TEMPERATURE REGULATION

DANGER

THIS WATER HEATER IS EQUIPPED WITH AN ADJUSTABLE THERMOSTAT TO CONTROL WATER TEMPERATURE. HOT WATER TEMPERATURES REQUIRED FOR AUTOMATIC DISHWASHING AND LAUNDRY USE CAN CAUSE PAINFUL SCALDING WITH POSSIBLE SERIOUS AND PERMANENT INJURY. THE TEMPERATURE AT WHICH INJURY OCCURS VARIES WITH THE PERSON’S AGE AND THE TIME OF THE EXPOSURE. THE SLOWER RESPONSE TIME OF CHILDREN, AGED OR DISABLED PERSONS INCREASES THE HAZARDS TO THEM. NEVER ALLOW SMALL CHILDREN TO USE A HOT WATER TAP, OR TO DRAW THEIR OWN BATH WATER. NEVER LEAVE A CHILD OR DISABLED PERSON UNATTENDED IN A BATHTUB OR SHOWER.

THE WATER HEATER SHOULD BE LOCATED IN AN AREA WHERE THE GENERAL PUBLIC DOES NOT HAVE ACCESS. IF A SUITABLE AREA IS NOT AVAILABLE, A COVER SHOULD BE INSTALLED OVER THE THERMOSTAT TO PREVENT TAMPERING.Suitable covers are available from the manufacturer, authorized service agencies or distributors. When ordering parts be sure to have the complete water heater Model Number, Serial Number and Series Number available. This information can be found on the rating label affixed to the water heater.

It is recommended that lower water temperatures be used to avoid the risk of scalding. It is further recommended, in all cases, that the water temperature setting be set for the lowest temperature that satisfies your hot water needs. This will also provide the most energy efficient operation of the water heater. The water temperature adjustment was factory set at the lowest temperature. Pressing the "COOLER" button decreases temperature and pressing the "HOTTER" button increases the temperature.

 

 

Time to Produce

 

Display

2nd & 3rd Degree

Temperature Setting

B C D E F

Burns on Adult Skin

 

 

 

SETTING THE WATER HEATER TEMPERATURE AT 120°F (49°C)

(APPROX. "" MARK ON FACE OF THE TEMPERATURE ADJUSTING DIAL) WILL REDUCE THE RISK OF SCALDS. Some States or Provinces require settings at specific lower temperatures.

Figure 6 shows the approximate water temperatures produced at various thermostat settings. Short repeated heating cycles caused by small hot water uses can cause temperatures at the point of use to exceed the thermostat setting by up to 20°F (11°C). If you experience this type of use you should consider using lower temperature settings to reduce scald hazards.

Valves for reducing point of use temperature by mixing cold and hot water are available. Also available are inexpensive devices that attach to faucets to limit hot water temperatures. Contact a licensed plumber or the local plumbing authority.

To avoid any unintentional changes in water temperature settings, the control has a tamper resistant feature for changing the temperature setting. To change the temperature setting follow these instructions:

1."Wake Up" the temperature indicators by holding down both the "COOLER" and "HOTTER" temperature adjustment buttons at the same time for one second (see Figure 6). One or two of the temperature indicators will light up. These indicators will only remain on for 30 seconds if no further buttons are pressed. After 30 seconds the control will go back to "Sleep" mode.

2.Release both of the temperature adjustment buttons.

A.To decrease the temperature press and release the "COOLER" button until desired setting is reached.

B.To increase the temperature press and release the "HOTTER" button until the desired setting is reached.

NOTE: Holding down the button will not continue to lower or raise the temperature setting. The button must be pressed and released for each temperature change desired.

SHOULD OVERHEATING OCCUR OR THE GAS SUPPLY FAIL TO SHUT OFF, TURN OFF THE MAIN MANUAL GAS SHUTOFF VALVE TO THE APPLIANCE. SEE FIGURE 1 (G).

CHECKING VENTING

The following steps shall be followed with each appliance connected to the venting system placed in operation, while any other appliances connected to the venting system are not in operation.

1.

Seal any unused openings in the venting system.

2.

Inspect the venting system for proper size and horizontal pitch, as

 

required in the National Fuel Gas Code, ANSI Z223.1/NFPA 54

 

or the CAN/CSA-B149.1 Installation codes and these instructions.

 

Determine that there is no blockage or restriction, leakage, corrosion

 

and other deficiencies which could cause an unsafe condition.

