EXTERNAL DAMAGE

Do not operate the water heater until it has been fully checked out by a qualified technician, if the water heater:

Has been exposed to fire or damage.

Displays evidence of sooting.

Produces steam or unusually hot water.

If the water heater has been flooded it must be replaced.

START UP CONDITIONS

NEVER OPERATE THE HEATER WITHOUT FIRST BEING CERTAIN IT IS FILLED WITH WATER AND A TEMPERATURE AND PRESSURE RELIEF VALVE IS INSTALLED IN THE RE- LIEF VALVE OPENING OF THE HEATER. DO NOT ATTEMPT TO OPERATE HEATER WITH COLD WATER INLET VALVE CLOSED.

CONDENSATE

Whenever the water heater is filled with cold water, some con- densate will form while the burner is on. A water heater may appear to be leaking when in fact the water is condensate. This usually happens when:

a.A new water heater is filled with cold water for the first time.

b.Burning gas produces water vapor in water heaters, par- ticularly high efficiency models where flue temperatures are lower.

c.Large amounts of hot water are used in a short time and the refill water in the tank is very cold.

Moisture from the products of combustion condense on the cooler tank surfaces and form drops of water which may fall onto the burner or other hot surfaces to produce a “sizzling” or “frying” noise.

Because of the suddenness and amount of water, condensate water may be diagnosed as a “tank leak”. After the water in the tank warms up (about 1-2 hours), the condition should disap- pear.

Do not assume the water heater is leaking until there has been enough time for the water in the tank to warm up.

An undersized water heater will cause more condensation. The water heater must be sized properly to meet the family’s de- mands for hot water including dishwashers, washing machines and shower heads.

Excessive condensate may be noticed during the winter and early spring months when incoming water temperatures are at their lowest.

Good venting is essential for a gas fired water heater to operate properly as well as to carry away products of combustion and water vapor.

SMOKE/ODOR

It is not uncommon to experience a small amount of smoke and odor during the initial start-up. This is due to burning off of oil from metal parts, and will disappear in a short while.

THERMAL EXPANSION

Water supply systems may, because of such events as high line pressure, frequent cut-offs, the effects of water hammer among others, have installed devices such as pressure reducing valves, check valves, back flow preventers, etc. to control these types of problems. When these devices are not equipped with an internal by-pass, and no other measures are taken, the devices cause the water system to be closed. As water is heated, it expands (thermal expansion) and closed systems do not allow for the expansion of heated water.

The water within the water tank expands as it is heated and in- creases the pressure of the water system. If the relieving point of the water heater’s temperature-pressure relief valve is reached, the valve will release the excess pressure. The temperature- pressure relief valve is not intended for the constant relief of thermal expansion. This is an unacceptable condition and must be corrected. It is recommended that any devices installed which could create a closed system have a by-pass and/or the system have an expansion tank or device to relieve the pressure built by thermal expansion in the water system. Expansion tanks are available for ordering through a local plumbing contractor. Contact the local water heater supplier or service agency for as- sistance in controlling these situations.

STRANGE SOUNDS

Possible noises due to expansion and contraction of some metal parts during periods of heat-up and cool-down do not necessarily represent harmful or dangerous conditions.

Condensation causes sizzling and popping within the burner area during heating and cooling periods and should be consid- ered normal. See “Condensate” in this section.

OPERATIONAL CONDITIONS

SMELLY WATER

In each water heater there is installed at least one anode rod (see parts section) for corrosion protection of the tank. Certain water conditions will cause a reaction between this rod and the water. The most common complaint associated with the anode rod is one of a “rotten egg smell” in the hot water. The smell is a result of four factors which must all be present for the odor to develop:

a.A concentration of sulfate in the supply water.

b.Little or no dissolved oxygen in the water.

c.A sulfate reducing bacteria which has accumulated within the water heater (this harmless bacteria is nontoxic to humans).

d.An excess of active hydrogen in the tank. This is caused by the corrosion protective action of the anode.

