American Water Heater 6510319 Repair Parts Illustration, Repair Parts List

Page 28

REPAIR PARTS ILLUSTRATION

Alternate anode

5

4

1

location for top

T & P

2

Anode location for side T & P

8

When ordering repair parts always give the following information:

1.Model, serial, and product number

2.Type of gas

3.Item number

4.Parts description

Repair Parts List

Item

Parts Description

No.

 

1

DRAFTHOOD

2

REDUCER RING - SOME MODELS

3

FLUE BAFFLE

4

HEAT TRAP (COLD) - SOME MODELS

5

HEAT TRAP (HOT) - SOME MODELS

6

COLD WATER DIP TUBE

7

ANODE ROD

8TEMPERATURE & PRESSURE RELIEF VALVE (LOCATED TOP OR SIDE)

9DRAIN VALVE

10 GAS VALVE/THERMOSTAT

11 PILOT ASSEMBLY/THERMOCOUPLE KIT

(Natural Gas)

12 PILOT ASSEMBLY/THERMOCOUPLE KIT

(L.P. Gas)

13 OUTER DOOR

14 BURNER (Natural Gas/Low Nox)

15 BURNER (L.P. Gas)

16 MANIFOLD DOOR ASSEMBLY (Natural Gas/Low Nox)

17 MANIFOLD DOOR ASSEMBLY (L.P. Gas)

18 TWO PIECE WIRE CONNECTOR

WITH RETAINER CLIP

19 MANIFOLD DOOR GASKET

20 VIEWPORT ASSEMBLY

21 THERMOCOUPLE ASSEMBLY (See page 22)

3

6

10

7

9

13

LEGEND

Special anode rod (see page 19)

Temperature and Pressure Relief Valve is required, but may not be factory installed

Unique: Flame Guard® Safety System parts

Pictured on next page.

28

Image 28
Contents Installation Instructions Use & Care Guide Table Of Contents Consumer Responsibilities Consumer InformationUnpacking the Water Heater Location Requirements Site LocationClearances and Accessibility Gas Pressure Testing Gas SupplyGas Requirements Gas PressureCombustion Air Supply and Ventilation Natural Gas Pipe Capacity Table Cu. Ft./HrConfined Space Unconfined SpaceAll Air from Inside the Building All Air from Outdoors Louvers and GrillesDrafthood Installation Vent ConnectorsVent Pipe System Vent Pipe SizeChimney Connection Vertical Exhaust Gas VentPiping Installation Water System PipingClosed System/Thermal Expansion Temperature and Pressure Relief Valve Temperature & Pressure Relief ValveSpecial Applications Solar InstallationCombination Space Heating/Potable Water System Installation Checklist Lighting Instructions G. Bottled Propane ModelsChecking the Draft Water Temperature RegulationBurn Hazard Do not touch vent Doing so can result in burns Operational Conditions Temperature and Pressure Relief Valve Routine Preventative MaintenanceDraining and Flushing Replacement Parts Removing the Manifold AssemblyRemoving the Burner from the Manifold Assembly Natural Gas Burner Low NoxExternal Inspection & Cleaning of the Flame-trap Replacing the ThermocoupleCleaning the Combustion Chamber and Flame-trap Replacing the Manifold AssemblyPiezoelectric Igniter System Testing the Igniter SystemRemoving and Replacing the Gas Control Valve/Thermostat Air Shutter adjustment for Flame Guard L.P.-30T only Troubleshooting Chart Flame Guard Safety System Operational ChecklistTroubleshooting Chart Problem Possible Causes Corrective ActionRepair Parts Illustration Repair Parts ListListed Parts Kits and Illustrations