Page 10

INSTALLATION REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS

For all side wall terminated, horizontally vented power vent, gas fueled water heaters installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:

INSTALLATION OF CARBON MONOXIDE DETECTORS At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the sidewall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors.

In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements provided that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

APPROVED CARBON MONOXIDE DETECTORS Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and CSA certified.

SIGNAGE A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT

DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS.”

INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a) 1 through 4.

EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:

1.The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and

2.Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building, or structure used in whole or in part for residential purposes.

MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

1.Detailed instructions for the installation of the venting system design or the venting system components; and

2.A complete parts list for the venting system design or venting system.

MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies “special venting systems,” the following requirements shall be satisfied by the manufacturer:

1.The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and

2.The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include

a parts list and detailed installation instructions.

A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

10

www.americanwaterheater.com

Image 10
Contents Power Vent GAS Models AN Odorant is Added to the GAS Used By this Water HeaterTable of Contents Safe INSTALLATION, USE and Service Important DefinitionsGeneral Safety Can be triggered at any time Preparing for the Installation IntroductionPage GET to Know Your Water Heater GAS Models Replacement Parts and Deliming ProductsOperation Installation Considerations Rough in DimensionsDirectly BELOW. Keep Clear of ALL Obstructions Water Potable Heating All models are considered Water Piping Mixing Valve UsageSuggested Piping Arrangement For TOP Connections Hotter Water can ScaldFacts to Consider about Location Handle Installation Earthquake Zones Page Appliances in Unconfined Spaces Combustion AIR and VentilationAppliances in Confined Spaces ALL AIR from Outdoors See Figures 12, 13 Closed Water Systems Chemical Vapor CorrosionWater Piping Thermal ExpansionTEMPERATURE-PRESSURE Relief Valve Hard WaterValve and Pipe Insulation if supplied GAS Piping FLOODING/FREEZING High Altitude InstallationsGAS Line Purging Filling the Water HeaterVent Pipe Termination If using 2 inch vent pipePlanning the Vent System If using 3 inch vent pipe Condensate Installation of Vent SystemVent Terminal INSTALLATION, Sidewall Masonry Side WallsInstallation Sequence Sequence of InstallationsVent terminals supplied with heater must be used Installation of Vent SYSTEM, Sidewall Installation of Vertical Vent SystemInitial Preparation Vent Pipe PreparationSelection of Materials Step a Recommended BRUSH* Size for Primer Cement ApplicationsStep B Step F Power VentStep E Step G Connection to Vent PipeVent Hoods MAY be Extremely HOT During Operation Filling the Water Heater Electrical ConnectionsCalibration Operating Instructions Display PanelPage MCU For Your Safety Read Before Lighting Lighting InstructionsHeat Cycle Definitions State Description Temperature Regulation Unique Hybrid Features Temperature ProbesPage Temperature Regulation Start UP Conditions Constant Output Temperature ControlOperational Conditions Venting System Inspection MaintenanceHousekeeping Burner Operation and InspectionCleaning the Inlet Water Filter Anode ROD ReplacementTEMPERATURE-PRESSURE Relief Valve Operation MotorsCleaning the Heat Engine Flushing the Heat Exchanger Lime BUILD- UPFault Indication and Error Codes Draining the TankRemarks Diagnostic DisplayCode Display Example Format Fault Lockout Code Description Cause Remedy Type Displayed Fault Lockout Code Description Cause Remedy Type Displayed Fault Lockout Code Description Cause Remedy Type Displayed Troubleshooting HOT Water Turns Cold When the TAP is OpenedThere is no HOT Water or Stays ColdService Leakage CheckpointsParts Identification Item # Description AB C DEF NIP/DIP/TBO/HT Replacement Parts DescriptionKIT # Page Page

316888-004 specifications

The American Water Heater 316888-004 is a reliable and efficient choice for homeowners seeking a dependable and effective water heating solution. Designed with a focus on performance and convenience, this water heater provides an impressive array of features that meet the demands of modern living.

One of the standout characteristics of the 316888-004 is its efficient heating technology. The unit employs advanced heating elements that ensure rapid heating of water, reducing wait times for hot water availability. This feature is particularly beneficial for households with high hot water demands, such as those with multiple bathrooms or numerous appliances requiring hot water simultaneously. By delivering hot water quickly, this model enhances user satisfaction and improves overall household efficiency.

In terms of design, the American Water Heater 316888-004 boasts a compact structure, which makes it suitable for various installation environments, including tight spaces. Its durable construction is complemented by high-quality materials, ensuring longevity and reduced maintenance costs. This model is built to withstand the rigors of daily use, providing peace of mind to homeowners regarding its reliability and durability.

Safety is another important aspect of the 316888-004. The unit is equipped with multiple safety features, including a temperature and pressure relief valve, which helps prevent overheating and excessive pressure buildup. Additionally, it accommodates users' needs for energy efficiency, making it an environmentally friendly option. The device is designed to minimize energy consumption, which not only lowers utility bills but also contributes to reducing the household's overall carbon footprint.

Moreover, the 316888-004 is user-friendly, featuring a simple control interface that makes adjusting temperature settings easy. This accessibility allows users to customize their water heating experience according to their personal preferences.

In conclusion, the American Water Heater 316888-004 stands out as a top choice in its category. With its efficient heating technology, durable construction, focus on safety, energy efficiency, and user-friendly features, it meets the diverse needs of contemporary households. For anyone seeking a reliable, high-performance water heater, the 316888-004 is undoubtedly a smart investment, ensuring consistent hot water availability for years to come.