TEMPERATURE & PRESSURE RELIEF VALVE

At least once a year, the temperature and pressure relief valve, Figure 1, must be checked to ensure that it is in operating condi- tion. Lift the lever at the top of the valve several times until the valve seats properly and operates freely.

If water does not flow, remove the valve and inspect for obstruc- tions or corrosion. Have a qualified servicer replace with a new valve of the recommended size as necessary. Do not attempt to repair the valve, as this could result in improper operation and a tank explosion. In areas with poor water conditions, it may be necessary to inspect the T&P valve more frequently.

THE WATER PASSING OUT OF THE VALVE DURING THIS CHECKING OPERATION MAY BE EXTREMELY HOT. AVOID CONTACT AND DISCHARGE SAFELY TO PREVENT WATER DAMAGE.

DRAINING

If the heater is to be shut off and exposed to freezing tempera- tures, it must be drained. Water, if left in the tank and allowed to freeze, will damage the heater.

Turn off the gas and cold water inlet valve to the heater, Figure 1.

Open a nearby hot water faucet and the heater drain valve.

BE CAREFUL TO GRASP THE DRAIN VALVE HANDLE SO THAT THE HAND IS NOT EXPOSED TO HOT WATER. IF DESIRED, A HOSE MAY BE CONNECTED TO THE DRAIN VALVE TO CARRY THE WATER AWAY.

The water CAN BE HOT.

The drain valve must be left open during the shutdown pe- riod.

To restart heater, refer to the FILLING instructions under OP-

ERATION.

Periodically open the drain valve and allow the water to run until it flows clean. This will help prevent sediment build-up in the tank.

It is normal for lime and scale deposits to form within the tank. Such deposits will not be removed by periodic draining. It is necessary to chemically delime the affected parts in water areas where such deposits are encountered. Contact your dealer or plumber for deliming information.

CATHODIC PROTECTION - ANODE

The anode rod within the tank is designed to be slowly con- sumed cathodically, minimizing corrosion in the glass-lined tank. A hydrogen sulfide (rotten egg) odor may result if water contains high sulfate and/or minerals. Chlorinating the water supply should minimize the problem. (See EXTENDED NON-

USE PERIODS).

NOTE: Anode must remain installed (except for inspection) to avoid shortening tank life. See LIMITED WARRANTY. Replace as necessary.

ANODE ROD MAINTENANCE

The anode rod is used to protect the tank from corrosion. Most hot water tanks are equipped with an anode rod. The submerged rod sacrifices itself to protect the tank. Instead of corroding the tank, water ions attack and eat away the anode rod. This does not affect the water’s taste or color. The rod must be maintained to keep the tank in operating condition.

Anode deterioration depends on water conductivity, not neces- sarily water condition. A corroded or pitted anode rod indicates high water conductivity and should be checked and/or replaced more often than an anode rod that appears to be intact. Re- placement of a depleted anode rod can extend the life of your water heater. Inspection should be conducted by a qualified technician, and at a minimum should be checked annually after the warranty period.

23

Image 23
Contents Residential GAS Water Heaters Important Definitions Safe INSTALLATION, USE and ServiceGeneral Safety Introduction Table of ContentsGET to Know Your Water Heater Replacement Parts Typical InstallationHotter Water can Scald Mixing Valve UsageFacts to Consider about the Location Locating the NEW Water HeaterVent Termination Insulation BlanketsVentilation for Appliances Located in Confined Spaces General Installing the NEW Water HeaterRequired Ability Inspect ShipmentValve and Pipe Insulation if Supplied TEMPERATURE-PRESSURE Relief ValveGAS Piping Water Potable Heating and Space HeatingClosed Water System GAS Piping with Flexible Connector Venting High Altitude InstallationsSediment Traps Filling the Water Heater Vent Terminal Clearances Combustion AIR and VentilationHigh Rise Vent Arrangement DV Termination Safety CoverVent Connections Locating Clearance Hole for VentUncompressing the Corrugated Tubing Vent AssemblySecuring Vent Termination Assembly to the Exterior Wall Standard Vent ArrangementOffset Vent Arrangement Figure a Temperature Regulation Temperature RegulationOperational Conditions For Your InformationExternal Damage Start UP ConditionsAIR in HOT Water Faucets Pilot and Main Burner MaintenanceVenting System Inspection Cathodic Protection Anode Temperature & Pressure Relief ValveAnode ROD Maintenance DrainingDrain Valve Washer Replacement Leakage Checkpoints ServiceProblem Possible Causes Correction Troubleshooting GuidelinesThermostat Fails to Slow HOT Water RecovERY Drip from Relief ValvePage Conditions and Exceptions Series Tank PartsXCV, XCVL, XCVH, XVR XCVT, XcvxLimitation on Implied Warranties Service and Labor ResponsibilityClaim Procedure Installation InformationTennessee Waltz Parkway Ashland CITY, TN

186589-004, GDVT-50, GDV-75, GDV-40, GDV-50 specifications

A.O. Smith is a recognized name in the water heating industry, known for its reliable and efficient water heaters. Among its notable products are the GDV-50, GDV-40, GDV-75, GDVT-50, and 186589-004 models. These water heaters offer enhanced performance, energy efficiency, and modern technologies suited for residential and commercial applications.

The GDV series includes the GDV-50, GDV-40, and GDV-75 models, which feature a robust design typically made from high-quality materials to ensure longevity. These units come equipped with advanced insulation, which minimizes heat loss and increases efficiency, making them excellent choices for households with varying hot water needs.

The GDV-50 model boasts a tank capacity of 50 gallons, making it suitable for medium to large households. It features a powerful heating element that heats water quickly, providing ample hot water for daily use. Meanwhile, the GDV-40 is designed for smaller households with a 40-gallon capacity. This model strikes a balance between size and efficiency, catering to lighter hot water demands while maintaining excellent performance.

For larger households, the GDV-75 provides a 75-gallon capacity, ensuring that even the most demanding hot water applications can be met with ease. This model is particularly ideal for families that require hot water in large quantities or at peak times.

The GDVT-50 is a versatile model that features advanced technology, such as an integrated digital display that allows users to monitor and adjust settings easily. This offers greater control over temperature settings and energy usage, making it not only convenient but also more energy-efficient.

The A.O. Smith 186589-004 is an accessory designed for specific model enhancements that improve overall performance and safety. It may include additional safety features, such as high-temperature limit switches and automatic shut-off mechanisms that provide peace of mind for users.

All these models are equipped with A.O. Smith’s innovative technologies, including advanced thermostat controls and durable components designed to withstand frequent use. They typically come with generous warranties, underscoring the manufacturer's commitment to quality and customer satisfaction.

In summary, A.O. Smith water heaters, particularly the GDV-50, GDV-40, GDV-75, GDVT-50, and 186589-004, are built for efficiency, reliability, and performance. With various capacities and the latest technologies, they cater to the diverse needs of homeowners and businesses, ensuring that hot water is always available when needed.