American Water Heater (A)BCG38T500-8P, (A)BCG385T500-8N manual AIR Requirements, Air Supply

Page 6

INSTALLATION CONSIDERATIONS

Table 1

 

NATURAL GAS

PROPANE (LP) GAS

Maximum Supply Gas Pressure

10” W.C. (2.49 kPa)

12” W.C. (2.99 kPa)

Minimum Supply Gas Pressure

5.2” W.C. (1.29 kPa)

11” W.C. (2.74 kPa)

* Manifold Gas Pressure

3.5” W.C. (0.87 kPa)

10” W.C. (2.49 kPa)

Maximum supply pressure; readings are taken while gas is not flowing (static pressure) AND while gas is flowing (dynamic pressure). Supply pressure must never exceed this maximum value.

Minimum supply gas pressure; readings are taken while gas is not flowing (static pressure) AND while gas is flowing (dynamic pressure). Supply pressure must never fall below the minimum values. Supply gas pressures should be measured with all gas fired appliances conencted to a common main firing at full capacity. If supply pressure drops more than 1.5” W.C. as gas begins to flow, the supply gas system (gas line/regulator) may be restricted or undersized. See the instruction manual for more information.

*Manifold gas pressure; reading can only be taken while gas is flowing. Reading taken should be ± 0.3” W.C. of the listed value. These water heaters are certified for use without modification for altitudes up to 10,000 feet. For elevations above 10,000 feet (3,048 meters), see High Altitude Installations section of instruction manual.

AIR REQUIREMENTS

Carefully review the requirements for combustion and ventilation air in the instruction manual that came with the water heater. Failure to meet these requirements when the water heater is installed or overlooking their importance when servicing the water heater often results in operational problems (some are listed below), needless down time, unnecessary parts replacement, and customer dissatisfaction.

Ensure additional air for combustion and ventilation is provided when additional gas fired appliances are installed to increase hot water supply in an existing location.

Air Supply

Stoichiometric or theoretical complete combustion requires 10 cubic feet of air per 1,000 BTUH of gas supplied. The National Fuel Gas Code also recommends an additional 2.5 cubic feet of “excess” air. For information on minimum make-up air opening sizes for various building installations, refer to the National Fuel Gas Code NFPA 54, ANSI Z223.1.

Figure 1

Servicing should only be performed by a Qualified Service Agent

6

Image 6
Contents Commercial GAS Water Heaters Models ABCG385T500-8NCommercial GAS Water Heater Table of Contents Introduction Service WarningService Reminder QualificationsRequirements Tools RequiredTools Optional GAS Pressure Requirements Installation ConsiderationsWater Piping Closed Water SystemsAIR Requirements Air SupplyInstallation Considerations Make-up Air Direct Communication with Outdoors Clearances Water Heater Contaminated AirClearances Exterior Minimum Clearances to Combustible SurfacesVenting Operation and Service Sequence of OperationElectrical Sequence Wiring Diagram 1a 1 1bOperating Sequence Flow Chart YESGAS Control Valve Measuring Gas PressuresManifold Pressure Adjustment Main Valve Solenoid ConnectionsGAS Control VALVE/BURNER Area View HOT Surface Igniter HSIBlower Prover Switch Settings Blower Prover Switch TableThermostat and Ignition Control Board View White Rodgers Integrated Control Thermostat White Rodgers Ignition Control BoardPRE-SERVICE Checklist Troubleshooting Ignition Control Board Error CodesSystem has locked out after 3 trials for ignition Reversed polarity in power supply Igniter not sensed and/or water heater not grounded Internal control board failureIntegrated Heater Control Display Lights LED Indication Action StatusTest 1 120 VAC to Heater Check ConditionsThen Test 2 Polarity Check Test 3 Continuity Check of High Limit ECO Test 4 Upper Temperature Probe Continuity Check OhmsTest 5 Calling for Heat no Blower Operation Test 6 Blower ON, no Ignition E4 Plug Test 8 Igniter HEATS, no Main Burner Test 9 Igniter HEATS, no Main Burner Test 10 Main Burner Ignition for Less than Five Seconds Test 11 Water Heater Shutting OFF below Setting Page

(A)BCG38T500-8P, (A)BCG385T500-8N specifications

The American Water Heater (A)BCG38T500-8P and (A)BCG385T500-8N are innovative options in the realm of residential water heating systems. Designed for efficiency and reliability, these water heaters are perfect for households looking for robust hot water solutions.

One of the primary features of these models is their 38-gallon capacity, which makes them suitable for medium to large households. They provide an ample supply of hot water for everyday needs such as showers, dishwashing, and laundry. With a powerful 50000 BTU gas burner, both models can heat water effectively, ensuring that users have access to hot water when they need it.

In terms of technology, both the (A)BCG38T500-8P and (A)BCG385T500-8N are designed with advanced, environmentally-friendly features. Their efficient design helps reduce energy consumption, making them compliant with Energy Star standards. This not only ensures that users save on utility bills but also contributes to a more sustainable approach to water heating.

The construction of these water heaters is robust, typically featuring a glass-lined tank to prevent corrosion and extend the lifespan of the unit. The exterior is designed to withstand the rigors of time while providing excellent insulation to minimize heat loss. Both models are also equipped with a durable anode rod that further enhances corrosion resistance.

Safety is another critical characteristic of the (A)BCG38T500-8P and (A)BCG385T500-8N. They include safety features such as a temperature and pressure relief valve, ensuring that the system operates safely under various conditions. Additionally, these models often come with a 6-year limited warranty, providing peace of mind for homeowners.

Installation is straightforward, as these water heaters are designed to fit standard plumbing setups. They also offer a range of adjustable settings, allowing homeowners to customize their hot water experience according to their specific needs.

In summary, the American Water Heater (A)BCG38T500-8P and (A)BCG385T500-8N stand out for their ample capacity, energy-efficient operation, durable construction, and safety features. They represent a reliable choice for those seeking effective and long-lasting water heating solutions in their homes.