American Water Heater (A)BCG38T500-8P manual Make-up Air Direct Communication with Outdoors

Page 8

INSTALLATION CONSIDERATIONS

Make-up Air: Direct Communication with Outdoors

A fresh supply of make-up air for combustion can be supplied to the water heater through make-up air ducts, which directly communicate with the outdoors. (Not Direct Vent.)

Two openings are required: one within 12 inches of the top of the enclosure and one within 12 inches of the bottom of the enclosure. Each opening must have a free area of not less than 1 square inch per 4,000 BTUH of the total input of all appliances within the enclosure. The lower opening primarily provides combustion air. The upper opening provides vent dilution air and acts as a relief opening for flue gases should the vent become obstructed or a downdraft condition occur.

Figure 3

Additionally, when the water heater is installed in a confined space and communicating with the outdoor air, one permanent opening, beginning within 12 inches (30 cm) of the top of the enclosure, must be permitted where the equipment has clearances of at least 1 inch (2.5 cm) from the sides and back, and 6 inches (16 cm) from the front of the appliance. The opening must directly communicate with the outdoors and must communicate through a vertical or horizontal duct to the outdoors or spaces (crawl or attic) that freely communicate with the outdoors, and must have a minimum free area of a) 1 square inch per 3,000 BTUH (7cm2 per kW) of the total input of all equipment located in the enclosure and b) not less than the sum of the areas of all vent connectors in the confined space.

Servicing should only be performed by a Qualified Service Agent

8

Image 8
Contents Commercial GAS Water Heaters Models ABCG385T500-8NCommercial GAS Water Heater Table of Contents Service Warning Service ReminderIntroduction QualificationsTools Optional RequirementsTools Required Installation Considerations Water PipingGAS Pressure Requirements Closed Water SystemsAIR Requirements Air SupplyInstallation Considerations Make-up Air Direct Communication with Outdoors Clearances Water Heater Contaminated AirClearances Exterior Minimum Clearances to Combustible SurfacesVenting Operation and Service Sequence of OperationElectrical Sequence Wiring Diagram 1a 1 1bOperating Sequence Flow Chart YESGAS Control Valve Measuring Gas PressuresManifold Pressure Adjustment Main Valve Solenoid ConnectionsGAS Control VALVE/BURNER Area View HOT Surface Igniter HSIBlower Prover Switch Settings Blower Prover Switch TableThermostat and Ignition Control Board View White Rodgers Integrated Control Thermostat White Rodgers Ignition Control BoardPRE-SERVICE Checklist System has locked out after 3 trials for ignition TroubleshootingIgnition Control Board Error Codes Reversed polarity in power supply Igniter not sensed and/or water heater not grounded Internal control board failureIntegrated Heater Control Display Lights LED Indication Action StatusThen Test 1 120 VAC to Heater CheckConditions Test 2 Polarity Check Test 3 Continuity Check of High Limit ECO Test 4 Upper Temperature Probe Continuity Check OhmsTest 5 Calling for Heat no Blower Operation Test 6 Blower ON, no Ignition E4 Plug Test 8 Igniter HEATS, no Main Burner Test 9 Igniter HEATS, no Main Burner Test 10 Main Burner Ignition for Less than Five Seconds Test 11 Water Heater Shutting OFF below Setting Page

(A)BCG38T500-8P, (A)BCG385T500-8N specifications

The American Water Heater (A)BCG38T500-8P and (A)BCG385T500-8N are innovative options in the realm of residential water heating systems. Designed for efficiency and reliability, these water heaters are perfect for households looking for robust hot water solutions.

One of the primary features of these models is their 38-gallon capacity, which makes them suitable for medium to large households. They provide an ample supply of hot water for everyday needs such as showers, dishwashing, and laundry. With a powerful 50000 BTU gas burner, both models can heat water effectively, ensuring that users have access to hot water when they need it.

In terms of technology, both the (A)BCG38T500-8P and (A)BCG385T500-8N are designed with advanced, environmentally-friendly features. Their efficient design helps reduce energy consumption, making them compliant with Energy Star standards. This not only ensures that users save on utility bills but also contributes to a more sustainable approach to water heating.

The construction of these water heaters is robust, typically featuring a glass-lined tank to prevent corrosion and extend the lifespan of the unit. The exterior is designed to withstand the rigors of time while providing excellent insulation to minimize heat loss. Both models are also equipped with a durable anode rod that further enhances corrosion resistance.

Safety is another critical characteristic of the (A)BCG38T500-8P and (A)BCG385T500-8N. They include safety features such as a temperature and pressure relief valve, ensuring that the system operates safely under various conditions. Additionally, these models often come with a 6-year limited warranty, providing peace of mind for homeowners.

Installation is straightforward, as these water heaters are designed to fit standard plumbing setups. They also offer a range of adjustable settings, allowing homeowners to customize their hot water experience according to their specific needs.

In summary, the American Water Heater (A)BCG38T500-8P and (A)BCG385T500-8N stand out for their ample capacity, energy-efficient operation, durable construction, and safety features. They represent a reliable choice for those seeking effective and long-lasting water heating solutions in their homes.