A.O. Smith GDVT instruction manual Keep Clear of ALL Obstructions

Page 5

INSTALLATION REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS

For all side wall terminated, horizontally vented power vent, direct vent, and power direct vent gas fueled water heaters installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:

INSTALLATION OF CARBON MONOXIDE DETECTORS At the time of installation of the side wall horizontal vented gas fu- eled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each ad- ditional level of the dwelling, building or structure served by the sidewall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors.

In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements provided that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.

APPROVED CARBON MONOXIDE DETECTORS Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and CSA certified.

SIGNAGE A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appli- ance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW.

KEEP CLEAR OF ALL OBSTRUCTIONS.”

INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a) 1 through 4.

EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:

1.The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and

2.Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwell- ing, building, or structure used in whole or in part for residential purposes.

MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

1.Detailed instructions for the installation of the venting system design or the venting system components; and

2.A complete parts list for the venting system design or venting system.

MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies “special venting systems,” the following requirements shall be satisfied by the manufacturer:

1.The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and

2.The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.

A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all vent- ing instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

5

Image 5
Contents Residential GAS Water Heaters Important Definitions Safe INSTALLATION, USE and ServiceGeneral Safety Introduction Table of ContentsKeep Clear of ALL Obstructions GET to Know Your Water Heater Replacement Parts Typical InstallationHotter Water can Scald Mixing Valve UsageFacts to Consider about the Location Locating the NEW Water HeaterVent Termination Insulation BlanketsVentilation for Appliances Located in Confined Spaces Required Ability Installing the NEW Water HeaterInspect Shipment GeneralValve and Pipe Insulation if Supplied TEMPERATURE-PRESSURE Relief ValveGAS Piping Water Potable Heating and Space HeatingClosed Water System GAS Piping with Flexible Connector Venting High Altitude InstallationsSediment Traps Filling the Water Heater Vent Terminal Clearances Combustion AIR and VentilationHigh Rise Vent Arrangement Vent ConnectionsLocating Clearance Hole for Vent Securing Vent Termination Assembly to the Exterior Wall Vent AssemblyStandard Vent Arrangement Uncompressing the Corrugated TubingMinimum Offset Vent ArrangementFigure D TOP KnobTemperature Regulation Temperature RegulationExternal Damage For Your InformationStart UP Conditions Operational ConditionsAIR in HOT Water Faucets Pilot and Main Burner MaintenanceVenting System Inspection Anode ROD Maintenance Temperature & Pressure Relief ValveDraining Cathodic Protection AnodeDrain Valve Washer Replacement Leakage Checkpoints ServiceProblem Possible Causes Correction Troubleshooting GuidelinesERY Slow HOT Water RecovDrip from Relief Valve Thermostat Fails toPage XCV, XCVL, XCVH, XVR Series Tank PartsXCVT, Xcvx Conditions and ExceptionsClaim Procedure Service and Labor ResponsibilityInstallation Information Limitation on Implied WarrantiesTennessee Waltz Parkway Ashland CITY, TN

GDV, GDVT specifications

A.O. Smith is a well-known name in the water heating industry, and its GDVT and GDV series of water heaters exemplify the company's commitment to quality, efficiency, and innovation. These models are designed to provide reliable hot water solutions for both residential and commercial needs, seamlessly integrating advanced technology and user-friendly features.

One of the main features of the GDVT and GDV series is their high energy efficiency ratings. These water heaters utilize advanced insulation and energy-saving technologies, allowing them to achieve impressive efficiency levels. The GDVT series, for instance, can achieve an Energy Factor (EF) rating of up to 0.96, making it an environmentally friendly choice that can significantly reduce energy bills. This high level of efficiency is a result of thoughtful engineering, including a highly insulated tank that minimizes heat loss.

Another standout characteristic of the GDVT and GDV series is their compact design. These models are built to fit into tight spaces, making them ideal for homes or businesses with limited installation areas. Despite their compact size, they maintain a large storage capacity, ensuring that users have access to consistent hot water. The GDVT series is particularly known for its vertical design, which allows for easy installation in smaller utility rooms or closets.

The GDV models feature a robust digital display that provides real-time information about the water heater's operation. Users can easily monitor the unit’s performance and make adjustments as needed. Additionally, these models come equipped with advanced safety features, including a built-in safety shut-off system and over-temperature protection, ensuring safe and reliable operation.

Both the GDVT and GDV series utilize A.O. Smith's innovative HydroJet® technology, which minimizes sediment buildup within the tank. This technology involves the strategic placement of an internal dip tube that maximizes water circulation, helping to extend the life of the water heater and maintain optimal performance over the years.

In summary, the A.O. Smith GDVT and GDV series water heaters are an excellent choice for those seeking a balance of efficiency, compact design, advanced technology, and enhanced safety. With their impressive energy ratings, user-friendly features, and cutting-edge technologies, these units are tailored to meet the demands of modern residential and commercial water heating solutions, ensuring a consistent supply of hot water while minimizing environmental impact.