A.O. Smith GDVT instruction manual Leakage Checkpoints, Service

Page 26

LEAKAGE CHECKPOINTS

SERVICE

If a condition persists or you are uncertain about the operation of the water heater contact a service agency.

Use this guide to check a “Leaking” water heater. Many sus- pected “Leakers” are not leaking tanks. Often the source of the water can be found and corrected.

If you are not thoroughly familiar with gas codes, your water heater, and safety practices, contact your gas supplier or quali- fied installer to check the water heater.

Read this manual first. Then before checking the water heater make sure the gas supply has been turned “OFF”, and never turn the gas “ON” before the tank is completely full of water.

Never use this water heater unless it is completely filled with wa- ter. To prevent damage to the tank, the tank must be filled with water. Water must flow from the hot water faucet before turning “ON” gas to the water heater.

A.Water at the blower assembly is water vapor which has con- densed out of the combustion products. This is caused by a problem in the vent. Contact the gas utility.

B.*Condensation may be seen on pipes in humid weather or pipe connections may be leaking.

C.*The anode rod fitting may be leaking (anode is located under the Blower Assembly).

D.Small amounts of water from temperature-pressure relief valve may be due to thermal expansion or high water pres- sure in your area.

E.*The temperature-pressure relief valve may be leaking at the tank fitting.

F.Water from a drain valve may be due to the valve being slightly opened.

G.*The drain valve may be leaking at the tank fitting.

H.Combustion products contain water vapor which can con- dense on the cooler surfaces of the tank. Droplets form and drip onto the burner or run on the floor. This is common at the time of start-up after installation and when incoming water is cold.

I.Water in the water heater bottom or on the floor may be from condensation, loose connections, or the relief valve. DO NOT replace the water heater until a full inspection of all pos- sible water sources is made and necessary corrective steps taken.

Leakage from other appliances, water lines, or ground seepage should also be checked.

*To check where threaded portion enters tank, insert cotton swab between jacket opening and fitting. If cotton is wet, follow “Draining” instructions in the “Periodic Maintenance” section and then remove fitting. Put pipe dope or Teflon tape on the threads and replace. Then follow “Filling the Water Heater” instructions in the “Installing the New Water Heater” section.

26

Image 26
Contents Residential GAS Water Heaters Safe INSTALLATION, USE and Service Important DefinitionsGeneral Safety Table of Contents IntroductionKeep Clear of ALL Obstructions Typical Installation GET to Know Your Water Heater Replacement PartsMixing Valve Usage Hotter Water can ScaldLocating the NEW Water Heater Facts to Consider about the LocationVent Termination Insulation BlanketsVentilation for Appliances Located in Confined Spaces Inspect Shipment Installing the NEW Water HeaterRequired Ability GeneralTEMPERATURE-PRESSURE Relief Valve Valve and Pipe Insulation if SuppliedGAS Piping Water Potable Heating and Space HeatingClosed Water System GAS Piping with Flexible Connector Venting High Altitude InstallationsSediment Traps Filling the Water Heater Combustion AIR and Ventilation Vent Terminal ClearancesHigh Rise Vent Arrangement Vent ConnectionsLocating Clearance Hole for Vent Standard Vent Arrangement Vent AssemblySecuring Vent Termination Assembly to the Exterior Wall Uncompressing the Corrugated TubingOffset Vent Arrangement MinimumTOP Knob Figure DTemperature Regulation Temperature RegulationStart UP Conditions For Your InformationExternal Damage Operational ConditionsAIR in HOT Water Faucets Pilot and Main Burner MaintenanceVenting System Inspection Draining Temperature & Pressure Relief ValveAnode ROD Maintenance Cathodic Protection AnodeDrain Valve Washer Replacement Service Leakage CheckpointsTroubleshooting Guidelines Problem Possible Causes CorrectionDrip from Relief Valve Slow HOT Water RecovERY Thermostat Fails toPage XCVT, Xcvx Series Tank PartsXCV, XCVL, XCVH, XVR Conditions and ExceptionsInstallation Information Service and Labor ResponsibilityClaim Procedure Limitation on Implied WarrantiesTennessee Waltz Parkway Ashland CITY, TN

GDV, GDVT specifications

A.O. Smith is a well-known name in the water heating industry, and its GDVT and GDV series of water heaters exemplify the company's commitment to quality, efficiency, and innovation. These models are designed to provide reliable hot water solutions for both residential and commercial needs, seamlessly integrating advanced technology and user-friendly features.

One of the main features of the GDVT and GDV series is their high energy efficiency ratings. These water heaters utilize advanced insulation and energy-saving technologies, allowing them to achieve impressive efficiency levels. The GDVT series, for instance, can achieve an Energy Factor (EF) rating of up to 0.96, making it an environmentally friendly choice that can significantly reduce energy bills. This high level of efficiency is a result of thoughtful engineering, including a highly insulated tank that minimizes heat loss.

Another standout characteristic of the GDVT and GDV series is their compact design. These models are built to fit into tight spaces, making them ideal for homes or businesses with limited installation areas. Despite their compact size, they maintain a large storage capacity, ensuring that users have access to consistent hot water. The GDVT series is particularly known for its vertical design, which allows for easy installation in smaller utility rooms or closets.

The GDV models feature a robust digital display that provides real-time information about the water heater's operation. Users can easily monitor the unit’s performance and make adjustments as needed. Additionally, these models come equipped with advanced safety features, including a built-in safety shut-off system and over-temperature protection, ensuring safe and reliable operation.

Both the GDVT and GDV series utilize A.O. Smith's innovative HydroJet® technology, which minimizes sediment buildup within the tank. This technology involves the strategic placement of an internal dip tube that maximizes water circulation, helping to extend the life of the water heater and maintain optimal performance over the years.

In summary, the A.O. Smith GDVT and GDV series water heaters are an excellent choice for those seeking a balance of efficiency, compact design, advanced technology, and enhanced safety. With their impressive energy ratings, user-friendly features, and cutting-edge technologies, these units are tailored to meet the demands of modern residential and commercial water heating solutions, ensuring a consistent supply of hot water while minimizing environmental impact.