American Water Heater BCL3 85T275 6NOX Installation considerations, Rough In Dimensions

Page 8

Installation considerations

Rough In Dimensions

I

TOP OUTLET

1 1/2" NPT

11/2"

NPT

A C

D H

G

E

B

J

FRONT VIEW

TOP INLET 1 1/2" NPT

F

K

M

L

TOP VIEW

BACK VIEW

Figure 6.

Table 1. Rough-In-Dimensions

Model Dim.

BCL3 95T199 6NOX

(A)BCL3 85T275 6NOX

(A)BCL3 85T390 6NOX

inches

cm

inches

cm

inches

cm

 

A

76

193.0

76

193.0

76

193.0

B

11 3/4

29.8

11 3/4

29.8

11 3/4

29.8

C

78 1/4

198.8

78 1/4

198.8

78 1/4

198.8

D

65 3/4

167.0

65 3/4

167.0

65 3/4

167.0

E

25 3/4

65.4

25 3/4

65.4

25 3/4

65.4

F

21

53.3

21

53.3

21

53.3

G

3/4 NPT

 

3/4 NPT

 

3/4 NPT

 

H

66 1/4

168.3

66 1/4

168.3

66 1/4

168.3

I

6

15.2

6

15.2

6

15.2

J

27 3/4

70.5

27 3/4

70.5

27 3/4

70.5

K

1 1/2 NPT

 

1 1/2 NPT

 

1 1/2 NPT

 

L

1 1/2 NPT

 

1 1/2 NPT

 

1 1/2 NPT

 

M

41

104

41

104

41

104

Approx. Shipping Weight STD

790 lbs.

358 Kg.

850 lbs.

386 Kg.

850 lbs.

386 Kg.

Approx. Shipping Weight ASME

-

-

900 lbs.

408 Kg.

900 lbs.

408 Kg.

Table 2. Recovery Capacities, based on 82% efficiency

 

Input

Input

U.S.

 

 

 

 

 

U. S. Gallons/Hr. and Liters/Hr. at TEMPERATURE RISE INDICATED

 

 

 

 

BTUH

KW

Gal.

Liters

Eff. %

Deg. F

36

40

50

54

60

70

72

80

90

100

108

110

120

126

130

140

 

Deg. C

20

22

28

30

33

39

40

44

50

56

60

61

67

70

72

78

 

 

 

 

 

 

BCL3 95T199 6NOX

199000

 

93

 

82

GPH

545

491

393

364

327

280

273

245

218

196

182

178

164

156

151

140

 

58

 

352

 

LPH

2064

1858

1486

1376

1239

1062

1032

929

826

743

688

676

619

590

572

531

 

 

 

 

(A)BCL3 85T275 6NOX

275000

 

85

 

82

GPH

754

678

543

502

452

388

377

339

301

271

251

247

226

215

209

194

 

81

 

322

 

LPH

2853

2567

2054

1902

1712

1467

1426

1284

1141

1027

951

934

856

815

790

734

 

 

 

 

(A)BCL3 85T390 6NOX

390000

 

85

 

82

GPH

1069

962

769

712

641

550

534

481

427

385

356

350

321

305

296

275

 

114

 

322

 

LPH

4046

3641

2913

2697

2427

2081

2023

1820

1618

1456

1349

1324

1214

1156

1120

1040

 

 

 

 

Table 3. Gas and Electrical Characteristics

Model

Gas Type

Gas Supply Pressure

Volts / Hz

Amperes

Minimum

Maximum

 

 

 

 

All Models

Natural

3.5" W.C. (0.87 kPa)

14" W.C. (3.48 kPa)

