TROUBLESHOOTING GUIDELINES

WATER HEATER CONTROL

TROUBLE SHOOTING

Please check guidelines below. For your safety, water heater service should be performed only by a qualified service technician.

Read the GENERAL SAFETY INFORMATION section first.

INTELLI-VENT TROUBLESHOOTING CHART - USER CONTROL

 

#

LED STATUS

PROBLEM

 

SOLUTION

 

15

B C D E F

The self-diagnostic test determined resistance

1.

Turn off power to the water heater.

 

 

of the black resistor wire on ignitor assembly

2.

Unplug the ignitor assembly plug from the control. Check

 

 

 

plug is not within tolerance.

 

 

 

 

the resistance of the black resistor wire between pins

 

 

 

 

 

 

 

 

 

 

3 & 4 with an ohm meter. 2.1 If the reading taken is more

 

 

 

 

 

than 100,000 (50,000 for data code before 0616; 70,000

 

 

 

 

 

for data code 0617 through 0709) ohms replace the ignitor

 

 

 

 

 

assembly. 2.2 If the reading taken is less than 100,000

 

 

 

 

 

(50,000 for data code before 0616; 70,000 for data code

 

 

 

 

 

0617 through 0709) ohms replace Intelli-Vent™ control.

 

16

B C D E F

Air pressure switch circuit is opening

1.

Ensure air pressure switch hose is not kinked or clogged;

 

 

repeatedly during one heating cycle. May be

 

ensure the blower housing is clear of any condensation.

 

 

 

caused by air pressure switch and/or the vent

2.

Check vent temperature limit switch - if it is determined

 

 

 

temperature limit switch (these two switches

 

 

 

are wired together in a “series” circuit).

 

that the vent temperature limit switch is opening its

 

 

 

 

 

contacts at normal operating temperatures during heating

 

 

 

 

 

cycle - replace the vent temperature limit switch.

 

 

 

 

3.

Ensure water heater is not over-firing. 3.1 Check burner

 

 

 

 

 

orifice size and ensure the correct orifice is installed;

 

 

 

 

 

replace as necessary. 3.2 Check manifold gas pressure

 

 

 

 

 

and ensure it is within 0.3” W.C. (75 Pa) of listed rating on

 

 

 

 

 

Intelli-Vent™ control valve. Manifold gas pressure is

 

 

 

 

 

non-adjustable, if manifold gas pressure is off by more

 

 

 

 

 

than 0.3” W.C. (75 Pa), replace the Intelli-Vent™ control.

 

 

 

 

4.

Ensure condensate lines are not obstructed. Check and

 

 

 

 

 

clear all condensate lines including the floor condensate

 

 

 

 

 

drain line.

 

 

 

 

 

 

 

 

 

 

 

 

20

Image 20
Contents Place These Instructions Adjacent to Heater Notify Owner to Keep for Future ReferenceDimensions Recovery Ratings Input RateGAS and Electrical Characteristics TOP ViewTable of Contents Installation Instructions Clearances Hard WaterAIR Requirements Unconfined SpaceVenting Vent ConnectionCombination Water Potable Heating Space Heating Relief ValveGAS Piping System ConnectionsHeater Wiring Wiring Diagram and SchematicPurging GAS Pressure RegulatorTo Operate the Heater GAS Meter Size Natural Gases onlyFor Your Safety Read Before Operating What to do if YOU Smell GASTemperature Regulation Checking VentingService Information High Temperature Limit Switch ECOMain Burner and Igniter Checking GAS InputPreventive Maintenance Tank Cleanout Procedure FLO-JUG Method of DelimingAnode ChecklistCondensation Troubleshooting Service and RepairGAS and Electric Power are ON,OFF/ON Switch is on Water Heating CycleNot Enough or no HOT Water CondensationWater Leaks Leaking T&P ValveTroubleshooting Guidelines Trouble ShootingBlack resistor wire between pins 3 & 4 with an ohm meter D E FUnplug the ignitor assembly plug from the control. Check Page Page Service and Repair Expenses Claim ProcedureALL Other Parts Conditions and Exceptions

BBCN375T754NV, Commercial Ultra Low NOx Gas water Heater specifications

The American Water Heater BBCN375T754NV is a standout in the realm of commercial water heating solutions, specifically designed to meet the demands of businesses requiring high efficiency and reliability. This ultra-low NOx gas water heater is engineered to reduce nitrogen oxide emissions, adhering to strict environmental regulations, which makes it an ideal choice for those conscious of their ecological footprint.

One of the main features of the BBCN375T754NV is its impressive capacity of 75 gallons, making it suitable for various commercial applications, including restaurants, hotels, and manufacturing facilities. This model is built to provide a consistent and rapid supply of hot water, ensuring that users have access to the hot water they need without interruption.

The heater is equipped with a powerful gas burner system, providing an input of 375,000 BTUs per hour, which guarantees robust performance even during peak demand times. This high input rate allows for quick recovery and reduces waiting times for hot water delivery, an essential factor in maintaining operational efficiency.

In terms of technology, the BBCN375T754NV incorporates advanced combustion management systems that optimize gas consumption and efficiency. This ensures that the heater operates at maximum capacity while minimizing energy waste. Additionally, the unit features a robust insulation system designed to reduce heat loss, further contributing to its energy-efficient performance.

Another important characteristic of this water heater is its durable construction. Made from high-quality materials, including a glass-lined tank for corrosion resistance, the BBCN375T754NV is built to withstand the rigors of a commercial environment. The unit comes with a built-in anode rod to enhance longevity and minimize maintenance needs.

Furthermore, the heater includes an easy-to-navigate digital display that simplifies temperature adjustments and monitoring. This feature enables operators to easily manage the system settings, ensuring optimal performance and safety.

To sum up, the American Water Heater BBCN375T754NV is designed for those who need an efficient, reliable, and environmentally friendly solution to their commercial hot water requirements. With its high capacity, advanced technologies, and durable design, it stands as a robust option for businesses looking to enhance their water heating systems while adhering to environmental standards.