TANK CLEANOUT PROCEDURE

The following practices will ensure longer life and enable the unit to operate at its designed efficiency:

1.Once a month the heater should be flushed. Open the drain valve and allow two gallons of water to drain from the heater. Inlet water valve should remain open to maintain pressure in tank.

2.A cleanout opening is provided for periodic cleaning of the tank. Gas must be shut off and heater drained before opening cleanout.

To clean heater through cleanout opening, proceed as follows:

1.Drain heater.

2.Remove outer cover plate from lower side of heater jacket.

3.Remove six (6) hex head screws securing tank cleanout plate and remove plate.

4.Remove lime, scale, or sediment using care not to damage the glass lining.

5.Inspect cleanout plate gasket, if new gasket is required.

6.Install cleanout plate. Be sure to draw plate up tight by tightening screws securely.

7.Replace outer jacket cover plate.

In some water areas the sediment might not be removed by this method and may result in the water heater making rumbling or boiling noises. To dissolve and remove these more stubborn mineral deposits, UN•LIME Professional Delimer should be used.

2.With the Flo-Jug upright:

Take off cap, remove cover under opening and install 3/4" x 4" pipe nipple.

Drill or punch a 3/16" vent hole in handle. A stainless steel screw is included with the Flo-Jug kit. This screw is to be installed in the vent hole when Flo-Jug is not in use.

Remove drain valve from heater and insert a 3/4" x 4" nipple.

Connect and clamp 1" I.D. x 3" hose to Flo-Jug and heater nipple.

3.Lift the Flo-Jug to the POUR POSITION and permit the UN•LIME to flow into the heater as rapidly as possible.

Be sure to keep the vent just above the liquid level.

4.Place the Flo-Jug in the DELIME POSITION.

It may be necessary to place the empty jug on its carton to trap the solution in the heater.

Allow the UN•LIME to attack the water scale for 5 minutes.

5.Lower the Flo-Jug to the DRAIN POSITION and allow the UN•LIME to flow out of the heater as rapidly as possible.

Observe the vent holes and elevate the jug slightly if there is a possibility of spillage.

Deliming activity is indicated by foaming on the surface of the solution.

6.Continue the deliming process:

FIGURE 9

FLO-JUG METHOD OF DELIMING

The Flo-Jug is the standard 5 gallon container for UN•LIME -or- it is available as a deliming kit with hose and fittings. Contact your dealer or distributor.

Figure 9 illustrates most of the following steps.

1.The heater should be prepared for deliming as described in the “Why? When and How” booklet. The relief valve may also be delimed at this time.

Raise jug to POUR POSITION. Allow solution to flow into heater.

Place jug in DELIME POSITION for 5 minutes. Solution is at work in heater.

Lower jug to DRAIN POSITION and allow solution to flow out.

Observe foaming.

7.After one hour, or earlier if the deliming activity (foaming) stops, inspect the tank interior.

Drain the UN•LIME back into jug, DRAIN POSITION, and then stand jug in DELIME POSITION.

Remove the clamp, hose and the pipe nipple from heater drain opening.

Observe interior through opening - a small flashlight may be used effectively.

If the interior still shows water scale, the deliming process should be continued.

To check UN•LIME for continued use or reuse, place some lime scale or white chalk into a glass with a small amount of solution. If the material is vigorously dissolved by the solution, the UN•LIME can be reused. If not, the UN•LIME has been weakened and should be replaced.

8.When deliming has been completed, the heater should be flushed for 3 to 5 minutes with fresh water.

Remove the deliming equipment, install the drain valve, open the

14

Image 14
Contents Place These Instructions Adjacent to Heater Notify Owner to Keep for Future ReferenceGAS and Electrical Characteristics DimensionsRecovery Ratings Input Rate TOP ViewTable of Contents Installation Instructions AIR Requirements ClearancesHard Water Unconfined SpaceVenting Vent ConnectionGAS Piping Combination Water Potable Heating Space HeatingRelief Valve System ConnectionsHeater Wiring Wiring Diagram and SchematicTo Operate the Heater PurgingGAS Pressure Regulator GAS Meter Size Natural Gases onlyFor Your Safety Read Before Operating What to do if YOU Smell GASTemperature Regulation Checking VentingMain Burner and Igniter Service InformationHigh Temperature Limit Switch ECO Checking GAS InputPreventive Maintenance Tank Cleanout Procedure FLO-JUG Method of DelimingAnode ChecklistCondensation GAS and Electric Power are ON,OFF/ON Switch is on TroubleshootingService and Repair Water Heating CycleWater Leaks Not Enough or no HOT WaterCondensation Leaking T&P ValveTroubleshooting Guidelines Trouble ShootingBlack resistor wire between pins 3 & 4 with an ohm meter D E FUnplug the ignitor assembly plug from the control. Check Page Page ALL Other Parts Service and Repair ExpensesClaim Procedure Conditions and Exceptions

BBCN375T754NV, Commercial Ultra Low NOx Gas water Heater specifications

The American Water Heater BBCN375T754NV is a standout in the realm of commercial water heating solutions, specifically designed to meet the demands of businesses requiring high efficiency and reliability. This ultra-low NOx gas water heater is engineered to reduce nitrogen oxide emissions, adhering to strict environmental regulations, which makes it an ideal choice for those conscious of their ecological footprint.

One of the main features of the BBCN375T754NV is its impressive capacity of 75 gallons, making it suitable for various commercial applications, including restaurants, hotels, and manufacturing facilities. This model is built to provide a consistent and rapid supply of hot water, ensuring that users have access to the hot water they need without interruption.

The heater is equipped with a powerful gas burner system, providing an input of 375,000 BTUs per hour, which guarantees robust performance even during peak demand times. This high input rate allows for quick recovery and reduces waiting times for hot water delivery, an essential factor in maintaining operational efficiency.

In terms of technology, the BBCN375T754NV incorporates advanced combustion management systems that optimize gas consumption and efficiency. This ensures that the heater operates at maximum capacity while minimizing energy waste. Additionally, the unit features a robust insulation system designed to reduce heat loss, further contributing to its energy-efficient performance.

Another important characteristic of this water heater is its durable construction. Made from high-quality materials, including a glass-lined tank for corrosion resistance, the BBCN375T754NV is built to withstand the rigors of a commercial environment. The unit comes with a built-in anode rod to enhance longevity and minimize maintenance needs.

Furthermore, the heater includes an easy-to-navigate digital display that simplifies temperature adjustments and monitoring. This feature enables operators to easily manage the system settings, ensuring optimal performance and safety.

To sum up, the American Water Heater BBCN375T754NV is designed for those who need an efficient, reliable, and environmentally friendly solution to their commercial hot water requirements. With its high capacity, advanced technologies, and durable design, it stands as a robust option for businesses looking to enhance their water heating systems while adhering to environmental standards.