120/60

<5

8

Image 8
Contents Commercial gas water heaters Table Of Contents Safe Installation, Use and Service ApprovalsGeneral Safety Information Fire and Explosion HazardHydrogen Gas Flammable PrecautionsGrounding Instructions Qualified Installer or Service Agency IntroductionAbbreviations Used QualificationsFeatures and Components Eliminator self-cleaning systemBlower/Burner Assembly High Limit Switch ControlsInstallation considerations Rough In DimensionsRough-In-Dimensions Recovery Capacities, based on 82% efficiencyLocating the Water Heater ClearancesNSF Leg Kit Insulation BlanketHard Water Circulation PumpsHigh Altitude Installations Breathing Hazard Carbon Monoxide GasInstallation Requirements Temperature-Pressure Relief Valve Dishwashing MachinesClosed Water Systems Thermal ExpansionValve Discharge Pipe Requirements Combustible Material StorageContaminated Air Air Requirements Unconfined SpaceConfined Space VentingMultiple Heater Manifold Outdoor Air Through One Opening Fresh Air Openings for Confined SpacesOutdoor Air Through Two Openings Outdoor Air Through Two Horizontal DuctsOutdoor Air Through Two Vertical Ducts Air From Other Indoor SpacesType B GAS Vent Multiple Gas Fired Tank-Type HeatersModel ABCL3 85T275 6NOX Valve Discharge Pipe Water heater installationWater Line Connections Installation Diagrams Top Inlet/Outlet Usage Tube Inlet InstallationHeater Wiring Gas Line Leak Testing Gas PipingPurging Gas Meter Size Natural Gases OnlyInitial Start Up Start upPrior to Start Up Water Temperature Adjustment Multiple Appliance InstallationsChecking Venting Checking the InputSequence of Operation Lighting & Operating LabelSequence of Operation Flow Chart YESMaintenance Temperature-Pressure Relief Valve TestVenting System Intake Air ScreenDraining and Flushing Deliming SolventsTo Drain the Water Heater Storage Tank To Flush the Water Heater Storage TankTank Cleanout Procedure Deliming Using Flo-Jug MethodElectrical Servicing System DiagnosticsIgnition Control System High Water Temperature Shut OFF System For Your InformationStart Up Conditions Operational ConditionsComplaint Cause Remedy User TroubleshootingQualified Service Agency Diagrams Water PipingTemperature & Pressure Temperature & Pressure Relief Valve Circulating Pump Multi Flue 2 Units Multi Flue 2 Units with Vertical Storage Tank Multi Flue 2 Units with Vertical Storage Tank Return from Multi Flue 2 Units TWO Temperature Multi Flue 2 Units with Booster TWO Temperature MULTI-FLUE 3 Units MULTI-FLUE 3 Units with Vertical Storage Tank MULTI-FLUE 3 Units with Horizontal Storage Tank Multi Flue Flue 4 Units MULTI-FLUE 4 Units with Vertical Storage Tank MULTI-FLUE 4 Units with Horizontal Storage Tank Model Dimension a Page Service and Repair Expenses Claim ProcedureALL Other Parts Conditions and Exceptions

BCL3 95T199 6NOX, BCL3 85T390 6NOX, BCL3 85T275 6NOX specifications

American Water Heater Company has been a leader in the production of high-quality water heaters for residential and commercial use. Among their acclaimed collection are three notable models: the BCL3 85T275 6NOX, BCL3 85T390 6NOX, and BCL3 95T199 6NOX. Each of these models is meticulously designed, providing efficient heating solutions while prioritizing safety and environmental responsibility.

The BCL3 85T275 6NOX is an advanced model that offers a remarkable 275,000 BTU output, making it suitable for a variety of applications, from single-family homes to larger commercial settings. This unit features a powerful water heating capacity and is equipped with a robust heat exchanger that maximizes thermal efficiency. One of its key technological innovations is the low nitrogen oxide (NOX) emissions system, which significantly reduces harmful emissions, thereby complying with stringent environmental standards.

Similarly, the BCL3 85T390 6NOX enhances performance with a higher BTU output of 390,000. This capacity allows it to effectively serve larger facilities with higher demand for hot water. The technology behind this model includes an automatic flue damper that optimizes energy use by adjusting the airflow, resulting in improved combustion efficiency. Additionally, its durable construction ensures long service life, catering to the needs of both residential users and commercial operations.

The BCL3 95T199 6NOX, with its 199,000 BTU capacity, combines efficiency with versatility. This unit is designed for a wide range of water heating needs, providing an excellent option for both medium-sized homes and smaller commercial setups. Its unique design incorporates advanced insulation materials that help retain heat longer, thereby enhancing overall efficiency. Like its counterparts, this model is equipped with advanced NOX reduction technology, which makes it an environmentally friendly choice.

All three models share a common theme of reliability and efficiency. Their advanced control systems enable precise temperature management, allowing users to set their desired hot water temperatures with ease. Furthermore, each unit is designed with safety features such as a high-temperature limit switch and electronic ignition, ensuring safe operation.

In conclusion, the American Water Heater BCL3 series — featuring the BCL3 85T275 6NOX, BCL3 85T390 6NOX, and BCL3 95T199 6NOX — showcases the company's commitment to innovation, quality, and environmental stewardship. These models not only meet the demanding needs of consumers but also contribute to a more sustainable future with their low emissions and efficient systems. Whether for residential or commercial use, they are designed to deliver reliable performance year after year.