A.O. Smith BFM - 120, BFM - 100 manual Gas control for BFM

Page 37

is

Gas control for BFM 120

Legend

1. burner pressure regulator

3.burner pressure regulator adjustment screw

6.supply pressure test nipple

7.gas control

8.manifold test nipple

6

7

3

8

1

IMD-0257 R1

1.Isolate the appliance from the power supply (10.3 "Isolating the appliance from the mains").

2.There are two test nipples on the gas control. Test nipple (6) is used to check the supply pressure. The other test nipple on the gas control is not used. The manifold test nipple (8) is used to measure the burner pressure.

Sealing screws are located inside the test nipples. Loosen both sealing screws by a few turns. Do not completely loosen them; they can be difficult to re-tighten.

3.Connect a pressure gauge to the manifold test nipple (8).

4.Open the gas supply and bleed the air from the mains gas supply via test nipple (6).

5.Connect a pressure gauge to the manifold test nipple (6) when gas starts to flow from this nipple.

6.Switch on the power to the appliance using the isolator on the appliance.

7.Set the control thermostat to the maximum temperature and start the appliance running by setting the ON/OFF switch to position I.

8.The heating cycle will start, and after a short time the burner tray will ignite.

9.After the burner tray has ignited, wait approximately 1 minute before reading the dynamic pressures.

10.Use the pressure gauge to read the supply pressure at test nipple (6). Refer to the gas data table (3.4.3 "Gas data").

Note

Consult the mains gas supply company if the supply pressure is not correct.

Instruction manual BFM

37

Image 37
Contents Page Page Trademarks Read this manual carefullyLiability More informationGis Table of contents Performing maintenance TroubleshootingWarranty certificate Electrical diagramAbout the appliance IntroductionWhat to do if you smell gas Regulations Symbol Target group Maintenance Forms of notation Target groupsIntroduction Document Overview of thisChapter Target groups Description Gis General working Working principle of the appliancePrinciple Appliance Working principle of the appliance Appliances heating cycle Protection for the appliance Pressure switch Water temperature protectionFlame probe Protection DescriptionUnvented installation Safety of the instal- lationVented installation 3 T&P valveGis Air humidity and ambient temperature InstallationAir humidity and ambient temperature PackagingMaximum floor load InstallationWater composition Working clearancesTechnical specifica- tions Plan and elevation of the appliance Dimensions of the applianceDimens Description General and electrical specificationsBFM100 BFM120 Ion UnitDescription Unit Gas dataNatural gas G20 20 mbar LP gas data G30 30 mbar butaneInstallation diagram Installation diagramCold water side Water connections, VentedRecirculation pipe Hot water sideCirculation pipe Water connections, Unvented See C in the installation diagram 3.5 Installation diagramGas connection Circulation pipeAir supply and flue Introduction Installing chimney flue components for BFM 30, 50Subject Description Concentric wall flue terminal BFMConcentric roof flue terminal BFM 30, 50 Installing chimney flue components for BFM 100 C33 concentric roof flue terminal specifications BFM 30, 50Concentric wall flue terminal BFM100 M2000 MDV SCC C13 concentric wall flue terminal specifications BFM 100Concentric roof flue terminal BFM 100 Electrical connection 11 C33 concentric roof flue terminal specifications BFM 100Mains power Fan Alarm Off Connecting the mains powerGas control for BFM 30 through Checking the supply pressure and burner pressureGas control for BFM BFM BFM 30, 50, 80Conversion Conversion to a different gas categoryConversion to a different gas category Orifice replacementPage Conversion to a different gas category Filling Filling Draining Draining Draining unvented installationsDraining vented installations Gis Control panel ON/OFF switchExplanation of icons Control thermostatControl panel Burner control reset buttonStatus of the appliance Error conditionsOperating modes Status of the appliance Starting the appliance Starting and runningAppliances heating cycle Starting and running Shutting down Shutting down the appliance for a brief period OFF modeIsolating the appliance from the mains Shutting the appliance down for a long periodShutting down Control thermostat 7.5 Control thermostat TroubleshootingSymptom Cause Solution Remark Gas smell Troubleshooting general errorsWater leakage Explosive ignitionSymptom Cause Solution Remark Insufficient hot water Troubleshooting insufficient hot waterTroubleshooting No hot water Cycle Symptom Cause Solution RemarkPage Introduction Preparation for maintenance Performing maintenancePerforming maintenance Descaling and cleaning the tankWater-side mainte- nance 12.3.1 Checking the anodesIMD-0235 R2 Clean the orifices Clean the burnersGas-side mainte- nance 12.4.1 Checking the flue baffles Finalising mainte- nance13.1 General warranty Warranty certificate13.2 Tank warranty Conditions for Instal- lation and useWarranty certificate Electrical diagram Electrical diagram BFM Electrical DiagramOptional Components Electrical diagram Index Index 0306