American Water Heater 6510319 Troubleshooting Chart, Problem Possible Causes Corrective Action

Page 27

TROUBLESHOOTING CHART (continued)

PROBLEM

 

POSSIBLE CAUSE(S)

 

CORRECTIVE ACTION

SLOW HOT WATER RECOVERY

1.

Insufficient secondary air

1.

Provide ventilation to water heater. Check flue way,

 

2.

Flue clogged

2.

flue baffle, and burner

 

Clean flue, locate source and correct

 

3.

Low gas pressure

3.

Check with gas utility company

 

4.

Improper calibration

4.

Replace thermostat

 

5.

Thermostat set too low

5.

Turn temperature dial to desired setting

 

6.

Water heater too small

6.

Install adequate heater

 

7.

Wrong piping connections

7.

Correct piping-dip tube must be in cold inlet

 

8.

Wasted hot water

8.

Advise customer

DRIP FROM RELIEF VALVE

1.

Excessive water pressure

1.

Use a pressure reducing valve and relief valve

 

2.

Heater stacking

2.

Lower the thermostat setting

 

3.

Closed water system

3.

See “Closed System/Thermal Expansion”

THERMOSTAT FAILS TO SHUT

1.

Defective thermostat

1.

Replace thermostat

OFF

2.

Improper calibration

2.

Replace thermostat

COMBUSTION ODORS

1.

Insufficient secondary air

1.

Provide ventilation to water heater. Check flue

 

2.

Flue clogged

2.

way, flue baffle, and burner

 

Clean, locate source and correct

 

3.

Heater installed in a confined area

3.

Provide fresh air ventilation

SMOKING AND CARBON

1.

Insufficient secondary air

1.

Provide ventilation to water heater. Check flue way,

FORMATION (SOOTING)

2.

Low gas pressure

2.

flue baffle, burner

 

Check with gas utility company

 

3.

Flue clogged

3.

Clean, locate source and correct

 

4.

Defective thermostat

4.

Replace thermostat

 

5.

Heater installed in a confined area

5.

Provide fresh air ventilation

 

6.

Burner flame yellow-lazy

6.

See “Burner Flame Yellow-Lazy”

CONDENSATION

1.

Temperature setting too low

1.

Increase the temperature setting

BURNER FLAME FLOATS AND

1.

Orifice too large

1.

Replace with correct orifice

LIFTS OFF PORTS

2.

High gas pressure

2.

Check with gas utility company

 

3.

Flue clogged

3.

Clean flue and burner-locate source and correct

 

4.

Cold drafts

4.

Locate source and correct

BURNER FLAME TOO HIGH

1.

Orifice too large

1.

Replace with correct orifice

FLAME BURNS AT ORIFICE

1.

Defective thermostat

1.

Replace thermostat

 

2.

Low gas pressure

2.

Check with gas utility company

PILOT FLAME

1.

Pilot line or orifice clogged

1.

Clean, locate source and correct

TOO SMALL

2.

Low gas pressure

2.

Check with gas utility company

27

Image 27
Contents Installation Instructions Use & Care Guide Table Of Contents Consumer Information Consumer ResponsibilitiesUnpacking the Water Heater Site Location Location RequirementsClearances and Accessibility Gas Pressure Gas Pressure TestingGas Supply Gas RequirementsNatural Gas Pipe Capacity Table Cu. Ft./Hr Combustion Air Supply and VentilationUnconfined Space Confined SpaceAll Air from Inside the Building Louvers and Grilles All Air from OutdoorsVent Pipe Size Drafthood InstallationVent Connectors Vent Pipe SystemVertical Exhaust Gas Vent Chimney ConnectionWater System Piping Piping InstallationClosed System/Thermal Expansion Temperature & Pressure Relief Valve Temperature and Pressure Relief ValveSolar Installation Special ApplicationsCombination Space Heating/Potable Water System Installation Checklist G. Bottled Propane Models Lighting InstructionsWater Temperature Regulation Checking the DraftBurn Hazard Do not touch vent Doing so can result in burns Operational Conditions Routine Preventative Maintenance Temperature and Pressure Relief ValveDraining and Flushing Natural Gas Burner Low Nox Replacement PartsRemoving the Manifold Assembly Removing the Burner from the Manifold AssemblyReplacing the Thermocouple External Inspection & Cleaning of the Flame-trapReplacing the Manifold Assembly Cleaning the Combustion Chamber and Flame-trapTesting the Igniter System Piezoelectric Igniter SystemRemoving and Replacing the Gas Control Valve/Thermostat Air Shutter adjustment for Flame Guard L.P.-30T only Flame Guard Safety System Operational Checklist Troubleshooting ChartProblem Possible Causes Corrective Action Troubleshooting ChartRepair Parts List Repair Parts IllustrationListed Parts Kits and Illustrations