11.2 Troubleshooting: general errors
Warning
Maintenance may only be performed by a qualified service and maintenance engineer.
General errors
Symptom | Cause | Solution |
| Remark | |
|
|
|
|
|
|
Gas smell | Gas leak |
|
|
| Warning |
| Warning | ||||
|
|
|
| Contact your installation engineer or local gas company | |
|
|
| Close the main gas valve immediately. |
| immediately. |
|
|
| Warning |
|
|
|
|
| Do not operate any switches. |
|
|
|
|
| Warning |
|
|
|
|
| No naked flames. |
|
|
|
|
| Warning |
|
|
|
|
| Ventilate the boiler room. |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Water leakage | Leakage from a water | Tighten the threaded connection |
| If the leak persists, consult your installation engineer | |
| connection (threaded) |
|
|
|
|
| Leakage from another | Trace the leak |
|
| |
| nearby water appliance |
|
|
|
|
| or pipe segment |
|
|
|
|
|
|
|
|
| |
| Leakage from the | Consult the supplier and/or manufacturer |
|
| |
| appliance's tank |
|
|
|
|
| Condensation | Before drawing (too much) tap water, wait until the water in the |
|
| |
|
| boiler has reached the set temperature. |
|
| |
|
|
|
|
| |
Explosive ignition | Incorrect supply | Set the correct supply pressure and/or burner |
| If ignition is not improved, consult your installation engineer. | |
| pressure and/or burner | pressure. (3.11 "Checking the supply pressure and burner |
|
| |
Poor flame profile | pressure | pressure") |
|
| |
| Contaminated burner | Clean the burner(s) (12.4.2 "Clean the burner(s)") |
|
| |
|
|
|
|
| |
| Contaminated orifice | Clean the orifice(s) (12.4.3 "Clean the orifice(s)") |
|
| |
|
|
|
|
| |
| Inadequate air supply | Improve the air supply by providing better ventilation in the boiler |
|
| |
|
| room. |
|
|