INSTALLING THE NEW WATER HEATER

REQUIRED ABILITY

INSTALLATION OR SERVICE OF THIS WATER HEATER REQUIRES ABILITY EQUIVALENT TO THAT OF A LICENSED TRADESMAN IN THE FIELD INVOLVED. PLUMBING, AIR SUPPLY, VENTING AND GAS SUPPLY ARE REQUIRED.

INSPECT SHIPMENT

There may be hidden damage caused in transit. Check to be certain all parts of the venting system, as listed below, are present. CAUTION!!! IF THERE ARE ANY DAMAGED

PARTS, DO NOT INSTALL THIS WATER HEATER. REPORT ANY SHORTAGE TO YOUR DISTRIBUTOR OR DAMAGE TO YOUR CARRIER.

GENERAL

The installation must conform to these instructions and the local code authority having jurisdiction. In the absence of local codes, the installation must comply with the current editions of the “Nat- ural Gas and Propane Installation Code” CAN/CSA-B149.1. The code is available from the Canadian Standards Association, 5060 Spectrum Way, Mississauga, Ontario, Canada, L4W 5N6.

WATER PIPING

HOTTER WATER CAN SCALD:

Water heaters are intended to produce hot water. Water heated to a temperature which will satisfy space heating, clothes wash- ing, dish washing, cleaning and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physically/men- tally handicapped. If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap, then you must take special precautions. In addition to using the low- est possible temperature setting that satisfies your hot water needs, a means such as a *mixing valve, should be used at the hot water taps used by these people or at the water heater, see Figure 2. Valves for reducing point of use temperature by mixing cold and hot water are also available:

Consult a Qualified Installer or Service Agency. Follow man- ufacturer’s instructions for installation of the valves. Before changing the factory setting on the thermostat, read the “Tem- perature Regulation” section in this manual.

This water heater shall not be connected to any heating systems or component(s) used with a non-potable water heating appli- ance.

All piping components connected to this unit for space heating applications shall be suitable for use with potable water.

Toxic chemicals, such as those used for boiler treatment shall not be introduced into this system.

When the system requires water for space heating at tem- peratures higher than required for domestic water purposes, a *mixing valve must be installed. Please refer to Figure 2 for suggested piping arrangement.

Water supply systems may, because of such events as high line pressure, frequent cut-offs, the effects of water hammer among others, have installed devices such as pressure reducing valves, check valves, back flow preventers, etc. to control these types of problems. When these devices are not equipped with an internal by-pass, and no other measures are taken, the devices cause the water system to be closed. As water is heated, it expands (thermal expansion) and closed systems do not allow for the expansion of heated water.

The water within the water heater tank expands as it is heated and increases the pressure of the water system. If the relieving point of the water heater’s temperature-pressure relief valve is reached, the valve will relieve the excess pressure. The temperature-pressure relief valve is not intended for the constant relief of thermal expansion. This is an unacceptable condition and must be corrected.

It is recommended that any devices installed which could create a closed system have a by-pass and/or the system have an ex- pansion tank to relieve the pressure built by thermal expansion in the water system. Expansion tanks are available for ordering through a local plumbing contractor. Contact the local water supplier and/or a service agency for assistance in controlling these situations.

NOTE: To protect against untimely corrosion of hot and cold water fittings, it is strongly recommended that di-electric unions or couplings be installed on this water heater when connected to copper pipe.

All gas piping must comply with local codes and ordinances or with the “Natural Gas and Propane Installation Code” CAN/ CSA-B149.1 whichever applies. Copper and brass tubing and fittings (except tin lined copper tubing) shall not be used.

9

Image 9
Contents Residential GAS Water Heaters Important Definitions Safe INSTALLATION, USE and ServiceGeneral Safety Introduction Table of ContentsGET to Know Your Water Heater Replacement Parts Typical InstallationHotter Water can Scald Mixing Valve UsageFacts to Consider about the Location Locating the NEW Water HeaterInsulation Blankets Ventilation for Appliances Located in Confined SpacesVent Termination Required Ability Installing the NEW Water HeaterInspect Shipment GeneralValve and Pipe Insulation if Supplied TEMPERATURE-PRESSURE Relief ValveWater Potable Heating and Space Heating Closed Water SystemGAS Piping GAS Piping with Flexible Connector High Altitude Installations Sediment Traps Filling the Water HeaterVenting Vent Terminal Clearances Combustion AIR and VentilationVent Connections DV Termination Safety CoverLocating Clearance Hole for Vent High Rise Vent ArrangementSecuring Vent Termination Assembly to the Exterior Wall Vent AssemblyStandard Vent Arrangement Uncompressing the Corrugated TubingOffset Vent Arrangement Figure a Temperature Regulation Temperature RegulationExternal Damage For Your InformationStart UP Conditions Operational ConditionsAIR in HOT Water Faucets Maintenance Venting System InspectionPilot and Main Burner Anode ROD Maintenance Temperature & Pressure Relief ValveDraining Cathodic Protection AnodeDrain Valve Washer Replacement Leakage Checkpoints ServiceProblem Possible Causes Correction Troubleshooting GuidelinesERY Slow HOT Water RecovDrip from Relief Valve Thermostat Fails toPage XCV, XCVL, XCVH, XVR Series Tank PartsXCVT, Xcvx Conditions and ExceptionsClaim Procedure Service and Labor ResponsibilityInstallation Information Limitation on Implied WarrantiesTennessee Waltz Parkway Ashland CITY, TN

186589-004, GDVT-50, GDV-75, GDV-40, GDV-50 specifications

A.O. Smith is a recognized name in the water heating industry, known for its reliable and efficient water heaters. Among its notable products are the GDV-50, GDV-40, GDV-75, GDVT-50, and 186589-004 models. These water heaters offer enhanced performance, energy efficiency, and modern technologies suited for residential and commercial applications.

The GDV series includes the GDV-50, GDV-40, and GDV-75 models, which feature a robust design typically made from high-quality materials to ensure longevity. These units come equipped with advanced insulation, which minimizes heat loss and increases efficiency, making them excellent choices for households with varying hot water needs.

The GDV-50 model boasts a tank capacity of 50 gallons, making it suitable for medium to large households. It features a powerful heating element that heats water quickly, providing ample hot water for daily use. Meanwhile, the GDV-40 is designed for smaller households with a 40-gallon capacity. This model strikes a balance between size and efficiency, catering to lighter hot water demands while maintaining excellent performance.

For larger households, the GDV-75 provides a 75-gallon capacity, ensuring that even the most demanding hot water applications can be met with ease. This model is particularly ideal for families that require hot water in large quantities or at peak times.

The GDVT-50 is a versatile model that features advanced technology, such as an integrated digital display that allows users to monitor and adjust settings easily. This offers greater control over temperature settings and energy usage, making it not only convenient but also more energy-efficient.

The A.O. Smith 186589-004 is an accessory designed for specific model enhancements that improve overall performance and safety. It may include additional safety features, such as high-temperature limit switches and automatic shut-off mechanisms that provide peace of mind for users.

All these models are equipped with A.O. Smith’s innovative technologies, including advanced thermostat controls and durable components designed to withstand frequent use. They typically come with generous warranties, underscoring the manufacturer's commitment to quality and customer satisfaction.

In summary, A.O. Smith water heaters, particularly the GDV-50, GDV-40, GDV-75, GDVT-50, and 186589-004, are built for efficiency, reliability, and performance. With various capacities and the latest technologies, they cater to the diverse needs of homeowners and businesses, ensuring that hot water is always available when needed.