Smelly water may be eliminated or reduced in some water heater models by replacing the anode(s) with one of less active mate- rial, and then chlorinating the water heater tank and all water

21

Image 21
Contents Residential GAS Water Heaters Important Definitions Safe INSTALLATION, USE and ServiceGeneral Safety Introduction Table of ContentsKeep Clear of ALL Obstructions GET to Know Your Water Heater Replacement Parts Typical InstallationHotter Water can Scald Mixing Valve UsageFacts to Consider about the Location Locating the NEW Water HeaterInsulation Blankets Ventilation for Appliances Located in Confined SpacesVent Termination Required Ability Installing the NEW Water HeaterInspect Shipment GeneralValve and Pipe Insulation if Supplied TEMPERATURE-PRESSURE Relief ValveWater Potable Heating and Space Heating Closed Water SystemGAS Piping GAS Piping with Flexible Connector High Altitude Installations Sediment Traps Filling the Water HeaterVenting Vent Terminal Clearances Combustion AIR and VentilationVent Connections Locating Clearance Hole for VentHigh Rise Vent Arrangement Securing Vent Termination Assembly to the Exterior Wall Vent AssemblyStandard Vent Arrangement Uncompressing the Corrugated TubingMinimum Offset Vent ArrangementFigure D TOP KnobTemperature Regulation Temperature RegulationExternal Damage For Your InformationStart UP Conditions Operational ConditionsAIR in HOT Water Faucets Maintenance Venting System InspectionPilot and Main Burner Anode ROD Maintenance Temperature & Pressure Relief ValveDraining Cathodic Protection AnodeDrain Valve Washer Replacement Leakage Checkpoints ServiceProblem Possible Causes Correction Troubleshooting GuidelinesERY Slow HOT Water RecovDrip from Relief Valve Thermostat Fails toPage XCV, XCVL, XCVH, XVR Series Tank PartsXCVT, Xcvx Conditions and ExceptionsClaim Procedure Service and Labor ResponsibilityInstallation Information Limitation on Implied WarrantiesTennessee Waltz Parkway Ashland CITY, TN

GDV, GDVT specifications

A.O. Smith is a well-known name in the water heating industry, and its GDVT and GDV series of water heaters exemplify the company's commitment to quality, efficiency, and innovation. These models are designed to provide reliable hot water solutions for both residential and commercial needs, seamlessly integrating advanced technology and user-friendly features.

One of the main features of the GDVT and GDV series is their high energy efficiency ratings. These water heaters utilize advanced insulation and energy-saving technologies, allowing them to achieve impressive efficiency levels. The GDVT series, for instance, can achieve an Energy Factor (EF) rating of up to 0.96, making it an environmentally friendly choice that can significantly reduce energy bills. This high level of efficiency is a result of thoughtful engineering, including a highly insulated tank that minimizes heat loss.

Another standout characteristic of the GDVT and GDV series is their compact design. These models are built to fit into tight spaces, making them ideal for homes or businesses with limited installation areas. Despite their compact size, they maintain a large storage capacity, ensuring that users have access to consistent hot water. The GDVT series is particularly known for its vertical design, which allows for easy installation in smaller utility rooms or closets.

The GDV models feature a robust digital display that provides real-time information about the water heater's operation. Users can easily monitor the unit’s performance and make adjustments as needed. Additionally, these models come equipped with advanced safety features, including a built-in safety shut-off system and over-temperature protection, ensuring safe and reliable operation.

Both the GDVT and GDV series utilize A.O. Smith's innovative HydroJet® technology, which minimizes sediment buildup within the tank. This technology involves the strategic placement of an internal dip tube that maximizes water circulation, helping to extend the life of the water heater and maintain optimal performance over the years.

In summary, the A.O. Smith GDVT and GDV series water heaters are an excellent choice for those seeking a balance of efficiency, compact design, advanced technology, and enhanced safety. With their impressive energy ratings, user-friendly features, and cutting-edge technologies, these units are tailored to meet the demands of modern residential and commercial water heating solutions, ensuring a consistent supply of hot water while minimizing environmental impact.