustable thermostat, providing homeowners with the ability to set their desired water temperature for optimal comfort. In addition, the insulation on these water heaters is designed to minimize heat loss, ensuring that energy consumption is kept to a minimum.

The Ultra Low NOx models are equipped with an easy-to-use digital control panel that allows homeowners to monitor and adjust settings with ease. This convenience is enhanced by advanced diagnostics, which provide real-time alerts regarding system performance and maintenance needs. This proactive approach helps extend the lifespan of the unit and enhances reliability.

Safety is another crucial characteristic of the Ultra Low NOx Series. Each model is equipped with safety features such as a flame rollout switch and a fully automatic gas shut-off, which ensure that the system operates safely under various conditions.

In terms of installation and maintenance, these models are designed with user-friendly features, making the process simpler for technicians. The compact design allows for flexible installation options, even in tighter spaces.

Overall, the American Water Heater Ultra Low NOx Series, including the 104,395T1806NOX, 395T2506NOX, 381T1206NOX, and BCL models, represents an excellent choice for homeowners seeking an efficient, reliable, and environmentally responsible water heating solution. With a focus on reducing emissions and enhancing performance, these models are built to meet the demands of today's conscientious consumers.