American Water Heater 316888-004 warranty Draining the Tank, Fault Indication and Error Codes

Page 46

Disconnect electrical power to the water heater.

Remove the pail of cleaning solution and replace it with a pail of clean water.

Rinse the cleaning solution from the water heater as follows:

Connect the electrical power to the water heater and run the heat engine.

Allow the clean water to flow through the heat engine for 5 minutes.

Disconnect electrical power to the water heater and circulating pump.

Disconnect the hoses from the heat engine.

Disconnect hoses and circulating pump, draining the cleaning solution into the pail.

Reconnect the original hoses to the tank.

Remove the in-line filter at the cold water inlet and clean out any residue. Assemble the filter back into the unit.

Open the shutoff valves on both the hot water and cold water lines.

Fill the tank with water.

Connect the electrical power to the water heater.

Restart water heater following lighting instructions.

DRAINING THE TANK

The water heater should be drained if being shut down during freezing temperatures. Also periodic draining and cleaning of sediment from the tank may be necessary.

1.Set the power switch to the “OFF” position.

2.OPEN a nearby hot water faucet and let the water run until it is no longer hot.

3.CLOSE the cold water inlet valve to the water heater.

4.Connect a hose to the drain valve and terminate to an adequate drain.

5.OPEN the water heater drain valve to allow for tank draining. NOTE: If the water heater is going to be shut down and drained for an extended period, the drain valve should be left open with hose connected allowing water to terminate to an adequate drain.

6.CLOSE the drain valve.

7.Follow instructions in the “Filling The Water Heater” section.

8.Follow the lighting instructions on the label or see “Lighting Instructions” in this manual to restart the water heater.

FAULT INDICATION AND ERROR CODES

A red fault LED (lighting a large red exclamation point) should be present on the display panel if a fault condition exists.

A history of the last 9 error codes along with the current error code is stored in memory and can be accessed via the maintenance mode. If the current error code is zero, “E00” shall be displayed (see Table 4).

46

www.americanwaterheater.com

Image 46
Contents Power Vent GAS Models AN Odorant is Added to the GAS Used By this Water HeaterTable of Contents Safe INSTALLATION, USE and Service Important DefinitionsGeneral Safety Can be triggered at any time Preparing for the Installation IntroductionPage GET to Know Your Water Heater GAS Models Replacement Parts and Deliming ProductsOperation Installation Considerations Rough in DimensionsDirectly BELOW. Keep Clear of ALL Obstructions Water Potable Heating All models are considered Water Piping Mixing Valve UsageSuggested Piping Arrangement For TOP Connections Hotter Water can ScaldFacts to Consider about Location Handle Installation Earthquake Zones Page Appliances in Unconfined Spaces Combustion AIR and VentilationAppliances in Confined Spaces ALL AIR from Outdoors See Figures 12, 13 Closed Water Systems Chemical Vapor CorrosionWater Piping Thermal ExpansionTEMPERATURE-PRESSURE Relief Valve Hard WaterValve and Pipe Insulation if supplied GAS Piping FLOODING/FREEZING High Altitude InstallationsGAS Line Purging Filling the Water HeaterVent Pipe Termination If using 2 inch vent pipePlanning the Vent System If using 3 inch vent pipe Condensate Installation of Vent SystemVent Terminal INSTALLATION, Sidewall Masonry Side WallsInstallation Sequence Sequence of InstallationsVent terminals supplied with heater must be used Installation of Vent SYSTEM, Sidewall Installation of Vertical Vent SystemInitial Preparation Vent Pipe PreparationSelection of Materials Step a Recommended BRUSH* Size for Primer Cement ApplicationsStep B Step F Power VentStep E Step G Connection to Vent PipeVent Hoods MAY be Extremely HOT During Operation Filling the Water Heater Electrical ConnectionsCalibration Operating Instructions Display PanelPage MCU For Your Safety Read Before Lighting Lighting InstructionsHeat Cycle Definitions State Description Temperature Regulation Unique Hybrid Features Temperature ProbesPage Temperature Regulation Start UP Conditions Constant Output Temperature ControlOperational Conditions Venting System Inspection MaintenanceHousekeeping Burner Operation and InspectionCleaning the Inlet Water Filter Anode ROD ReplacementTEMPERATURE-PRESSURE Relief Valve Operation MotorsCleaning the Heat Engine Flushing the Heat Exchanger Lime BUILD- UPFault Indication and Error Codes Draining the TankRemarks Diagnostic DisplayCode Display Example Format Fault Lockout Code Description Cause Remedy Type Displayed Fault Lockout Code Description Cause Remedy Type Displayed Fault Lockout Code Description Cause Remedy Type Displayed Troubleshooting HOT Water Turns Cold When the TAP is OpenedThere is no HOT Water or Stays ColdService Leakage CheckpointsParts Identification Item # Description AB C DEF NIP/DIP/TBO/HT Replacement Parts DescriptionKIT # Page Page

316888-004 specifications

The American Water Heater 316888-004 is a reliable and efficient choice for homeowners seeking a dependable and effective water heating solution. Designed with a focus on performance and convenience, this water heater provides an impressive array of features that meet the demands of modern living.

One of the standout characteristics of the 316888-004 is its efficient heating technology. The unit employs advanced heating elements that ensure rapid heating of water, reducing wait times for hot water availability. This feature is particularly beneficial for households with high hot water demands, such as those with multiple bathrooms or numerous appliances requiring hot water simultaneously. By delivering hot water quickly, this model enhances user satisfaction and improves overall household efficiency.

In terms of design, the American Water Heater 316888-004 boasts a compact structure, which makes it suitable for various installation environments, including tight spaces. Its durable construction is complemented by high-quality materials, ensuring longevity and reduced maintenance costs. This model is built to withstand the rigors of daily use, providing peace of mind to homeowners regarding its reliability and durability.

Safety is another important aspect of the 316888-004. The unit is equipped with multiple safety features, including a temperature and pressure relief valve, which helps prevent overheating and excessive pressure buildup. Additionally, it accommodates users' needs for energy efficiency, making it an environmentally friendly option. The device is designed to minimize energy consumption, which not only lowers utility bills but also contributes to reducing the household's overall carbon footprint.

Moreover, the 316888-004 is user-friendly, featuring a simple control interface that makes adjusting temperature settings easy. This accessibility allows users to customize their water heating experience according to their personal preferences.

In conclusion, the American Water Heater 316888-004 stands out as a top choice in its category. With its efficient heating technology, durable construction, focus on safety, energy efficiency, and user-friendly features, it meets the diverse needs of contemporary households. For anyone seeking a reliable, high-performance water heater, the 316888-004 is undoubtedly a smart investment, ensuring consistent hot water availability for years to come.