3.

So far as is practical, close all building doors and windows and all

 

doors between the space in which the water heater(s) connected

 

to the venting system are located and other spaces of the building.

 

Turn on all appliances not connected to the venting system. Turn

F= approx. 180°F (82°C) E = approx. 170°F (77°C) D = approx. 160°F (71°C) C = approx. 150°F (65°C) B = approx. 140°F (60°C) B = approx. 130°F (54°C)

= approx. 120°F (49°C)

Nearly Instantaneous Nearly Instantaneous About 1/2 Second About 1 1/2 Seconds Less than 5 Seconds More than 30 Seconds More than 5 Minutes

 

on all exhaust fans, such as range hoods and bathroom exhausts,

 

so they shall operate at maximum speed. Close fireplace dampers.

4.

Follow the lighting instruction. Place the water heater being

 

inspected in operation. Adjust thermostat so appliance shall operate

 

continuously.

5.

Test for vent system leakage after 5 minutes of main burner operation.

FIGURE 6.

11

Image 11
Contents Notify Owner to Keep for Future Reference Place These Instructions Adjacent to HeaterTOP View DimensionsRecovery Ratings Input Rate GAS and Electrical CharacteristicsTable of Contents Installation Instructions Unconfined Space ClearancesHard Water AIR RequirementsVent Connection VentingSystem Connections Combination Water Potable Heating Space HeatingRelief Valve GAS PipingWiring Diagram and Schematic Heater WiringGAS Meter Size Natural Gases only PurgingGAS Pressure Regulator To Operate the HeaterWhat to do if YOU Smell GAS For Your Safety Read Before OperatingChecking Venting Temperature RegulationChecking GAS Input Service InformationHigh Temperature Limit Switch ECO Main Burner and IgniterPreventive Maintenance FLO-JUG Method of Deliming Tank Cleanout ProcedureAnode ChecklistCondensation Water Heating Cycle TroubleshootingService and Repair GAS and Electric Power are ON,OFF/ON Switch is onLeaking T&P Valve Not Enough or no HOT WaterCondensation Water LeaksTrouble Shooting Troubleshooting GuidelinesD E F Black resistor wire between pins 3 & 4 with an ohm meterUnplug the ignitor assembly plug from the control. Check Page Page Conditions and Exceptions Service and Repair ExpensesClaim Procedure ALL Other Parts

BBCN375T754NV, Commercial Ultra Low NOx Gas water Heater specifications

The American Water Heater BBCN375T754NV is a standout in the realm of commercial water heating solutions, specifically designed to meet the demands of businesses requiring high efficiency and reliability. This ultra-low NOx gas water heater is engineered to reduce nitrogen oxide emissions, adhering to strict environmental regulations, which makes it an ideal choice for those conscious of their ecological footprint.

One of the main features of the BBCN375T754NV is its impressive capacity of 75 gallons, making it suitable for various commercial applications, including restaurants, hotels, and manufacturing facilities. This model is built to provide a consistent and rapid supply of hot water, ensuring that users have access to the hot water they need without interruption.

The heater is equipped with a powerful gas burner system, providing an input of 375,000 BTUs per hour, which guarantees robust performance even during peak demand times. This high input rate allows for quick recovery and reduces waiting times for hot water delivery, an essential factor in maintaining operational efficiency.

In terms of technology, the BBCN375T754NV incorporates advanced combustion management systems that optimize gas consumption and efficiency. This ensures that the heater operates at maximum capacity while minimizing energy waste. Additionally, the unit features a robust insulation system designed to reduce heat loss, further contributing to its energy-efficient performance.

Another important characteristic of this water heater is its durable construction. Made from high-quality materials, including a glass-lined tank for corrosion resistance, the BBCN375T754NV is built to withstand the rigors of a commercial environment. The unit comes with a built-in anode rod to enhance longevity and minimize maintenance needs.

Furthermore, the heater includes an easy-to-navigate digital display that simplifies temperature adjustments and monitoring. This feature enables operators to easily manage the system settings, ensuring optimal performance and safety.

To sum up, the American Water Heater BBCN375T754NV is designed for those who need an efficient, reliable, and environmentally friendly solution to their commercial hot water requirements. With its high capacity, advanced technologies, and durable design, it stands as a robust option for businesses looking to enhance their water heating systems while adhering to environmental standards.